PERFORMANCE DATA (cont)

FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)

581A240 (20 TONS) (Low Heat Units)*

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

0.2

 

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

 

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

5,000

590

1276

1.47

 

663

1516

1.74

727

1745

2.01

786

1968

2.26

840

2189

2.52

5,500

633

1579

1.82

 

703

1838

2.11

764

2084

2.40

820

2324

2.67

872

2560

2.94

6,000

677

1925

2.21

 

744

2203

2.53

803

2467

2.84

857

2723

3.13

907

2974

3.42

6,500

722

2317

2.67

 

786

2614

3.01

842

2896

3.33

894

3167

3.64

942

3434

3.95

7,000

767

2758

3.17

 

828

3073

3.53

883

3371

3.88

933

3660

4.21

979

3942

4.53

7,500

813

3250

3.74

 

871

3582

4.12

924

3897

4.48

972

4202

4.83

1017

4500

5.18

8,000

859

3795

4.36

 

915

4143

4.77

966

4475

5.15

1012

4797

5.52

1056

5110

5.88

8,500

906

4394

5.05

 

959

4759

5.47

1008

5107

5.87

1053

5445

6.26

1096

5774

6.64

9,000

952

5051

5.81

 

1004

5432

6.25

1051

5797

6.67

1095

6150

7.07

1136

6494

7.47

9,500

999

5767

6.63

 

1049

6163

7.09

1094

6544

7.53

1137

6913

7.95

1177

7272

8.36

10,000

1047

6544

7.53

 

1094

6956

8.00

1138

7352

8.46

1180

7736

8.90

1219

8111

9.33

 

 

 

 

 

 

 

 

 

 

 

 

581A240 (20 TONS) (Low Heat Units)* (cont)

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

1.2

 

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

 

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

5,000

891

2408

2.77

 

940

2625

3.02

987

2843

3.27

1032

3060

3.52

1076

3277

3.77

5,500

921

2792

3.21

 

968

3024

3.48

1014

3255

3.74

1057

3485

4.01

1099

3716

4.27

6,000

954

3221

3.70

 

999

3467

3.99

1042

3711

4.27

1084

3955

4.55

1125

4198

4.83

6,500

988

3696

4.25

 

1032

3956

4.55

1073

4214

4.85

1114

4470

5.14

1153

4726

5.44

7,000

1024

4219

4.85

 

1066

4493

5.17

1106

4764

5.48

1145

5034

5.79

1183

5303

6.10

7,500

1060

4792

5.51

 

1101

5080

5.84

1140

5365

6.17

1178

5649

6.50

1215

5930

6.82

8,000

1098

5417

6.23

 

1138

5719

6.58

1176

6018

6.92

1213

6315

7.26

1249

6610

7.60

8,500

1137

6096

7.01

 

1175

6413

7.38

1212

6726

7.74

1248

7036

8.09

1283

7344

8.45

9,000

1176

6831

7.86

 

1214

7163

8.24

1250

7490

8.61

1285

7814

8.99

1319

8135

9.36

9,500

1216

7624

8.77

 

1253

7970

9.17

1288

8312

9.56

1322

8649

9.95

1355

8984

10.33

10,000

1256

8478

9.75

 

1292

8838

10.16

1327

9193

10.57

1360

9545

10.98

1393

9893

11.38

 

 

LEGEND

Refer to page 230 for general Fan Performance Data notes.

Bhp

Brake Horsepower Input to Fan

NOTE: Maximum continuous bhp is:

Watts

Input Watts to Motor

Low Range: 5.75

High Range: 8.63

*Motor drive ranges:

Low Range: 949-1206

High Range: 941-1176

All other rpms require field-supplied drive.

581A155-300

225

Page 225
Image 225
Bryant 581A/B manual Rpm Watts Bhp 000, 500

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.