Bryant 581A/B manual FAN Performance 579F180-300 Units

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 160
Image 160

579F180-300

PERFORMANCE DATA — 579F (cont)

FAN PERFORMANCE — 579F180-300 UNITS

579F180230 (15 TONS) *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

 

0.6

 

 

 

0.8

 

 

1.0

 

 

1.2

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

 

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

4500

809

 

1.53

1317

906

1.74

 

1502

 

994

1.96

1690

1078

 

2.18

1882

1156

2.41

2077

1230

2.64

2275

 

4800

850

 

1.76

1516

942

1.98

 

1706

 

1027

2.20

1899

1107

 

2.43

2094

1183

2.66

2293

1255

2.89

2495

 

5100

892

 

2.01

1733

979

2.24

 

1928

 

1061

2.46

2125

1138

 

2.70

2325

1211

2.93

2528

1281

3.17

2733

 

5400

934

 

2.28

1970

1017

2.52

 

2169

 

1096

2.75

2371

1170

 

2.99

2575

1241

3.22

2781

1309

3.47

2990

 

5700

976

 

2.58

2225

1056

2.82

 

2429

 

1132

3.06

2635

1204

 

3.30

2843

1272

3.54

3053

1338

3.79

3266

 

6000

1019

 

2.90

2500

1096

3.14

 

2709

 

1168

3.38

2919

1238

 

3.63

3131

1304

3.88

3345

1368

4.13

3562

 

6300

1063

 

3.24

2795

1136

3.49

 

3008

 

1206

3.74

3223

1273

 

3.99

3439

1337

4.24

3657

 

6600

1106

 

3.61

3111

1177

3.86

 

3329

 

1244

4.11

3547

1309

 

4.37

3767

 

6900

1150

 

4.00

3448

1218

4.26

 

3670

 

 

 

7200

 

 

 

 

 

7500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F180230 (15 TONS)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

1.4

 

 

1.6

 

 

 

 

1.8

 

 

 

1.9

 

 

2.0

 

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

 

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

 

4500

1301

 

2.87

2477

1369

3.11

 

2683

 

1434

3.35

2891

1497

 

3.47

2997

1497

3.60

3103

 

 

 

 

4800

1324

 

3.13

2700

1390

3.37

 

2909

 

1454

3.62

3120

1515

 

3.74

3226

1515

3.87

3334

 

 

 

 

5100

1349

 

3.41

2942

1413

3.66

 

3153

 

1475

3.90

3367

1535

 

4.03

3475

1535

4.16

3584

 

 

 

 

5400

1374

 

3.71

3202

1437

3.96

 

3416

 

1498

4.21

3633

 

 

 

 

 

5700

1402

 

4.04

3481

1463

4.29

 

3699

 

 

 

 

 

 

6000

 

 

 

 

 

 

 

 

6300

 

 

 

 

 

 

 

 

6600

 

 

 

 

 

 

 

 

6900

 

 

 

 

 

 

 

 

7200

 

 

 

 

 

 

 

 

7500

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

Refer to page 162 for general Fan Performance Data notes.

 

 

Bhp

Brake Horsepower

 

 

 

 

 

 

 

 

NOTE: Maximum continuous bhp is 4.25 (208/230 v and 460 v) or 3.45 (575 v)

Watts — Input Watts to Motor

 

 

 

 

 

 

 

 

and the maximum continuous watts are 3775 (208/230 v and 460 v) or 3065

*Standard low-medium static drive range is 891 to 1179 rpm (208/230 v and

(575 v). Do not adjust motor rpm such that motor maximum bhp and/or watts is

exceeded at the maximum operating cfm.

 

 

 

 

460 v) or 1159 to 1429 (575 v). Alternate high-static drive range is 1227 to 1550

 

 

 

 

 

 

 

 

 

 

 

(208/230 v and 460 v only). Other rpms require a field-supplied drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F216275 AND 240275 (18 AND 20 TONS) *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

 

0.6

 

 

 

0.8

 

 

1.0

 

 

1.2

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

 

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

5,500

755

 

2.27

1908

831

2.58

 

2171

 

901

2.91

2443

968

 

3.24

2723

1031

3.58

3009

1091

3.93

3302

 

6,000

810

 

2.72

2287

881

3.04

 

2556

 

947

3.37

2833

1010

 

3.71

3116

1070

4.05

3406

1127

4.40

3702

 

6,500

866

 

3.22

2710

932

3.55

 

2985

 

994

3.88

3266

1054

 

4.23

3554

1111

4.57

3847

1166

4.93

4146

 

7,000

923

 

3.78

3177

985

4.11

 

3458

 

1044

4.45

3744

1100

 

4.80

4036

1155

5.15

4333

1207

5.51

4635

 

7,500

980

 

4.39

3690

1038

4.73

 

3976

 

1094

5.07

4267

1148

 

5.43

4564

1200

5.78

4864

1250

6.15

5170

 

8,000

1038

 

5.06

4251

1093

5.40

 

4542

 

1146

5.75

4838

1197

 

6.11

5138

1246

6.47

5443

1294

6.84

5752

 

8,500

1096

 

5.78

4859

1148

6.13

 

5156

 

1198

6.49

5456

1247

 

6.85

5761

1294

7.22

6070

1340

7.59

6382

 

9,000

1154

 

6.56

5517

1204

6.92

 

5818

 

1251

7.28

6123

1298

 

7.65

6432

1343

8.02

6745

1388

8.40

7062

 

9,500

1213

 

7.40

6224

1260

7.77

 

6531

 

1306

8.13

6840

1350

 

8.51

7154

1394

8.88

7471

1436

9.26

7791

 

10,000

1272

 

8.30

6983

1317

8.67

 

7294

 

1360

9.05

7608

1403

 

9.43

7926

1445

9.81

8247

1486

10.19

8570

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F216275 AND 240275 (18 AND 20 TONS)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

1.4

 

 

1.6

 

 

 

 

1.8

 

 

 

1.9

 

 

2.0

 

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

 

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

 

5,500

1149

 

4.28

3602

1204

4.65

 

3907

 

1258

5.02

4217

1284

 

5.20

4375

1309

5.39

4533

 

 

 

 

6,000

1183

 

4.76

4003

1236

5.13

 

4310

 

1288

5.50

4622

1313

 

5.68

4780

1337

5.87

4939

 

 

 

 

6,500

1219

 

5.29

4450

1270

5.66

 

4759

 

1320

6.03

5073

1344

 

6.22

5232

1368

6.41

5391

 

 

 

 

7,000

1258

 

5.88

4942

1307

6.25

 

5253

 

1355

6.62

5569

1378

 

6.81

5729

1402

7.00

5890

 

 

 

 

7,500

1299

 

6.52

5480

1346

6.89

 

5794

 

1392

7.27

6113

1415

 

7.46

6273

1437

7.65

6435

 

 

 

 

8,000

1341

 

7.21

6065

1387

7.59

 

6383

 

1392

7.97

6704

1453

 

8.16

6866

1475

8.36

7300

 

 

 

 

8,500

1385

 

7.97

6699

1429

8.35

 

7019

 

1472

8.73

7343

1493

 

8.93

7506

1514

9.12

7670

 

 

 

 

9,000

1431

 

8.78

7382

1473

9.15

 

7705

 

1515

9.55

8032

1535

 

9.75

8196

 

 

 

 

9,500

1478

 

9.65

8114

1519

10.04

 

8441

 

 

 

 

 

 

10,000

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

Refer to page 162 for general Fan Performance Data notes.

 

 

Bhp

Brake Horsepower

 

 

 

 

 

 

 

 

NOTE: Maximum continuous bhp for the 216 size is 5.90. Maximum continuous

Watts — Input Watts to Motor

 

 

 

 

 

 

 

 

bhp for the 240 size is 8.70 (208/230 and 575 v) or 9.50 (460 v). The maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

continuous watts for the 216 size is 5180. The maximum continuous watts for the

*Standard low-medium static drive range for the 216 size is 910 to 1095 rpm.

240 size is 7915 (208/230 and 575 v) or 8640 (460 v). Do not adjust motor rpm

Standard low-medium static drive range for the 240 size is 1002 to 1225 rpm.

such that motor maximum bhp and/or watts is exceeded at the maximum operat-

Alternate high-static drive range for the 216 size is 1069 to 1287. Alternate high-

ing cfm.

static drive range for the 240 size is 1193 to 1458 rpm. Other rpms require a field-

 

supplied drive.

 

160

Page 160
Image 160
Bryant 581A/B manual FAN Performance 579F180-300 Units

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.