Bryant 581A/B manual 581A240 20 Tons Medium Heat Units

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 226
Image 226

PERFORMANCE DATA (cont)

FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)

581A240 (20 TONS) (Medium Heat Units)*

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

5,000

607

1329

1.53

677

1565

1.80

740

1791

2.06

797

2013

2.31

850

2231

2.57

5,500

652

1648

1.90

719

1902

2.19

779

2145

2.47

833

2382

2.74

884

2616

3.01

6,000

699

2013

2.32

763

2285

2.63

819

2545

2.93

872

2798

3.22

921

3046

3.50

6,500

746

2428

2.79

807

2716

3.12

861

2993

3.44

911

3262

3.75

958

3525

4.05

7,000

794

2895

3.33

851

3198

3.68

904

3491

4.02

952

3776

4.34

998

4055

4.66

7,500

842

3415

3.93

897

3735

4.30

947

4043

4.65

994

4343

5.00

1038

4637

5.33

8,000

891

3992

4.59

943

4327

4.98

991

4650

5.35

1036

4966

5.71

1079

5274

6.07

8,500

940

4628

5.32

990

4977

5.72

1036

5316

6.11

1080

5646

6.49

1121

5970

6.87

9,000

990

5325

6.12

1037

5688

6.54

1082

6042

6.95

1124

6386

7.35

1163

6724

7.73

9,500

1039

6085

7.00

1085

6462

7.43

1128

6829

7.85

1168

7188

8.27

1207

7541

8.67

10,000

1089

6911

7.95

1133

7301

8.40

1174

7682

8.83

1213

8055

9.26

1251

8421

9.69

 

 

 

 

 

 

 

 

 

 

 

581A240 (20 TONS) (Medium Heat Units)* (cont)

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

5,000

900

2448

2.82

949

2664

3.06

995

2879

3.31

1040

3095

3.56

1083

3310

3.81

5,500

933

2847

3.27

979

3077

3.54

1023

3305

3.80

1066

3534

4.06

1108

3762

4.33

6,000

967

3292

3.79

1011

3535

4.07

1054

3778

4.35

1095

4019

4.62

1135

4260

4.90

6,500

1003

3785

4.35

1046

4043

4.65

1087

4298

4.94

1127

4553

5.24

1165

4806

5.53

7,000

1041

4330

4.98

1082

4601

5.29

1122

4870

5.60

1160

5138

5.91

1197

5404

6.22

7,500

1079

4926

5.67

1119

5212

5.99

1158

5495

6.32

1195

5776

6.64

1231

6055

6.96

8,000

1119

5578

6.42

1158

5878

6.76

1195

6174

7.10

1231

6468

7.44

1267

6761

7.78

8,500

1160

6288

7.23

1198

6601

7.59

1234

6912

7.95

1269

7219

8.30

1303

7524

8.65

9,000

1202

7056

8.12

1238

7384

8.49

1273

7708

8.87

1308

8029

9.23

1341

8347

9.60

9,500

1244

7887

9.07

1279

8228

9.46

1314

8566

9.85

1347

8900

10.24

1379

9231

10.62

10,000

1287

8781

10.10

1321

9137

10.51

1355

9488

10.91

1387

9836

11.31

 

 

LEGEND

Refer to page 230 for general Fan Performance Data notes.

Bhp

Brake Horsepower Input to Fan

NOTE: Maximum continuous bhp is:

Watts

Input Watts to Motor

Low Range: 5.75

High Range: 8.63

*Motor drive ranges:

Low Range: 949-1206

High Range: 941-1176

All other rpms require field-supplied drive.

581A155-300

226

Page 226
Image 226
Bryant 581A/B manual 581A240 20 Tons Medium Heat Units

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.