Bryant 581A/B manual 1074, 1497, 2700 1280 1660, Cfm Rpm Bhp Watts 1800

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 119
Image 119

PERFORMANCE DATA (cont)

FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS (cont)

581B072 (6 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)*

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

1800

913

0.64

569

1010

0.80

715

1098

0.98

869

1178

1.16

1032

1252

1.35

1203

 

 

 

1900

952

0.73

652

1046

0.91

805

1131

1.09

965

1210

1.28

1134

1282

1.48

1311

 

 

 

2000

992

0.84

744

1083

1.02

903

1166

1.21

1070

1242

1.40

1245

1313

1.61

1427

 

 

 

2100

1032

0.95

844

1120

1.14

1010

1200

1.33

1184

1275

1.54

1365

1345

1.75

1553

 

 

 

2200

1073

1.07

954

1158

1.27

1127

1236

1.47

1307

1308

1.68

1495

1377

1.90

1689

 

 

 

2300

1114

1.21

1074

1196

1.41

1254

1272

1.62

1440

1343

1.84

1634

1409

2.07

1834

 

 

 

2400

1155

1.36

1204

1234

1.57

1391

1308

1.78

1584

1377

2.01

1784

1443

2.24

1990

 

 

 

2500

1196

1.51

1345

1273

1.73

1538

1345

1.96

1738

1412

2.19

1945

1477

2.43

2157

 

 

 

2600

1238

1.69

1497

1312

1.91

1697

1382

2.14

1904

1448

2.38

2117

1511

2.63

2335

 

 

 

2700

1280

1.87

1660

1352

2.10

1867

1420

2.34

2081

1484

2.59

2300

1546

2.84

2526

 

 

 

2800

1322

2.07

1835

1392

2.31

2050

1458

2.56

2270

1521

2.81

2496

 

 

 

2900

1364

2.28

2023

1432

2.53

2245

1496

2.78

2472

 

581B036

 

3000

1406

2.50

2224

1472

2.76

2452

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581B072 (6 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

 

-150

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

1800

1322

1.56

1382

1388

1.77

1568

1451

1.98

1762

1510

2.21

1962

1568

2.44

2169

 

 

 

1900

1351

1.68

1495

1416

1.90

1686

1477

2.12

1885

1536

2.35

2090

1593

2.59

2302

 

 

 

2000

1380

1.82

1617

1444

2.04

1814

1505

2.27

2017

1563

2.51

2227

1619

2.75

2443

 

 

 

2100

1411

1.97

1748

1473

2.20

1950

1533

2.43

2159

1590

2.67

2374

 

 

 

2200

1441

2.13

1890

1503

2.36

2097

1562

2.60

2311

1618

2.85

2532

 

 

 

2300

1473

2.30

2041

1533

2.54

2254

1591

2.79

2474

 

 

 

2400

1505

2.48

2203

1564

2.73

2422

 

 

 

2500

1537

2.68

2376

 

 

 

2600

1571

2.88

2560

 

 

 

2700

 

 

 

2800

 

 

 

2900

 

 

 

3000

 

 

 

LEGEND

Bhp — Brake Horsepower

Watts — Input Watts to Motor

*Motor drive range: 1300 to 1686 rpm. All other rpms require field- supplied drive.

See page 103 for general fan performance notes.

NOTES:

1.Boldface indicates field-supplied drive is required.

2.Maximum continuous bhp is 2.90.

119

Page 119
Image 119
Bryant 581A/B manual 1074, 1497, 2700 1280 1660, Cfm Rpm Bhp Watts 1800, 581B072 6 Tons HIGH-STATIC Motor Belt Drive

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.