PERFORMANCE DATA

COOLING CAPACITIES — STANDARD UNITS

581A155 (12 Tons)

Temp (F)

 

 

 

 

 

 

 

 

 

 

 

Evap Air — Cfm/BF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3600/0.01

 

 

 

 

 

 

4375/0.01

 

 

 

 

 

 

5000/0.01

 

 

 

Air Ent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap Air — Ewb (F)

 

 

 

 

 

 

 

 

 

 

 

Cond

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54

58

62

 

67

 

72

76

80

54

58

62

 

67

 

72

76

80

54

58

62

 

67

 

72

76

80

 

TC

152

156

161

 

174

 

189

201

213

161

164

167

 

180

 

195

207

218

169

171

172

 

184

 

199

211

222

60

SHC

152

144

135

 

114

 

92.9

75.4

57.5

161

156

150

 

125

 

99.6

78.7

57.5

169

166

162

 

134

 

105

81.3

57.4

 

kW

7.56

7.65

7.74

 

8.01

 

8.33

8.6

8.86

7.76

7.82

7.88

 

8.14

 

8.46

8.72

8.97

7.92

7.95

7.98

 

8.24

 

8.55

8.82

9.06

 

TC

148

152

156

 

169

 

183

195

206

157

160

162

 

174

 

189

200

211

165

166

167

 

179

 

193

204

214

70

SHC

148

141

133

 

112

 

90.6

73.2

55.4

157

153

148

 

123

 

97.3

76.5

55.3

165

162

160

 

132

 

103

79.1

55.3

 

kW

8.5

8.58

8.67

 

8.97

 

9.26

9.53

9.8

8.7

8.75

8.81

 

9.07

 

9.39

9.66

9.91

8.86

8.89

8.91

 

9.16

 

9.49

9.76

9.99

 

TC

146

150

154

 

166

 

181

192

204

155

158

160

 

172

 

186

197

208

163

164

164

 

176

 

189

201

212

75

SHC

146

139

132

 

111

 

89.7

72.2

54.6

155

151

146

 

122

 

96.2

75.5

54.6

163

161

158

 

131

 

101

78.1

54.5

 

kW

9.02

9.1

9.18

 

9.45

 

9.8

10.1

10.4

9.22

9.27

9.31

 

9.58

 

9.91

10.2

10.5

9.39

9.41

9.43

 

9.68

 

9.99

10.3

10.6

 

TC

142

145

149

 

161

 

175

186

196

151

153

154

 

166

 

179

190

200

158

159

159

 

170

 

183

194

203

85

SHC

142

136

129

 

109

 

87.4

70

52.4

151

147

144

 

119

 

93.9

73.2

52.3

158

157

155

 

128

 

99.1

75.8

52.2

 

kW

10.1

10.2

10.3

 

10.6

 

10.9

11.2

11.5

10.3

10.4

10.4

 

10.7

 

11

11.3

11.6

10.5

10.5

10.5

 

10.8

 

11.1

11.4

11.7

 

TC

138

141

143

 

155

 

168

179

189

147

148

149

 

160

 

173

183

192

153

153

154

 

164

 

177

187

195

95

SHC

138

133

127

 

106

 

85

67.7

50.1

147

144

141

 

117

 

91.6

70.9

50

153

153

152

 

126

 

96.9

73.5

49.9

 

kW

11.4

11.4

11.5

 

11.8

 

12.2

12.4

12.7

11.6

11.6

11.6

 

11.9

 

12.3

12.6

12.8

11.8

11.8

11.8

 

12

 

12.4

12.7

12.9

 

TC

134

136

138

 

149

 

162

172

181

141

142

143

 

153

 

166

176

184

148

148

148

 

157

 

169

179

186

105

SHC

134

129

124

 

104

 

82.4

65.3

47.7

141

139

137

 

114

 

89

68.4

47.5

148

148

148

 

123

 

94.3

70.9

47.4

 

kW

12.7

12.8

12.8

 

13.2

 

13.5

13.8

14.1

12.9

13

13

 

13.3

 

13.6

13.9

14.2

13.1

13.1

13.1

 

13.4

 

13.7

14

14.3

 

TC

129

130

132

 

143

 

155

164

172

136

137

138

 

146

 

158

168

175

142

142

142

 

149

 

161

171

177

115

SHC

129

125

121

 

101

 

79.8

62.7

45.1

136

135

133

 

111

 

86.3

65.9

45

142

142

142

 

120

 

91.6

68.4

45

 

kW

14.2

14.2

14.3

 

14.6

 

15

15.3

15.6

14.4

14.4

14.5

 

14.7

 

15.1

15.5

15.7

14.6

14.6

14.6

 

14.8

 

15.2

15.6

15.7

 

TC

124

125

126

 

136

 

147

156

163

131

131

132

 

140

 

150

159

165

136

136

136

 

142

 

153

162

167

125

SHC

124

121

118

 

98.2

 

77

60.1

42.5

131

130

128

 

109

 

83.5

63.2

42.5

136

136

136

 

117

 

88.7

65.7

42.4

 

kW

15.8

15.8

15.9

 

16.2

 

16.6

17

17.2

16.1

16.1

16.1

 

16.4

 

16.7

17.1

17.3

16.3

16.2

16.2

 

16.4

 

16.8

17.2

17.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581A155 (12 Tons) (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

 

Evap Air — Cfm/BF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5625/0.02

 

 

 

 

 

 

6250/0.02

 

 

 

 

 

 

 

 

 

 

 

 

Air Ent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap Air — Ewb (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cond

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54

58

62

 

67

 

72

76

80

54

58

62

 

67

 

72

76

80

 

 

 

 

 

 

 

 

 

 

TC

175

175

176

 

187

 

202

214

224

180

180

180

 

190

 

204

216

226

 

 

 

 

 

 

 

 

 

60

SHC

175

173

171

 

142

 

110

83.8

57.3

180

180

180

 

151

 

115

86.2

57.2

 

 

 

 

 

 

 

 

 

 

kW

8.03

8.05

8.07

 

8.3

 

8.61

8.87

9.1

8.14

8.15

8.16

 

8.36

 

8.66

8.93

9.14

 

 

 

 

 

 

 

 

 

 

TC

170

171

171

 

181

 

195

207

216

175

176

176

 

184

 

198

209

218

 

 

 

 

 

 

 

 

 

70

SHC

170

169

168

 

140

 

108

81.5

55.2

175

176

176

 

148

 

113

84

55.1

 

 

 

 

 

 

 

 

 

 

kW

8.98

8.99

9.01

 

9.23

 

9.55

9.81

10

9.09

9.1

9.11

 

9.3

 

9.61

9.87

10.1

 

 

 

 

 

 

 

 

 

 

TC

168

168

169

 

179

 

192

203

213

173

173

173

 

181

 

195

206

215

 

 

 

 

 

 

 

 

 

75

SHC

168

167

166

 

139

 

107

80.5

54.4

173

173

173

 

147

 

112

83

54.3

 

 

 

 

 

 

 

 

 

 

kW

9.5

9.51

9.52

 

9.75

 

10.1

10.3

10.6

9.62

9.62

9.62

 

9.81

 

10.1

10.4

10.6

 

 

 

 

 

 

 

 

 

 

TC

163

163

164

 

172

 

185

196

205

168

168

168

 

175

 

188

198

206

 

 

 

 

 

 

 

 

 

85

SHC

163

162

162

 

136

 

104

78.2

52.2

168

168

168

 

145

 

109

80.6

52.1

 

 

 

 

 

 

 

 

 

 

kW

10.6

10.6

10.6

 

10.9

 

11.2

11.5

11.7

10.7

10.7

10.8

 

10.9

 

11.2

11.5

11.8

 

 

 

 

 

 

 

 

 

 

TC

158

158

158

 

166

 

178

189

196

162

162

162

 

168

 

180

190

197

 

 

 

 

 

 

 

 

 

95

SHC

158

157

157

 

134

 

102

75.9

49.8

162

162

162

 

142

 

107

78.3

49.7

 

 

 

 

 

 

 

 

 

 

kW

11.9

11.9

11.9

 

12.1

 

12.4

12.7

12.9

12

12

12

 

12.1

 

12.5

12.8

13

 

 

 

 

 

 

 

 

 

 

TC

152

152

152

 

159

 

171

181

187

157

157

157

 

161

 

173

182

188

 

 

 

 

 

 

 

 

 

105

SHC

152

152

152

 

131

 

99.3

73.3

47.4

157

157

157

 

139

 

104

75.7

47.4

 

 

 

 

 

 

 

 

 

 

kW

13.2

13.2

13.2

 

13.4

 

13.8

14.1

14.3

13.4

13.4

13.4

 

13.5

 

13.9

14.2

14.4

 

 

 

 

 

 

 

 

 

 

TC

146

146

146

 

151

 

163

172

177

150

150

150

 

153

 

165

174

178

 

 

 

 

 

 

 

 

 

115

SHC

146

146

146

 

128

 

96.6

70.7

44.9

150

150

150

 

136

 

102

73.1

44.8

 

 

 

 

 

 

 

 

 

 

kW

14.7

14.7

14.7

 

14.9

 

15.3

15.6

15.8

14.9

14.9

14.9

 

14.9

 

15.4

15.7

15.8

 

 

 

 

 

 

 

 

 

 

TC

140

140

140

 

144

 

155

163

167

144

144

144

 

146

 

156

164

168

 

 

 

 

 

 

 

 

 

125

SHC

140

140

140

 

125

 

93.7

67.9

42.4

144

144

144

 

133

 

98.7

70.2

42.3

 

 

 

 

 

 

 

 

 

 

kW

16.4

16.4

16.4

 

16.5

 

16.9

17.2

17.4

16.5

16.5

16.5

 

16.6

 

17

17.3

17.4

 

 

 

 

 

 

 

 

 

581A155-300

LEGEND

BF — Bypass Factor

Edb — Entering Dry-Bulb

Ewb — Entering Wet-Bulb

kW

Compressor Motor Power Input

ldb

Leaving Dry-Bulb

lwb

Leaving Wet-Bulb

SHC —

Sensible Heat Capacity (1000 Btuh) Gross

TC

Total Capacity (1000 Btuh) Gross

NOTES:

 

1. Direct interpolation is permissible. Do not extrapolate.

2. The following formulas may be used:

tldb

= tedb

 

sensible capacity (Btuh)

 

 

 

1.10 x cfm

 

 

 

 

 

tlwb

= Wet-bulb temperature corresponding to enthalpy of air leaving evapo-

 

 

rator coil (hlwb)

hlwb

= hewb

total capacity (Btuh)

 

4.5 x cfm

 

 

 

 

 

Where: hewb = Enthalpy of air entering evaporator coil

3.The SHC is based on 80 F edb temperature of air entering evaporator coil. Below 80 F edb, subtract (corr factor x cfm) from SHC.

Above 80 F edb, add (corr factor x cfm) to SHC.

BYPASS

 

ENTERING AIR DRY-BULB TEMP (F)

79

78

77

 

76

75

 

under 75

FACTOR

 

 

81

82

83

 

84

85

 

over 85

(BF)

 

 

 

 

 

 

 

Correction

Factor

 

 

.05

1.04

2.07

3.11

 

4.14

5.18

 

 

.10

.98

1.96

2.94

 

3.92

4.90

 

Use formula

.20

.87

1.74

2.62

 

3.49

4.36

 

shown below.

.30

.76

1.53

2.29

 

3.05

3.82

 

 

Interpolation is permissible.

Correction Factor = 1.10 x (1 – BF) x (edb – 80).

4. Use chart below for bypass factor.

 

 

 

ENTERING WET-BULB (F)

 

 

CFM

54

58

62

67

72

76

80

 

 

 

Bypass Factor

 

 

3600

0.355

0.158

0.054

0.038

0.049

0.000

0.000

4375

0.439

0.255

0.112

0.043

0.057

0.000

0.000

5000

0.486

0.314

0.126

0.054

0.037

0.000

0.000

5625

0.525

0.360

0.174

0.066

0.073

0.000

0.000

6250

0.551

0.410

0.202

0.080

0.079

0.000

0.000

208

Page 208
Image 208
Bryant 581A/B manual Cooling Capacities Standard Units, Entering WET-BULB F CFM

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.