Bryant 581A/B manual 581B102 81/2 Tons Standard Motor Belt Drive

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 110
Image 110

PERFORMANCE DATA (cont)

FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)

 

 

 

581B102 (81/2 TONS) — STANDARD MOTOR (BELT DRIVE)*

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

0.6

 

 

0.8

 

 

1.0

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

2500

541

0.50

467

624

0.66

614

 

701

0.83

771

771

1.00

936

837

1.19

1109

 

 

 

2600

556

0.55

513

637

0.71

665

 

711

0.89

827

781

1.07

996

845

1.26

1173

 

 

 

2700

571

0.60

562

650

0.77

720

 

722

0.95

885

790

1.14

1059

854

1.33

1241

 

 

 

2800

586

0.66

615

663

0.83

777

 

734

1.02

948

800

1.21

1126

863

1.41

1312

 

 

 

2900

601

0.72

672

676

0.90

839

 

745

1.09

1014

811

1.28

1197

872

1.49

1387

 

 

 

3000

616

0.79

732

689

0.97

904

 

757

1.16

1083

821

1.36

1271

882

1.57

1465

 

 

 

3100

632

0.85

796

703

1.04

972

 

769

1.24

1157

832

1.45

1349

892

1.66

1548

 

 

 

3200

648

0.93

864

717

1.12

1045

 

782

1.32

1235

843

1.53

1431

902

1.75

1635

 

 

 

3300

663

1.00

936

731

1.20

1122

 

795

1.41

1316

855

1.63

1517

912

1.85

1725

 

 

 

 

 

 

 

3400

679

1.09

1012

745

1.29

1203

 

808

1.50

1402

867

1.72

1608

923

1.95

1820

 

150

 

3500

695

1.17

1092

760

1.38

1288

 

821

1.60

1492

879

1.83

1703

934

2.06

1920

 

 

3600

711

1.26

1177

774

1.48

1379

 

834

1.70

1587

891

1.93

1802

945

2.17

2024

 

581B036-

 

3700

728

1.36

1266

789

1.58

1473

 

848

1.81

1686

904

2.04

1906

957

2.29

2132

 

 

3800

744

1.46

1361

804

1.69

1572

 

861

1.92

1790

916

2.16

2015

969

2.41

2246

 

 

3900

760

1.57

1460

819

1.80

1676

 

875

2.04

1899

929

2.28

2128

981

2.53

2364

 

 

 

4000

777

1.68

1563

834

1.91

1785

 

889

2.16

2012

942

2.41

2247

993

2.67

2487

 

 

 

4100

793

1.79

1672

850

2.04

1899

 

904

2.29

2132

956

2.54

2371

1006

2.80

2615

 

 

 

4200

810

1.92

1786

865

2.16

2018

 

918

2.42

2255

969

2.68

2499

 

 

 

4300

826

2.04

1906

880

2.30

2142

 

932

2.56

2385

983

2.82

2633

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581B102 (81/2 TONS) — STANDARD MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

1.2

 

 

1.4

 

 

 

1.6

 

 

1.8

 

 

2.0

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

2500

900

1.38

1289

959

1.58

1476

 

1015

1.79

1669

1069

2.00

1868

1121

2.22

2073

 

 

 

2600

907

1.46

1357

965

1.66

1548

 

1021

1.87

1745

1074

2.09

1948

1125

2.31

2158

 

 

 

2700

914

1.53

1429

972

1.74

1624

 

1027

1.96

1825

1079

2.18

2032

1130

2.41

2245

 

 

 

2800

922

1.61

1505

979

1.83

1704

 

1033

2.05

1909

1085

2.27

2120

1135

2.51

2337

 

 

 

2900

931

1.70

1584

986

1.92

1787

 

1040

2.14

1996

1091

2.37

2211

1141

2.61

2432

 

 

 

3000

939

1.79

1667

994

2.01

1874

 

1047

2.24

2087

1098

2.47

2307

1147

2.71

2532

 

 

 

3100

948

1.88

1753

1002

2.11

1965

 

1054

2.34

2183

1105

2.58

2406

1153

2.83

2635

 

 

 

3200

957

1.98

1844

1011

2.21

2060

 

1062

2.45

2283

1112

2.69

2510

 

 

 

3300

967

2.08

1939

1020

2.32

2160

 

1070

2.56

2386

1119

2.81

2618

 

 

 

3400

977

2.19

2039

1029

2.43

2264

 

1079

2.67

2494

 

 

 

3500

987

2.30

2143

1038

2.54

2372

 

1088

2.80

2607

 

 

 

3600

998

2.41

2251

1048

2.66

2485

 

 

 

 

3700

1008

2.54

2364

1058

2.79

2602

 

 

 

 

3800

1019

2.66

2482

 

 

 

 

3900

1031

2.79

2605

 

 

 

 

4000

 

 

 

 

4100

 

 

 

 

4200

 

 

 

 

4300

 

LEGEND

Bhp — Brake Horsepower Input to Fan

Watts — Input Watts to Motor

*Motor drive range: 840 to 1085 rpm. All other rpms require field- supplied drive.

Refer to page 103 for general Fan Performance Data notes.

NOTES:

1.Boldface indicates field-supplied drive is required.

2.Maximum continuous bhp is 2.90.

110

Page 110
Image 110
Bryant 581A/B manual 581B102 81/2 Tons Standard Motor Belt Drive

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.