Bryant 581A/B ARI* Capacity Ratings 581A210-300, Heating Capacities and Efficiencies 581A210-300

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 15
Image 15

ARI* CAPACITY RATINGS — 581A210-300

UNIT

NOMINAL

CFM

NET COOLING

TOTAL

EER

SOUND RATING

IPLV†

581A

TONS

CAPACITY (Btuh)

kW

(dB)

 

 

 

210

18

5,500

200,000

18.5

10.8

81.7

12.0

240

20

6,000

234,000

21.7

10.8

81.7

11.9

300**

25

7,500

278,000

27.8

10.0

84.6

10.9

 

 

LEGEND

db

Dry Bulb

EER —

Energy Efficiency Ratio

IPLV

Integrated Part-Load Values

wb

Wet Bulb

*Air Conditioning and Refrigeration Institute.

†IPLV values are calculated based on control configuration T.CTL = 2 (2 Stage Y1).

**Size 300 unit is not listed with ARI, but is tested to ARI standards.

NOTES:

1.Rated in accordance with ARI Standards 360-93 and 270-95.

2.ARI ratings are net values, reflecting the effects of circulating fan heat.

3.Ratings are based on:

Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature and 95 F db air entering outdoor unit.

IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F db outdoor entering-air temperature.

4.All 581A210-300 units are in compliance with ASHRAE 90.1 2001 Energy Standard for minimum EER requirements. Refer to state and local codes or visit the following website: http://solstice.crest.org/efficiency/bcap to deter- mine if compliance with this standard pertains to a given geographical area of the United States.

HEATING CAPACITIES AND EFFICIENCIES — 581A210-300

VERTICAL SUPPLY — NATURAL GAS

UNIT

HEATING INPUT

OUTPUT CAPACITY

TEMPERATURE

STEADY-STATE

MINIMUM

581A

(Btuh) Stage 2/Stage 1

(Btuh)

RISE (F)

EFFICIENCY %

HEATING CFM

210250

250,000/199,000

205,000

15-45

82%

4218

210365

365,000/281,000

296,000

25-55

81%

4977

210400

400,000/317,000

328,000

25-55

82%

5522

240250

250,000/199,000

205,000

15-45

82%

4218

240365

365,000/281,000

296,000

25-55

81%

4977

240400

400,000/317,000

328,000

25-55

82%

5522

300250

250,000/199,000

205,000

15-45

82%

4218

300365

365,000/281,000

296,000

25-55

81%

4977

300400

400,000/317,000

328,000

25-55

82%

5522

NOTE: All units are 2-stage gas heat.

HORIZONTAL SUPPLY — NATURAL GAS

UNIT

HEATING INPUT

OUTPUT CAPACITY

TEMPERATURE

STEADY-STATE

MINIMUM

581A

(Btuh) Stage 2/Stage 1

(Btuh)

RISE (F)

EFFICIENCY %

HEATING CFM

210250

250,000/199,000

205,000

15-45

82%

4218

210365

365,000/281,000

296,000

25-55

81%

4977

210400

400,000/317,000

328,000

25-55

82%

5522

240250

250,000/199,000

205,000

15-45

82%

4218

240365

365,000/281,000

296,000

25-55

81%

4977

240400

400,000/317,000

328,000

25-55

82%

5522

300250

250,000/199,000

205,000

15-45

82%

4218

300365

365,000/281,000

296,000

25-55

81%

4977*

300400

400,000/317,000

325,000

25-55

82%

5522*

*7000 cfm minimum recommended above 1.0 in. wg external static pressure.

NOTE: All units are 2-stage gas heat.

VERTICAL SUPPLY — PROPANE

UNIT

HEATING INPUT

OUTPUT CAPACITY

TEMPERATURE

STEADY-STATE

MINIMUM

581A

(Btuh) Stage 2/Stage 1

(Btuh)

RISE (F)

EFFICIENCY %

HEATING CFM

210250

250,000/207,000

205,000

15-45

82%

4218

210365

365,000/291,000

296,000

25-55

81%

4480

210400

400,000/331,000

328,000

25-55

82%

5522

240250

250,000/207,000

205,000

15-45

82%

4218

240365

365,000/291,000

296,000

25-55

81%

4480

240400

400,000/331,000

328,000

25-55

82%

5522

300250

250,000/207,000

205,000

15-45

82%

4218

300365

365,000/291,000

296,000

25-55

81%

4480

300400

400,000/331,000

328,000

25-55

82%

5522

NOTE: All units are 2-stage gas heat.

HORIZONTAL SUPPLY — PROPANE

UNIT

HEATING INPUT

OUTPUT CAPACITY

TEMPERATURE

STEADY-STATE

MINIMUM

581A

(Btuh) Stage 2/Stage 1

(Btuh)

RISE (F)

EFFICIENCY %

HEATING CFM

210250

225,000/207,000

185,000

15-45

82%

3807

210365

329,000/291,000

266,000

25-55

81%

4480

210400

356,000/331,000

292,000

25-55

82%

4916

240250

225,000/207,000

184,500

15-45

82%

3796

240365

329,000/291,000

266,000

25-55

81%

4480

240400

356,000/331,000

292,000

25-55

82%

4916

300250

225,000/207,000

185,000

15-45

82%

3807

300365

329,000/291,000

266,000

25-55

81%

4480*

300400

356,000/331,000

292,000

25-55

82%

4920*

*7000 cfm minimum recommended above 1.0 in. wg external static pressure. NOTE: All units are 2-stage gas heat.