Agilent Technologies E1441A manuals
Kitchen Appliance > Oven
When we buy new device such as Agilent Technologies E1441A we often through away most of the documentation but the warranty.
Very often issues with Agilent Technologies E1441A begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Oven Agilent Technologies E1441A is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Oven on our side using links below.
Agilent Technologies E1441A User Service
206 pages 3.66 Mb
Where to Find it - Online and Printed Information: Agilent E1441A Function/Arbitrary Waveform GeneratorUser/Service and SCPI Programming Manual *E1441-90003*3 ContentsAgilent E1441A Function/Arbitrary Waveform Gene rato r Users Man ualEdition 37 7Certification AGILENT TECHNOLOGIES WARRANTY STATEMENT U.S. Government Restricted Rights 8 8 Safety Symbols WARNINGS Documentation History Trademarks 9 DECLARATION OF CONFORMITYChapter 1 13 Agilent E1441A Function/Arbitrary Waveform Generator Module Setup19 Agilent E1441A Application Information65 Agilent E1441A SCPI Command Reference Command Index by Function 70 Command FundamentalsCommon Command Format SCPI Command FormatCommand Separator Abbreviated Commands Implied Commands Parameters 71 Linking Commands 72 SCPI Command Reference73 CALibrationSubsystem Syntax CALibration?Comments Execution of this command begins the electronic adjustment for the function :COUNt?Comments *RST does not change the calibration count stored in non-volatile memory. Example 74 :SECure:CODEComments The security code is set to "HP_E1441" when the function generator is shipped :SECure:STATe 76 :STRing? :VALueComment *RST does not affect the calibration value. Example :VALue? 77 DATA Subsystem Syntax VOLATILEComments The values -1 and +1 correspond to the peak values of the waveform. 78 :DAC VOLATILEComments The values -2047 and +2047 correspond to the peak values of the waveform. Downloading a Binary Block of Data 79 :ATTRibute:AVERage?Parameters The arb name may contain up to 8 characters. The first character must be a Comments If you query a waveform t hat is not currently stored in memo ry, a+785, :ATTRibute:CFACtor?Parameters The arb name may contain up to 8 characters. The first character must be a 80 Comments If you query a waveform t hat is not currently stored in m emory, a +785, :ATTRibute:POINts?Parameters The arb name may contain up to 8 characters. The first character must be a Comments If you query a waveform t hat is not currently stored in m emory, a +785, :ATTRibute:PTPeak?Parameters The arb name may contain up to 8 characters. The first character must be a Comments This command returns a value between 0 and +1.0, with +1.0 indicating 81 :CATalog?Comments A series of quoted strings separated with commas is returned: :COPYParameters The arb name may contain up to 8 characters. The first character must be a Comments The following built-in waveform names are reserved and cannot be used with 82 :DELeteParameters The arb name may contain up to 8 characters. The first character must be a Comments You cannot delete the arbitrary waveform that is current ly being output. If you 83 :DEL:ALLComments The colon before the ALL parameter is required. :NVOLatile:CATalog?Comments A series of quoted strings separated with commas is returned (seeexample :NVOLatile:FREE? 84 FORMatSubsystem Syntax :BORDerComments The function generator represents binary data as 12-bit integers, which are sent :BORDer? 85 MEMorySubsystem Syntax :STATe :DE Let eComments Four memory locations, 0, 1, 2 and 3, are available to store configurations.The :STATe :RE Cal l:A UTOcomments When the auto-recall mode is "OFF" (factory default), the function generator 86 Usage Comments Returned Value: 0 or 1 STATe:RECall:AUTO? 87 OUTPut Subsystem Syntax :LOADComments The amplitude (or dc offset) is automatically adjusted if you change the output :LOAD? 90 PHASe Only valid with Option 001 Subsystem Syntax :ADJustComments You must specify "DEG" following the phase value if you spe c i fy the phase in 92 [SOURce:]93 Amplitude Modulation (AM) CommandsAM:DEPThComments If you select the external modulating source (AM:SOUR EXT), the 96 APPLy CommandsNote APPLy Command Parameters 97 99 Comments Four low-level commands are required to program the function generator with 100 APPLy:DCAPPLy:NOISe APPLy:RAMP APPLy:SINusoid 101 APPLy:SQUareComments Square Wave Frequency and Possibl e Conflict with Duty Cycle: APPLy:TRIangle APPLy:USERComments See Arbitrary Waveforms on page46. for more information on creating and APPLy?Comments The function, frequency, amplitude and offset voltage are returned as shown in 102 BURST MODULATION COMMANDSBM:NCYClesBurstCount Comments For sine, square, and arbitrary waveforms (does not apply to ramp an d tria ngle BM:NCYCles?CarrierFrequency -------------------------------- -----------------500 second s 103 BM:PHASeComments For sine, square, triangle, and ramp waveforms, 0 degrees is the point at which BM:PHASe? BM:INTernal:RATEComments The burst rate setting is used only when internal triggering is enabled BM:INTernal:RATE? BM:SOURceComments When the internal burst source is selected, the external gated mode isdisabled. BM:SOURce? BM:STATe BM:STATe? 104 FM COMMANDS105 FM:DEViationComments The carrier frequency must always be greater than or equal to the peak FM:DEViation? FM:INTernal:FREQuency 106 FM:INTernal:FREQuency?FM:INTernal:FUNCtion FM:INTernal:FUNCtion? FM: STATe FM: STATe? FREQuencyComments For arbitrary waveforms that you create and download to memory, 107 FREQuency? FREQuency:STARt FREQuency:STARt? FREQuency:STOP FREQuency:STOP? 108 Frequency-Shift Keying (FSK) Commands109 FSKey:FREQuencyFSKey:FREQuency? FSKey:INTernal:RATEComments The FSK rate is ignored when the external source is selected (FSK:SOUR FSKey:INTernal:RATE? FSKey:SOURceComments When the internal source is selected, the r ate at which the output frequency FSKey:SOURce? FSKey:STATe FSKey:STATe? 110 Selecting an Arbitrary WaveformFUNCtion:USER Comments The names of the five built-in arbitrary waveforms are: 111 FUNCtion:USER? FUNCtion:SHAPeComments Use the FREQ, VOLT, and VOLT:OFFS commands to select the frequency, 112 FUNCtion:SHAPe? PULSe:DCYCleComments Duty cycle: 20% to 80%, in 1% increment s (frequency 5 MHz). 113 PULSe:DCYCle? SWEep:SPACing SWEep:SPACing? SWEep:TIMEComments The number of frequency points in the sweep depends on the sweep time you SWEep:TIME? 114 SWEep:STATeSWEep:STATe? VOLTageComments For arbitrary waveforms, the maximum amplitude will be limited if the data 115 VOLTage? VOLTage:OFFSetComments You can set the offset to a positive or negative number with the restrictions 116 VOLTage:OFFSet? VOLTage:UNIT VOLTage:UNIT? 117 STATusSubsystem Syntax Comments The STATus system contains four registers, two of which are under IEEE :PRESet :QUEStionable :CONDition? :QUEStionable [:EVENt]? 120 SYSTemSubsystem Syntax :ERRor?Comments When an error is generated by the function generator, it stores an error number :VERSion?Comments The information returned is in the format "YYYY.R" where "YYYY" is the 121 TRIGger Subsystem Syntax Parameters BUS: A software trigger; the Group Execute Trigger (GET) bus command or :SLOPe :SLOPe?Comments Returns: "POS" or "NEG" :SOURce 122 Comments When the Immediate (internal) source is selected, the function generator 123 :SOURce? 124 IEEE 488.2Common CommandReference128 *SAVComments Configurations saved to location 0 are recalled when the function generator is *SREComments Coupled command: No Example 130 Agilent E1441A SCPI Command Reference Chapter 3 130 Agilent E1441A Power-On and Reset StateNote auto-recall mode. See MEMory:STA Te:RECall:AUTO OFF | ON | 0 | 1 on page 85. Feature Power-On and Reset State 131 SCPI Command Quick ReferenceAppendix A 135 Agilent E1441A Specifications141 Agilent E1441A Error Messages153 Agilent E1441A Function Generator Tutorial163 Service Procedures
Also you can find more Agilent Technologies manuals or manuals for other Kitchen Appliance.