Bryant 581A/B Application Data, Concentric Duct Details, Condenser Coil Protection Applications

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 264
Image 264

APPLICATION DATA (cont)

CONCENTRIC DUCT DISTRIBUTION

CONCENTRIC DUCT DETAILS

1'-10 11/16''

6'-2 3/8'' MAX.

MAX.

5'-9 3/16'' MAX.

5 3/16''

1'-0 3/16''

4'-6 13/16'' 1'-7 15/16''

1'-0 3/16''

24'' MIN.

B

B

A

a48-7482

NOTE: Do not drill in this area, damage to basepan may result in water leak.

A

a50-530

BAFFLE

Shaded area indicates block-off panels.

NOTE: Dimensions A, Aand B, Bare obtained from field-supplied ceiling diffuser.

Concentric Duct Details

c.E-COATED ALUMINUM FIN coils undergo a precisely controlled scientific process that bonds an impermeable epoxy coating to the specially prepared fin coil surface. E-Coating produces a smooth, consistent coating that is less brittle, more resilient and more durable than previ- ous postcoating processes. E-Coated aluminum-fin coils offer economical protection and improved coil life in many contaminated environments.

d.E-COATEDCOPPER-FIN COILS provide maximum pro- tection in virtually all environments, this option combines the continuous, impenetrable barrier of the E-Coating process with the natural resistance of an all-copper con- struction. E-Coated copper-fin coil assemblies ensure long life, even in environments that combine harsh coastal conditions with industrial contamination.

16.ECONOMI$ER IV — The EconoMi$er IV factory-installed economizer package includes a gear-driven damper sys- tem that modulates the return air and outdoor air supply to the rooftop unit in order to take advantage of “free cooling” with outdoor air when conditions are suitable. The system utilizes industry proven technology available for integrating the use of outdoor air for cooling with mechanical cooling for 3 through 25-ton rooftop units. The intuitive EconoMi$er IV microprocessor-based controller optimizes

and enhances rooftop operation through reduced energy consumption, optimal zone comfort, and efficient equip- ment cycling. This is accomplished by operating the com- pressors when the outdoor air temperature is too warm, integrating the compressors with outdoor air when free cooling is available, and locking out the compressor when outdoor air temperature is too cold. The detailed sequence of operation is described in the Controls section with a brief description of selected application items here.

a.THERMOSTAT INTERFACE — The EconoMi$er IV con- trol was designed to work with conventional thermostats that have Y1 (cooling stage 1), Y2 (cooling stage 2), W1 (heat stage 1), W2 (heat stage 2), and G (fan). In addi- tion, the EconoMi$er IV will support an occupied/ unoccupied switch (typically integrated into the thermo- stat or Thermidistat™ device). When the switch is closed, it provides a 24-vac signal to the unit for occu- pied mode, and provides no signal to indicate unoccu- pied mode. The EconoMi$er IV control can be configured to allow different minimum economizer damper positions and to allow the use of mechanical cooling in the occupied mode.

CONDENSER COIL PROTECTION APPLICATIONS

 

DESCRIPTION

 

 

 

 

ENVIRONMENT

 

 

 

 

(Dura-Shield Option)

Standard, Non-Corrosive

 

Mild Coastal

 

Severe Coastal

Industrial

 

Combined Coastal

 

 

 

 

 

 

 

 

 

 

and Industrial

Standard, Al/Cu

 

X

 

 

 

 

 

 

 

Pre-Coated Al/Cu

 

 

 

X

 

 

 

 

 

Cu/Cu

 

 

 

X

 

 

 

 

 

E-Coated Al/Cu

 

 

 

 

 

 

X

 

X

E-Coated Cu/Cu

 

 

 

 

 

X

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

Al/Cu

Aluminum Fin with Copper Tube Coil

E-Coated

Extremely Flexible and Durable Epoxy Coating Uniformly

 

Cu/Cu

Copper Fin with Copper Tube Coil

 

 

Applied to the Coil Surfaces

 

 

 

Dura-Shield

Family of Coil Protection Options

Pre-Coated

Epoxy Coating Applied to Fin Stock Material

 

264

Page 264
Image 264
Bryant 581A/B Application Data, Concentric Duct Details, Condenser Coil Protection Applications, Description Environment

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.