Henny Penny 680 KFC Do not Disassemble or Modify this Vavle, Pressure Gauge, Calibration Steps

Page 57

Henny Penny

 

Model 680

5-18. REMOVAL & CLEANING

3.

Clean inside of the elbow with hot water.

OF SAFETY VALVE

 

NOTE

(Continued)

 

Turn the relief valve towards the left side of the fryer

 

 

when reinstalling relief valve.

 

4.

Immerse the safety relief valve in soapy water for 24

 

 

hours. Use a 1 to 1 dilution rate. The valve cannot be

 

 

disassembled. It is factory preset to open at 14 1⁄2 pounds

 

 

of pressure. If it does not open or close, replace it!

 

 

DO NOT DISASSEMBLE OR MODIFY THIS VAVLE!

 

 

Tampering with this valve could cause serious injuries and

 

 

also voids agency approvals and appliance warranty.

5-19. PRESSURE GAUGE

 

 

Calibration Steps

Recalibrate the pressure gauge if it is out of adjustment.

PRESSURE GAUGE

1.

Remove the rim and glass.

 

2.

If the indication hand shows a pressure or vacuum reading

 

 

when it should stand at “0”, turn the recalibrator screw in

 

 

the same direction in the indicating hand is to be moved

 

 

until the hand stands at proper “0” position.

 

3.

Replace the rim and glass.

Cleaning Steps

1.

Remove the gauge and check inside the pipefittings from

 

 

dead weight body. Make certain fittings are clean and

 

 

open.

 

2.

Clean and reinstall the gauge.

5-16

1005

Image 57
Contents Page Henny Penny 8 Head GAS Pressure Fryer SpecificationsPage Page Limited Warranty for Henny Penny Appliances Introduction Section Pressure Fryer IntroductionPressure HeatPage Page Page Prop UP a Ramp for Each Caster on the Selected Side Insert Page Page Page ALL STR N Unit again after installation Shortening MAY Start UP Procedure Lever Is not to be Pulled Page Page Push handle back and raise lid Lo Mode Switches IndicatorsCool Mode Melt Cycle OperationHeat Light will illuminate whenever the control calls for Page Refer to KFC’s Standards Library on cleaning instructions Page 397 Connecw Hj i’.,‘i ,e.*f Page Product Color Not Correct Too Dark Spotted Rancid Taste Shortening Too old Pressure will not Eplace pressure plate Replace module Heating of shortening too slow Or boil Water Shortening Ing over Gasket coming out of lid Pressure System Page Page Pump Position Check from Page Panel Henny Penny Complete ControlPressure Regulation Every 90 daysPage Page Page Pressure PAD LID Counterweight CONT’DLID Adjustment Hertz Page Solenoid Valve ReplacementSeat Operating Control ValveRemoval & Cleaning Do not Manuallyactivate the SafetySafety Valve Operating ControlDo not Disassemble or Modify this Vavle Pressure GaugeCalibration Steps Page Page Page Page Page Page Page Page Page Using 3/8 socket, remove nut securing ground wire If no red glow is seen, proceed with the following Page Page Page Epyg-ui nuebq plea ewy Page Page Page Page Product One Part PER Number Description Assy UnitsLatch Plate PANEL, Right Side Page Not Avail Page Part PER Number Description Counterweight BARCable CarriageHenny Penny Model 1005 Units Part PER Number Description Assy LinkageassemblyLID Instruction Label CAM Slide FillerPage 705 Page Fitting Connector Dead WeightPressure Gauge Pipe ELBOW, 1/4Page SUPPORT, Drain ROD LINK, Drain RODBRACKET, HI-LIMIT HI-LIMITPage Units Smooth and Rounded Edge of Blade CORE, Disc Assembly Solenoid ValveassemblyCOVER, Coil Housing HOUSING, CoilHead GAS Cooker I I SIE IAy--4A-+-7 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 SMS Programming IfApplicableCode After the load compensation, press and release the Func SMS Special Program Review UsageMode Factory Presets F/C, Gas/Electric, Speaker Volume Reset UsageMode Speaker Frequency, Codes, Initialize SystemTech I/O Mode Appliance TestHeat Control Press and release the Function button and MELT, Mode