PHYSICAL DATA — 580F036-073 (cont)

 

 

 

580F036-

 

 

 

 

 

 

 

 

 

 

 

 

UNIT SIZE 580F

 

 

 

036

048

060

072

073

 

 

 

 

 

 

 

 

FURNACE SECTION

 

 

 

 

 

 

 

 

 

 

 

Rollout Switch Cutout

 

 

 

 

 

 

 

 

 

 

Temp (F)††

 

 

 

195

195

195

195

195

 

 

 

Burner Orifice Diameter

 

 

 

 

 

 

 

 

 

 

(in. ...drill size)

 

 

 

 

 

 

 

 

 

151

 

Natural Gas

 

Std

074

.113...33

.113...33

.113...33

.113...33

 

 

 

 

 

115

.113...33

.113...33

.113...33

.113...33

.113...33

 

 

 

 

 

150

.113...33

.129...30

.129...30

.129...30

.129...30

 

 

 

 

 

 

060N

.102...38

.102...38

 

 

 

 

 

 

090N

.102...38

.102...38

.102...38

 

 

 

 

 

 

 

 

 

 

 

 

120N

.102...38

.116...32

.116...32

 

 

 

Liquid Propane

 

Alt

074

.089...43

.089...43

.089...43

.089...43

 

 

 

 

 

 

115

.089...43

.089...43

.089...43

.089...43

.089...43

 

 

 

Thermostat Heat Anticipator

 

150

.089...43

.104...37

.104...37

.102...38

.104...37

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting (amps)

 

 

 

 

 

 

 

 

 

 

 

208/230 v and 575 Stage 1

 

 

.14

.14

.14

.14

.14

 

 

 

 

Stage 2

 

 

.14

.14

.14

.14

.14

 

 

 

460 v

Stage 1

 

 

.14

.14

.14

.14

.14

 

 

 

 

Stage 2

 

 

.14

.14

.14

.14

.14

 

 

 

Gas Input (Btuh)

Standard Units

 

074

—/74,000

—/74,000

—/74,000

—/74,000

 

 

 

 

(Stage 1/Stage 2)

 

115

—/74,000

—/115,000

—/115,000

—/115,000

—/115,000

 

 

 

 

 

 

150***

82,000/115,000

120,000/150,000

120,000/150,000

120,000/150,000

120,000/150,000

 

 

 

 

Low NOx Units

 

060N†††

60,000

60,000

 

 

 

 

 

 

090N†††

60,000

90,000

90,000

 

 

 

Efficiency (Steady

 

 

120N†††

90,000

120,000

120,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

State) (%)

 

 

 

80

80

80

80

80

 

 

 

Temperature Rise Range

 

074

15-45

15-45

15-45

15-45

 

 

 

 

 

 

115

15-45

35-65

35-65

35-65

35-65

 

 

 

 

 

 

150

55-85

50-80

50-80

50-80

50-80

 

 

 

 

 

 

060N

20-50

20-50

 

 

 

 

 

 

090N

20-50

30-60

30-60

 

 

 

Manifold Pressure (in. wg)

 

120N

30-60

40-70

40-70

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

 

Std

 

3.5

3.5

3.5

3.5

3.5

 

 

 

Liquid Propane

 

Alt

 

3.5

3.5

3.5

3.5

3.5

 

 

 

Gas Valve Quantity

 

 

 

1

1

1

1

1

 

 

 

Gas Valve Pressure Range

 

 

 

 

 

 

 

 

 

 

Psig

 

 

 

0.180-0.487

0.180-0.487

0.180-0.487

0.180-0.487

0.180-0.487

 

 

 

in. wg

 

 

 

5.0-13.5

5.0-13.5

5.0-13.5

5.0-13.5

5.0-13.5

 

 

 

Field Gas Connection

 

 

 

 

 

 

 

 

 

 

Size (in.)

 

 

 

1/

1/

1/

1/

1/

 

 

 

 

 

 

 

2

2

2

2

2

 

 

 

HIGH-PRESSURE SWITCH (psig)

 

 

 

 

 

 

 

 

 

 

Standard Compressor

 

 

 

450 ± 50

 

500 ± 50

500 ± 50

 

 

 

Internal Relief (Differential)

 

 

 

 

 

 

 

 

 

 

Cutout

 

 

 

 

428

 

428

428

 

 

 

Reset (Auto.)

 

 

 

 

320

 

320

320

 

 

 

LOW-PRESSURE SWITCH (psig)

 

 

 

 

 

 

 

 

 

 

Cutout

 

 

 

 

 

7 ± 3

 

 

 

 

 

Reset (Auto.)

 

 

 

 

 

22 ± 7

 

 

 

 

 

FREEZE PROTECTION

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT (F)

 

 

 

 

 

 

 

 

 

 

 

Opens

 

 

 

 

 

30 ± 5

 

 

 

 

 

Closes

 

 

 

 

 

45 ± 5

 

 

 

 

 

OUTDOOR-AIR INLET SCREENS

 

 

 

 

Cleanable

 

 

 

 

 

Quantity...Size (in.)

 

 

 

 

Varies by Option Selected

 

 

 

 

RETURN-AIR FILTERS

 

 

 

 

 

Throwaway

 

 

 

 

 

Quantity...Size (in.)

 

 

 

 

 

2...16 x 25 x 2

 

 

 

 

 

 

LEGEND

Al

Aluminum

Bhp

Brake Horsepower

Cu

Copper

*Evaporator coil fin material/condenser coil fin material. Contact your local repre- sentative for details about coated fins.

†Weight of 14-in. roof curb. **Single phase/three-phase.

††Rollout switch lockout is manually reset by interrupting power to unit or resetting thermostat.

***Three-phase standard high heat models have heating input values as shown. Single-phase standard high heat models have one-stage heating with heating input values as follows:

580F036 — 115,000 Btuh

580F048,060 — 150,000 Btuh

†††California SCAQMD compliant Low NOx models have combustion products that are controlled to 40 nanograms per joule or less.

NOTES:

1.High-static motor not available on single-phase units.

2.An LP kit is available as an accessory. Kit may be used at elevations as high as 2000 ft. LP kit is not used with Low NOx units.

21

Page 21
Image 21
Bryant 581A/B manual Furnace Section

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.