Bryant 581A/B manual 581B036-150 Units, 121/2 Tons

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 134
Image 134

ELECTRICAL DATA (cont)

581B036-150 UNITS

 

 

 

UNIT SIZE

NOMINAL

 

CONV

VOLTAGE

COMPRESSOR (each)

OFM (each)

IFM

COMBUSTION

POWER SUPPLY*

MINIMUM UNIT

 

 

 

IFM TYPE

RANGE

FAN MOTOR

DISCONNECT SIZE†

 

 

 

581B

V-PH-Hz

OUTLET

 

 

 

 

 

FLA

 

 

 

 

 

 

 

 

 

Min

Max

Qty

RLA

LRA

Qty

FLA

 

FLA

MCA

MOCP**

FLA

LRA

 

 

 

 

 

STD

NO

 

 

 

 

 

 

 

7.5

 

40.2

45

42

276

 

 

 

 

208/230-3-60

YES

187

254

2

13.1

105

2

1.4

0.6

46.2

50

48

281

 

 

 

 

 

 

 

 

 

 

HIGH

NO

10.6

43.3

50

46

301

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

49.3

60

51

305

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

NO

 

 

 

 

 

 

 

3.4

 

21.5

25

23

143

 

 

 

 

460-3-60

YES

414

508

2

7.4

55

2

0.7

0.3

24.2

30

25

145

 

 

 

 

 

 

 

 

 

102

HIGH

NO

4.8

22.9

25

24

156

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(81/2 Tons)

 

YES

 

 

 

 

 

 

 

 

25.6

30

27

158

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

NO

 

 

 

 

 

 

 

2.8

 

18.2

20

19

115

 

 

 

 

 

YES

 

 

 

 

 

 

0.6

0.3

20.4

25

21

116

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575-3-60

HIGH

NO

518

632

2

6.4

44

2

3.3

18.9

25

20

124

 

 

 

 

 

 

 

 

 

 

YES

 

 

21.1

25

22

126

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PH

NO

 

 

 

 

 

 

0.7

4.8

0.3

19.4

25

20

124

 

150

 

 

 

YES

 

 

 

 

 

 

21.5

25

22

126

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

NO

 

 

 

 

 

 

 

10.6

0.6

53.0

60

56

341

 

 

 

 

 

 

 

 

 

 

 

 

 

581B036-

 

 

208/230-3-60

YES

187

254

2

17.6

125

2

1.4

59.0

70

61

345

 

 

 

 

 

 

 

 

120

 

NO

 

 

27.5

30

29

182

 

 

 

 

 

HIGH

NO

 

 

 

 

 

 

 

15.0

0.6

57.4

70

61

364

 

 

 

 

 

YES

 

 

 

 

 

 

 

63.4

70

66

369

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

NO

 

 

 

 

 

 

 

4.8

 

24.9

30

26

171

 

 

 

 

460-3-60

YES

414

508

2

8.3

62.5

2

0.7

0.3

27.6

30

29

173

 

 

 

 

 

 

 

 

 

(10 Tons)

HIGH

 

7.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

30.2

35

32

184

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

NO

 

 

 

 

 

 

 

3.3

0.3

19.1

25

20

136

 

 

 

 

 

 

YES

 

 

 

 

 

2

0.6

 

 

21.3

25

22

138

 

 

 

 

575-3-60

HIGH

NO

518

632

2

6.3

50

5.6

0.3

21.0

25

23

146

 

 

 

 

 

 

 

 

 

 

YES

 

 

23.1

25

25

148

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PH

NO

 

 

 

 

 

2

0.7

7.4

0.3

21.2

25

23

146

 

 

 

 

 

YES

 

 

 

 

 

23.4

25

25

148

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-3-60

STD

NO

187

254

2

19

156

2

1.4

15.0

0.6

60.6

70

64

426

 

 

 

 

YES

66.6

70

70

431

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460-3-60

STD

NO

414

508

2

9

75

2

0.7

7.4

0.3

29.1

35

31

207

 

 

 

150

YES

31.8

35

33

209

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(121/2 Tons)

 

ST

NO

 

 

 

 

 

2

0.6

5.6

0.3

23.5

30

25

154

 

 

 

 

575-3-60

YES

518

632

2

7.4

54

25.6

30

27

156

 

 

 

 

 

 

 

 

 

 

 

 

 

PH

NO

2

0.7

7.4

0.3

23.7

30

25

154

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

25.9

30

27

156

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

Determine percent of voltage imbalance.

CONV

Convenience Outlet

FLA

Full Load Amps

% Voltage Imbalance = 100 x

7

HACR

Heating, Air Conditioning and Refrigeration

IFM

Indoor (Evaporator) Fan Motor

LRA

Locked Rotor Amps

MCA

Minimum Circuit Amps

MOCP

Maximum Overcurrent Protection

NEC

National Electrical Code

OFM

Outdoor (Condenser) Fan Motor

PH

Perfect Humidity™ Dehumidification System

RLA

Rated Load Amps

UL

Underwriters’ Laboratories

*The values listed in this table do not include power exhaust. See table at right for power exhaust requirements.

†Used to determine minimum disconnect per NEC. **Fuse or HACR circuit breaker.

NOTES:

1.In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker. The UL, Canada units may be fuse or circuit breaker.

2.Electrical data based on 95 F ambient outdoor-air temperature ± 10% voltage.

3.Unbalanced 3-Phase Supply Voltage

Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance.

max voltage deviation from average voltage

= 100 x

average voltage

Example: Supply voltage is 460-3-60.

AB = 452 v

BC = 464 v

AC = 455 v

452 + 464 + 455

Average Voltage =

3

1371

=

3

= 457

Determine maximum deviation from average voltage. (AB) 457 – 452 = 5 v

(BC) 464 – 457 = 7 v (AC) 457 – 455 = 2 v

Maximum deviation is 7 v.

457

= 1.53%

This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.

IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

POWER EXHAUST ELECTRICAL DATA

 

 

 

 

 

MOCP

POWER EXHAUST

APPLICATION

MCA

MCA

MCA

(separate

PART NO.

USAGE

(230 V)

(460 V)

(575 V)

power source

 

 

 

 

 

only)

CRPWREXH030A01

036-072*

1.6

N/A

0.64

15

CRPWREXH021A01

036-072

N/A

0.68

N/A

15

CRPWREXH022A01

090-150*

3.4

N/A

1.32

15

CRPWREXH023A01

090-150

N/A

1.4

N/A

15

CRPWREXH028A01

ALL*

1.7

N/A

0.68

15

CRPWREXH029A01

ALL

N/A

0.7

N/A

15

N/A — Not Available *Single or three phase.

NOTE: If a single power source is to be used, size wire to include power exhaust MCA and MOCP.

Check MCA and MOCP when power exhaust is powered through the unit. Determine the new MCA including the power exhaust using the following formula:

MCA New = MCA unit only + MCA of Power Exhaust

For example, using a 581B060 unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A01 power exhaust.

MCA New = 28.9 amps + 1.6 amps = 30.5 amps

If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP in this example is 35 amps and the MCA New is below 35; therefore the MOCP is acceptable. If “MCA New” is larger than the published MOCP, raise the MOCP to the next larger size. For separate power, the MOCP for the power exhaust will be 15 amps per NEC.

134

Page 134
Image 134
Bryant 581A/B manual 581B036-150 Units, 121/2 Tons

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.