SWEep:STATe

SWEep:STATe

[SOURce:]SWEep:STATe OFFON disables or enables the sweep mode. To ensure proper operation, you should enable the sweep mode after you have set up the other sweep parameters. Only one modulation mode can be enabled at a time. When you enable the sweep mode, the previous modulation mode is turned off.

SWEep:STATe?

[SOURce:]SWEep:STATe? queries the state of the sweep mode. Returns “0” (OFF) or “1” (ON).

VOLTage

[SOURce:]VOLTage <amplitude>MINMAX sets the output amplitude for the currently active function. MIN selects the smallest amplitude allowed for the selected function (50 mVpp into 50 ohms). MAX selects the largest amplitude allowed (10 Vpp into 50 ohms). The default amplitude is 100 mVpp (into 50 ohms). [ Stored in volatile memory ]

Parameters

Parameter

Parameter

Function

Output

Minimum

Maximum

Default

Name

Type

 

Termination

Amplitude

Amplitude

Units

 

 

 

 

 

 

 

amplitude

numeric

Sine

50

50 mVpp

10 Vpp

Vpp

 

 

 

 

 

 

 

 

 

Square

50

50 mVpp

10 Vpp

 

 

 

 

 

 

 

 

 

 

Triangle

50

50 mVpp

10 Vpp

 

 

 

 

 

 

 

 

 

 

Ramp

50

50 mVpp

10 Vpp

 

 

 

 

 

 

 

 

 

 

Noise

50

50 mVpp

10 Vpp

 

 

 

 

 

 

 

 

 

 

Built-In

50

50 mVpp

10 Vpp

 

 

 

Arbs

 

 

 

 

 

 

 

 

 

 

 

amplitude

numeric

Sine

Open Circuit

100 mVpp

20 Vpp

Vpp

 

 

 

 

 

 

 

 

 

Square

Open Circuit

100 mVpp

20 Vpp

 

 

 

 

 

 

 

 

 

 

Triangle

Open Circuit

100 mVpp

20 Vpp

 

 

 

 

 

 

 

 

 

 

Ramp

Open Circuit

100 mVpp

20 Vpp

 

 

 

 

 

 

 

 

 

 

Noise

Open Circuit

100 mVpp

20 Vpp

 

 

 

 

 

 

 

 

 

 

Built-In

Open Circuit

100 mVpp

20 Vpp

 

 

 

Arbs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments For arbitrary waveforms, the maximum amplitude will be limited if the data points do not span the full range of the output DAC (Digital- to-Analog Converter). For example, the built-inSINC” waveform does not use the full range of values between ±1 and therefore its maximum amplitude is 6.084 Vpp (into 50 ohms).

114 Agilent E1441A SCPI Command Reference

Chapter 3

Page 114
Image 114