Henny Penny |
|
| Model 680 |
|
| Should the Control Panel not operate, replace the panel as follows: | |
| |||
PANEL - HENNY PENNY |
| 1. | Remove electrical power supplied to the fryer. |
|
| ||
|
|
| Place the Power/Pump Switch in the “OFF” position, and |
|
|
| unplug the power cord and/or turn off the wall circuit breaker, |
|
|
| or electrical shock could result. |
|
| 2. | Remove the two screws securing the Control Panel and lift |
|
|
| panel up and out. |
|
| 3. | Unplug the connectors going to the Control Board. |
|
| 4. | Install new Control Panel. |
|
|
| When plugging connectors into new Control Panel, be sure |
|
|
| connectors are |
|
|
| plugged in backwards, or damage to the board could result. |
|
|
| |
|
| The Henny Penny Fryer uses pressure as one of the components of | |
|
| the cooking process. Once the lid is sealed to the cookpot, and the | |
|
| solenoid valve closes, a deadweight valve maintains the correct | |
|
| pressure in the cookpot. | |
|
| The lid has minimal and limited maintenance and repair procedures, | |
|
| which are addressed in the following sections. | |
|
| The following is a routine maintenance schedule for the Lid: | |
|
| Every 90 days | |
|
| • | Clean and reverse lid gasket |
|
| Yearly Inspection | |
|
| • | Remove and clean safety relief valve |
|
| • | Check Lid Gasket for splitting and tears - replace if necessary |
|
| • | Check Pressure Pads for wear - rotate if necessary |
|
| • | Check Cam Slide Guides - replace if worn or broken |
|
| • | Check Lid Rollers - replace if cracked or damaged. |
1005 |