Bryant 581A/B manuals
Household Appliance > Heating System
When we buy new device such as Bryant 581A/B we often through away most of the documentation but the warranty.
Very often issues with Bryant 581A/B begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Heating System Bryant 581A/B is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Heating System on our side using links below.
268 pages 6.21 Mb
Form No. PDS 580F.36.3 COMMERCIAL SINGLE PACKAGE ROOFTOP UNITS GAS HEATING/ELECTRIC COOLING UNITS Natural gas LP conversion kits Low NO Optional stainless steel heat exchangers. FEATURES/BENEFITS 580F, 579F, 581A/B DuraPac and DuraPac Plus SeriesSizes 036-3003 to 25 Tons2 TABLE OF CONTENTS5 580F036-150 (Standard and Medium Efficiency) 3 to 121/2 Tons581B036-150 (High Efficiency) 3 to 121/2 Tons580F E V 060 120 N KB 581B E V 060 120 N DA 6 MODEL NUMBER NOMENCLATURE 579F180-300579F E V 180 230 C B 580F E V 180 275 C B 7 581A155, 180, 181 13 to 15 Tons581A210-300 18 to 25 Tons581A E V 180 230 C B 5 8 1 A E A 2 1 0 2 5 0 A A 8 ARI* CAPACITY RATINGS 580F036-151HEATING CAPACITIES AND EFFICIENCIES (Standard-Efficiency Units) 580F036-151 9 ARI* CAPACITY RATINGS (cont)HEATING CAPACITIES AND EFFICIENCIES (Standard Efficiency Units) 580F036-151 (cont) HEATING CAPACITIES AND EFFICIENCIES (Medium-Efficiency Units) 580F036-151 10 ARI* CAPACITY RATINGS 581B036-150HEATING CAPACITIES AND EFFICIENCIES 581B036-150 11 ARI* CAPACITY RATINGS (cont)HEATING CAPACITIES AND EFFICIENCIES 581B036-150(cont) 12 ARI* CAPACITY RATINGS 579F180-300HEATING CAPACITIES AND EFFICIENCIES 579F180-300 AIR QUANTITY LIMITS LOW OUTDOOR TEMPERATURE OPERATING LIMITS (F) 13 ARI* CAPACITY RATINGS 580F180-300HEATING CAPACITIES AND EFFICIENCIES 580F180-300 AIR QUANTITY LIMITS (Cooling) COOLING OPERATION LOW OUTDOOR TEMPERATURE OPERATING LIMITS (F) 14 ARI* CAPACITY RATINGS 581A155,180HEATING CAPACITIES AND EFFICIENCIES 581A155-180 AIR QUANTITY LIMITS (Cooling) LOW OUTDOOR AIR TEMPERATURE COOLING OPERATION LIMITS 15 ARI* CAPACITY RATINGS 581A210-300HEATING CAPACITIES AND EFFICIENCIES 581A210-300VERTICAL SUPPLY NATURAL GAS HORIZONTAL SUPPLY NATURAL GAS VERTICAL SUPPLY PROPANE HORIZONTAL SUPPLY PROPANE 16 OPTIONS AND ACCESSORIES20 PHYSICAL DATA 580F036-07321 PHYSICAL DATA 580F036-073 (cont)22 PHYSICAL DATA 580F090,120,150 UNITS23 PHYSICAL DATA 580F090,120,150 UNITS (cont)24 PHYSICAL DATA 580F091,103,121,151 UNITSASHRAE 90.1 COMPLIANT UNITS 25 PHYSICAL DATA 580F091,103,121,151 UNITS (cont)ASHRAE 90.1 COMPLIANT UNITS (cont) 30 ACCESSORY DIMENSIONS 580F31 ACCESSORY DIMENSIONS 580F (cont)a48-7321 Roof Curb Details 32 SELECTION PROCEDURE (with 580F060 example)36 580F036-15151 580F036-15158 580F036-15179 TYPICAL WIRING SCHEMATICS 580F036-151 (580F090, 460-3-60 Shown)80 TYPICAL WIRING SCHEMATICS 580F036-151 (cont)580F036-151EconoMi$er IV Wiring 580F036-151 Units EconoMi$er2 Wiring 580F036-151 Units 81 TYPICAL WIRING SCHEMATICS 580F (cont)RED YEL BLU GRAa48-7463 NOTE: Use copper conductors only. GRARED 600V 460V Convenience Outlet (Optional) Sizes 580F036-151 Non-Fused Disconnect (Optional) Sizes 580F036-151 83 PHYSICAL DATA 581B036-07284 PHYSICAL DATA 581B036-072 (cont)85 PHYSICAL DATA 581B090-15086 PHYSICAL DATA 581B090-150 (cont)88 BASE UNIT DIMENSIONS 581B090-15091 SELECTION PROCEDURE (With 581B048 Example)136 TYPICAL WIRING SCHEMATICS 581B (cont)EconoMi$er IV Wiring 581B036-150 Units EconoMi$er2 Wiring 581B036-150 Units 137 TYPICAL WIRING SCHEMATICS 581B (cont)RED YEL BLU GRAa48-7463 NOTE: Use copper conductors only. GRARED 600V 460V Convenience Outlet (Optional) Sizes 581B036-150 Non-Fused Disconnect (Optional) Sizes 581B036-150 139 GUIDE SPECIFICATIONS 580F036-151 AND 581B036-150142 580F036-150 AND 581B036-150144 PHYSICAL DATA 579F180-300145 PHYSICAL DATA 579F180-300 (cont)OPERATING AND RIGGING WEIGHTS OPTIONS AND ACCESSORIES (Weight Adders) 146 BASE UNIT DIMENSIONS 579F180,216147 BASE UNIT DIMENSIONS 579F240,300149 ACCESSORY DIMENSIONS 579F180-300 (cont)Horizontal Supply/Return Adapter Installation (579F180-300) 151 SELECTION PROCEDURE (With 579F180 Example)152 PERFORMANCE DATA 579F168 TYPICAL WIRING SCHEMATICS 579F (579F240, 208/230 V Shown) (cont)169 TYPICAL WIRING SCHEMATICS 579F (cont)EconoMi$er IV Wiring 579F180-300 Units EconoMi$er2 Wiring 579F180-300 Units 172 PHYSICAL DATA 580F180-300173 PHYSICAL DATA 580F180-300 (cont)OPERATING AND RIGGING WEIGHTS OPTIONS AND ACCESSORIES (Weight Adders) 179 ACCESSORY DIMENSIONS 580F (cont)Horizontal Supply/Return Adapter Installation (580F180-240) 181 SELECTION PROCEDURE (With 580F240 Example)189 PERFORMANCE DATA (cont)\193 TYPICAL WIRING SCHEMATICS 580Fa48-7461 Typical Wiring Schematic 580F180, 460-3-60 Shown 194 TYPICAL WIRING SCHEMATICS 580F (cont)EconoMi$er IV Wiring 580F180-300 EconoMi$er2 Wiring 580F180-300 197 PHYSICAL DATA 581A155,180198 PHYSICAL DATA 581A210-300 LEGEND TXV Thermostatic Expansion Valve 199 PHYSICAL DATA (cont)EVAPORATOR FAN DATA 581A210-300 VERTICAL SUPPLY/RETURN UNITS EVAPORATOR FAN DATA 581A210-300 HORIZONTAL SUPPLY/RETURN UNITS 200 PHYSICAL DATA (cont) OPERATING AND RIGGING WEIGHTS 581A155,180 OPTIONS AND ACCESSORIES 581A155,180 (Weight Adders) OPTIONS AND ACCESSORIES 581A210-300 (Weight Adders) 201 BASE UNIT DIMENSIONS 581A155,180203 ACCESSORY DIMENSIONS 581A155,180204 ACCESSORY DIMENSIONS (cont)Horizontal Supply/Return Adapter Installation (581A155,180) 207 SELECTION PROCEDURE208 COOLING CAPACITIES STANDARD UNITS213 COOLING CAPACITIES, UNITS WITH HOT GAS REHEAT OPTION218 NOTES: Bhp Brake Horsepower Watts Input Watts to Motor 240 ALTITUDE COMPENSATION* 581A155,180 (Natural Gas Units)ALTITUDE COMPENSATION 581A155,180 ALTITUDE COMPENSATION 581A210-300 (Natural Gas) ALTITUDE COMPENSATION 581A210-300 (LP Gas) EVAPORATOR-FAN MOTOR EFFICIENCY 581A155,180 Fan Performance Using Accessory Power Exhaust (581A155,180) 241 ACCESSORY/FIOP STATIC PRESSURE (in. wg)* 581A155,180INDOOR SOUND DATA (TOTAL UNIT) 581A155,180 EVAPORATOR FAN MOTOR PERFORMANCE 581A155,180 FAN RPM AT MOTOR PULLEY SETTINGS* 581A155,180 242 OUTDOOR SOUND POWER (TOTAL UNIT)FAN RPM AT MOTOR PULLEY SETTINGS* 581A210-300 243 EVAPORATOR FAN MOTOR SPECIFICATIONS 581A210-300ACCESSORY/FIOP STATIC PRESSURE (in. wg) 581A210-300 244 ELECTRICAL DATA 581A155,180245 ELECTRICAL DATA 581A210-300 WITHOUT CONVENIENCE OUTLET246 ELECTRICAL DATA 581A210-300 WITH OPTIONAL CONVENIENCE OUTLET247 TYPICAL WIRING SCHEMATICS 581Aa48-7474 581A155, 460-3-60 Shown 248 TYPICAL WIRING SCHEMATICS 581AEconoMi$er IV Wiring 581A155,180 EconoMi$er2 Wiring 581A155,180 250 GUIDE SPECIFICATIONS 579F/580F180-300 AND 581A155,180 SIZE UNITS255 GUIDE SPECIFICATIONS 581A210-300 UNITS259 CONTROLS263 APPLICATION DATAW1 W2266 ECONOMI$ER IV SENSOR USAGE CHARTENTHALPYBTU PER POUND DRY AIR APPLICATION Economizer Changeover CurvesAPPROXIMATE DRY BULB TEMPERATURE F ( C ) A B C DRELATIVE HUMIDITY (%) HIGH LIMIT CURVE a50-7751ECONOMI$ERIV WITH OUTDOOR AIR DRY BULB SENSOR HH57AC078 and CRENTDIF004A00* CGCDXSEN004A00 and CGCDXASP001A00** 267 INDEX
Also you can find more Bryant manuals or manuals for other Household Appliance.