Bryant 581A/B manual 162

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 162
Image 162

579F180-300

PERFORMANCE DATA — 579F (cont)

FAN PERFORMANCE — 579F180-300 UNITS (cont)

579F216360 and 240360 (18 AND 20 TONS) *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

0.6

 

 

 

0.8

 

 

1.0

 

 

1.2

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

 

Watts

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

5,500

795

2.43

2043

866

2.74

 

2306

934

3.07

2578

998

 

3.40

2856

1059

3.74

3142

1117

4.08

3434

6,000

854

2.92

2452

921

3.24

 

2722

984

3.57

3998

1044

 

3.90

3281

1102

4.25

3570

1158

4.60

3865

6,500

914

3.46

2909

977

3.79

 

3184

1036

4.12

3465

1093

 

4.46

3752

1148

4.81

4045

1201

5.16

4343

7,000

975

4.06

3414

1034

4.39

 

3695

1090

4.73

3981

1144

 

5.08

4272

1196

5.43

4569

1246

5.79

4870

7,500

1037

4.72

3969

1092

5.06

 

4255

1145

5.41

4546

1196

 

5.76

4842

1256

6.12

5142

1294

6.48

5447

8,000

1099

5.44

4575

1150

5.79

 

4866

1201

6.14

5162

1249

 

6.50

5462

1297

6.86

5766

1343

7.22

6075

8,500

1161

6.22

5232

1210

6.57

 

5529

1258

6.93

5829

1304

 

7.29

6134

1349

7.66

6443

1393

8.03

6755

9,000

1223

7.07

5943

1270

7.43

 

6245

1315

7.79

6550

1360

 

8.16

6869

1403

8.53

7171

1445

8.90

7487

9,500

1286

7.98

6708

1331

8.34

 

7014

1374

8.71

7324

1416

 

9.08

7638

1457

9.46

7954

1498

9.84

8274

10,000

1349

8.95

7528

1392

9.32

 

7839

1433

9.70

8154

1473

 

10.07

8471

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F216360 and 240360 (18 AND 20 TONS) * (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

1.4

 

 

1.6

 

 

 

1.8

 

 

 

1.9

 

 

2.0

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

 

Watts

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

5,500

1173

4.44

3732

1227

4.80

 

4036

1279

5.17

4345

1304

 

5.35

4502

1329

5.54

4629

 

 

 

6,000

1211

4.95

4165

1263

5.32

 

4471

1313

5.69

4782

1337

 

5.87

4939

1361

6.06

5097

 

 

 

6,500

1252

5.53

4646

1302

5.89

 

4954

1350

6.26

5267

1373

 

6.56

5425

1396

6.64

5584

 

 

 

7,000

1295

6.16

5176

1343

6.52

 

5487

1389

6.90

5802

1412

 

7.09

5961

1434

7.28

6121

 

 

 

7,500

1340

6.85

5756

1386

7.22

 

6070

1431

7.60

6387

1452

 

7.79

6547

1474

7.98

6709

 

 

 

8,000

1388

7.60

6388

1431

7.97

 

6704

1474

8.35

7240

1495

 

8.54

7186

1516

8.74

7348

 

 

 

8,500

1436

8.41

7071

1478

8.79

 

7390

1520

9.17

7713

1540

 

9.37

7876

 

 

 

9,000

1486

9.28

7807

1527

9.67

 

8130

 

 

 

 

9,500

1538

10.22

8597

 

 

 

 

 

10,000

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

Refer to this page for general Fan Performance Data notes.

 

 

Bhp

Brake Horsepower

 

 

 

 

 

 

 

 

NOTE: Maximum continuous bhp for the 216 size is 5.90. Maximum continuous

Watts

Input Watts to Motor

 

 

 

 

 

 

 

 

bhp for the 240 size is 8.70 (208/230 and 575 v) or 9.50 (460 v). The maximum

*Standard low-medium static drive range for the 216 size is 910 to 1095 rpm.

continuous watts for the 216 size is 5180. The maximum continuous watts for the

240 size is 7915 (208/230 and 575 v) or 8640 (460 v). Do not adjust motor rpm

Standard low-medium static drive range for the 240 size is 1002 to 1225 rpm.

such that motor maximum bhp and/or watts is exceeded at the maximum operat-

Alternate high-static drive range for the 216 size is 1069 to 1287. Alternate high-

ing cfm.

 

 

 

 

 

 

 

 

static drive range for the 240 size is 1193 to 1458 rpm. Other rpms require a

 

 

 

 

 

 

 

 

 

 

field-supplied drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F300360 (25 TONS) *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

(Cfm)

 

 

 

0.2

 

 

 

0.4

 

 

 

0.6

 

 

0.8

 

 

1.0

 

 

1.2

 

 

 

 

Rpm

 

Bhp

 

Watts

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

7,000

 

992

 

4.05

 

3,348

1051

4.44

3,668

1106

 

4.83

3995

1160

5.24

4331

1212

5.65

4675

1262

6.08

5026

 

7,500

 

1055

 

4.77

 

3,947

1110

5.17

4,277

1162

 

5.58

4615

1214

6.00

4960

1263

6.43

5312

1311

6.86

5672

 

8,000

 

1118

 

5.58

 

4,610

1170

5.99

4,950

1220

 

6.41

5298

1268

6.84

5653

1315

7.27

6014

1361

7.72

6382

 

8,500

 

1182

 

6.46

 

5,339

1231

6.88

5,690

1278

 

7.31

6047

1324

7.75

6411

1369

8.20

6782

1413

8.66

7158

 

9,000

 

1246

 

7.42

 

6,136

1292

7.86

6,498

1337

 

8.30

6865

1381

8.75

7239

1424

9.21

7618

1466

9.68

8003

 

9,500

 

1310

 

8.47

 

7,005

1354

8.92

7,377

1397

 

9.38

7754

1439

9.84

8137

1480

10.31

8525

1520

10.79

8918

10,000

 

1374

 

9.61

 

7,947

1416

10.07

8,329

1457

 

10.54

8715

1497

11.02

9107

1537

11.50

9504

10,500

 

1439

 

10.84

 

8,964

1479

11.32

9,356

1518

 

11.79

9752

11,000

 

1503

 

12.17

 

10,059

1542

12.65

10,460

 

11,250

 

1536

 

12.86

 

10,636

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F300360 (25 TONS) * (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

(Cfm)

 

 

 

1.4

 

 

 

1.6

 

 

 

1.8

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Watts

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

 

 

 

 

 

 

 

 

 

 

7,000

 

1311

 

6.51

 

5385

1359

6.96

5751

1405

 

6.00

6124

 

 

 

 

 

 

 

 

 

 

7,500

 

1358

 

7.30

 

6039

1403

7.76

6412

1448

 

6.84

6792

 

 

 

 

 

 

 

 

 

 

8,000

 

1406

 

8.17

 

6767

1560

8.63

7137

1492

 

7.75

7524

 

 

 

 

 

 

 

 

 

 

8,500

 

1456

 

9.12

 

7541

1498

9.59

7929

1539

 

8.75

8323

 

 

 

 

 

 

 

 

 

 

9,000

 

1507

 

10.15

 

8393

1548

10.63

8790

 

 

 

 

 

 

 

 

 

 

 

9,500

 

 

 

 

 

 

 

 

 

 

 

 

 

10,000

 

 

 

 

 

 

 

 

 

 

 

 

 

10,500

 

 

 

 

 

 

 

 

 

 

 

 

 

11,000

 

 

 

 

 

 

 

 

 

 

 

 

 

11,250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

Refer to this page for general Fan Performance Data notes.

 

 

Bhp

Brake Horsepower

 

 

 

 

 

 

 

 

NOTE: Maximum continuous bhp is 10.20 (208/230 and 575 v) or 11.80 (460 v)

Watts

Input Watts to Motor

 

 

 

 

 

 

 

 

and the maximum continuous watts are 9510 (208/230 and 575 v) or 11,000

*Standard low-medium static drive range is 1066 to 1283 rpm. Alternate high-

(460 v). Do not adjust motor rpm such that motor maximum bhp and/or watts is

exceeded at the maximum operating cfm.

 

 

 

 

static drive range is 1332 to 1550. Other rpms require a field-supplied drive.

 

 

 

 

 

 

 

 

 

 

 

GENERAL NOTES FOR FAN PERFORMANCE DATA TABLES

1.Static pressure losses (i.e., EconoMi$er IV) must be added to external static pressure before entering Fan Performance table.

2.Interpolation is permissible. Do not extrapolate.

3.Fan performance is based on wet coils, clean filters, and casing losses. See Accessory/FIOP Static Pressure table on page 164.

4.Extensive motor and drive testing on these units ensures that the full horse- power and watts range of the motor can be utilized with confidence. Using fan motors up to the watts or bhp rating shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.

5.Use of a field-supplied motor may affect wire sizing. Contact your Bryant representative for details.

162

Page 162
Image 162
Bryant 581A/B manual 162

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.