Henny Penny 680 KFC manual After the load compensation, press and release the Func

Page 105

Henny Penny

 

Model 680

SMS PROGRAMMING

8.

After the load compensation, press and release the Func-

(Continued)

 

tion button. “PROP” and “CONTROL” shows on the

 

 

left side of the display and the factory preset proportional

 

 

control temperature shows on the right side of the display.

 

9.

After the proportional control, press and release the

 

 

Function button. “ALM 1” and “TIME” flashes in

 

 

the left side of the display, and the first alarm time shows

 

 

on the right side of the display. To change the time the

 

 

alarm sounds, press the appropriate product buttons to set

 

 

the time. Ex: Press 1,0,0,0. 10:00 will flash on the right

 

 

side of the display, which means when the timer counts

 

 

down to 10 minutes, an alarm will sound.

 

10.

After alarm is set, press and release the Function

 

 

button. “ALM 1”, “SELF-’’, and “CANCEL” flashes

 

 

in the left side of the display and “YES” or “NO” shows

 

 

on the right side of the display. The yes and no can be

 

 

toggled by pressing any of the product buttons, (l -0).

 

 

“YES” means the alarm tone will automatically stop after

 

 

several beeps. “NO” means someone must manually

 

 

press the appropriate product button to stop the alarm

 

 

tone.

 

11.

Repeat steps 9 and 10 for alarms 2 and 3.

 

12.

After alarm 3 is set, press and release the Function

 

 

button. “FILTER” and “CYCLES” show on the left side

 

 

of the display and the filter cycle value is on the right side

of the display. The value is the number of cook cycles that must completed before the control signals the opera- tor that the shortening needs filtered

6-32

1005

Image 105
Contents Page Henny Penny 8 Head GAS Pressure Fryer SpecificationsPage Page Limited Warranty for Henny Penny Appliances Introduction Section Pressure Fryer IntroductionPressure HeatPage Page Page Prop UP a Ramp for Each Caster on the Selected Side Insert Page Page Page ALL STR N Unit again after installation Shortening MAY Start UP Procedure Lever Is not to be Pulled Page Page Push handle back and raise lid Lo Mode Switches IndicatorsCool Mode Melt Cycle OperationHeat Light will illuminate whenever the control calls for Page Refer to KFC’s Standards Library on cleaning instructions Page 397 Connecw Hj i’.,‘i ,e.*f Page Product Color Not Correct Too Dark Spotted Rancid Taste Shortening Too old Pressure will not Eplace pressure plate Replace module Heating of shortening too slow Or boil Water Shortening Ing over Gasket coming out of lid Pressure System Page Page Pump Position Check from Page Panel Henny Penny Complete ControlPressure Regulation Every 90 daysPage Page Page Pressure PAD LID Counterweight CONT’DLID Adjustment Hertz Page Solenoid Valve ReplacementSeat Operating Control ValveRemoval & Cleaning Do not Manuallyactivate the SafetySafety Valve Operating ControlDo not Disassemble or Modify this Vavle Pressure GaugeCalibration Steps Page Page Page Page Page Page Page Page Page Using 3/8 socket, remove nut securing ground wire If no red glow is seen, proceed with the following Page Page Page Epyg-ui nuebq plea ewy Page Page Page Page Product One Part PER Number Description Assy UnitsLatch Plate PANEL, Right Side Page Not Avail Page Part PER Number Description Counterweight BARCable CarriageHenny Penny Model 1005 Units Part PER Number Description Assy LinkageassemblyLID Instruction Label CAM Slide FillerPage 705 Page Fitting Connector Dead WeightPressure Gauge Pipe ELBOW, 1/4Page SUPPORT, Drain ROD LINK, Drain RODBRACKET, HI-LIMIT HI-LIMITPage Units Smooth and Rounded Edge of Blade CORE, Disc Assembly Solenoid ValveassemblyCOVER, Coil Housing HOUSING, CoilHead GAS Cooker I I SIE IAy--4A-+-7 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 SMS Programming IfApplicableCode After the load compensation, press and release the Func SMS Special Program Review UsageMode Factory Presets F/C, Gas/Electric, Speaker Volume Reset UsageMode Speaker Frequency, Codes, Initialize SystemTech I/O Mode Appliance TestHeat Control Press and release the Function button and MELT, Mode