Bryant 581A/B manual FAN Performance 579F180-300 Units

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 161
Image 161

PERFORMANCE DATA — 579F (cont)

FAN PERFORMANCE — 579F180-300 UNITS (cont)

579F300275 (25 TONS) *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

 

0.6

 

 

 

0.8

 

 

1.0

 

 

1.2

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

Rpm

 

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

7,000

941

 

3.35

2,769

1002

3.80

 

3,140

1061

 

4.27

3528

1117

 

4.76

3,934

1171

5.27

4,356

1224

5.80

4,794

 

7,500

999

 

4.05

3,348

1057

4.53

 

3,742

1112

 

5.02

4152

1166

 

5.54

4,579

1218

6.07

5,216

1268

6.63

5,478

 

8,000

1058

 

4.85

4,007

1113

5.35

 

4,424

1165

 

5.87

4856

1216

 

6.41

5,304

1266

6.97

5,766

1314

7.55

6,243

 

8,500

1117

 

5.74

4,750

1169

6.28

 

5,190

1219

 

6.83

5645

1268

 

7.40

6,114

1315

7.98

6,597

1361

8.58

7,094

 

9,000

1177

 

6.75

5,583

1226

7.31

 

6,047

1274

 

7.89

6524

1320

 

8.48

7,015

1365

9.09

7,520

1410

9.72

8,037

 

9,500

1237

 

7.98

6,511

1284

8.46

 

6,999

1329

 

9.07

7499

1374

 

9.69

8,012

1417

10.33

8,538

1459

10.98

9,076

 

10,000

1297

 

9.12

7,450

1342

9.74

 

8,051

1385

 

10.37

8574

1428

 

11.02

9,110

1469

11.68

9,657

1510

12.36

10,217

 

10,500

1358

 

10.49

8,674

1400

11.14

 

9,209

1442

 

11.80

9755

1483

 

12.47

10,314

1523

13.16

10,883

 

11,000

1418

 

12.00

9,919

1459

12.67

 

10,478

 

 

 

11,250

1449

 

12.80

10,585

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F300275 (25 TONS) * (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.4

 

 

1.6

 

 

 

 

1.8

 

 

 

 

 

 

 

 

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

Rpm

 

Bhp

Watts

 

 

 

 

 

 

 

 

 

 

 

7,000

1274

 

6.35

5248

1323

6.92

 

5,718

1371

 

5.54

6204

 

 

 

 

 

 

 

 

 

 

 

7,500

1316

 

7.20

6960

1364

7.79

 

6,437

1410

 

6.41

6939

 

 

 

 

 

 

 

 

 

 

 

8,000

1360

 

8.14

6734

1406

8.76

 

7,239

1450

 

7.40

7759

 

 

 

 

 

 

 

 

 

 

 

8,500

1406

 

9.20

7605

1449

9.83

 

8,129

1492

 

8.48

8666

 

 

 

 

 

 

 

 

 

 

 

9,000

1453

 

10.36

8568

1495

11.02

 

9,111

1536

 

9.69

9667

 

 

 

 

 

 

 

 

 

 

 

9,500

1501

 

11.64

9627

1541

12.32

 

10,190

 

 

 

 

 

 

 

 

 

 

 

 

10,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10,500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11,250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

Refer to page 162 for general Fan Performance Data notes.

 

 

Bhp

Brake Horsepower

 

 

 

 

 

 

 

 

NOTE: Maximum continuous bhp is 10.20 (208/230 and 575 v) or 11.80 (460 v)

Watts — Input Watts to Motor

 

 

 

 

 

 

 

 

and the maximum continuous watts are 9510 (208/230 and 575 v) or 11,000

*Standard low-medium static drive range is 1066 to 1283 rpm. Alternate high-

(460 v). Do not adjust motor rpm such that motor maximum bhp and/or watts is

exceeded at the maximum operating cfm.

 

 

 

 

static drive range is 1332 to 1550. Other rpms require a field-supplied drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F180300 (15 TONS)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

 

0.6

 

 

 

0.8

 

 

1.0

 

 

1.2

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

Rpm

 

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

4500

819

 

1.55

1335

914

1.76

 

1518

1001

 

1.98

1705

1083

 

2.20

1894

1160

2.42

2088

1234

2.65

2284

 

4800

861

 

1.78

1538

951

2.00

 

1726

1035

 

2.22

1916

1113

 

2.45

2110

1188

2.68

2307

1259

2.91

2507

 

5100

904

 

2.04

1759

989

2.26

 

1952

1069

 

2.49

2147

1145

 

2.72

2345

1218

2.95

2545

1287

3.17

2749

 

5400

947

 

2.32

1999

1300

2.55

 

2197

1105

 

2.78

2396

1179

 

3.01

2598

1248

3.25

2802

1315

3.49

3009

 

5700

990

 

2.62

2259

1068

2.85

 

2461

1142

 

3.09

2665

1213

 

3.33

2871

1280

3.57

3079

1345

3.81

3289

 

6000

1034

 

2.94

2539

1109

3.18

 

2745

1180

 

3.42

2953

1248

 

3.67

3163

1313

3.91

3375

1376

4.16

3589

 

6300

1078

 

3.29

2840

1150

3.54

 

3050

1218

 

3.78

3262

1284

 

4.03

3476

1348

4.28

3692

 

6600

1123

 

3.67

3161

1192

3.91

 

3376

1258

 

4.16

3592

 

 

6900

1167

 

4.06

3504

1234

4.32

 

3723

 

 

 

7200

 

 

 

 

 

7500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F180300 (15 TONS) * (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

1.4

 

 

1.6

 

 

 

 

1.8

 

 

 

1.9

 

 

2.0

 

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

Rpm

 

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

 

4500

1304

 

2.88

2484

1371

3.12

 

2688

1435

 

3.36

2895

1467

 

3.48

2999

1497

3.60

3104

 

 

 

 

4800

1327

 

3.14

2711

1393

3.38

 

2917

1456

 

3.62

3126

1486

 

3.75

3232

1517

3.87

3338

 

 

 

 

5100

1353

 

3.43

2955

1417

3.67

 

3165

1478

 

3.92

3377

1508

 

4.04

3484

1537

4.16

3592

 

 

 

 

5400

1380

 

3.73

3219

1442

3.98

 

3432

1502

 

4.23

3646

1531

 

4.35

3755

 

 

 

 

5700

1408

 

4.06

3503

1468

4.31

 

3718

 

 

 

 

 

 

6000

 

 

 

 

 

 

 

 

6300

 

 

 

 

 

 

 

 

6600

 

 

 

 

 

 

 

 

6900

 

 

 

 

 

 

 

 

7200

 

 

 

 

 

 

 

 

7500

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

Refer to page 162 for general Fan Performance Data notes.

 

 

Bhp

Brake Horsepower

 

 

 

 

 

 

 

 

NOTE: Maximum continuous bhp is 4.25 (208/230 v and 460 v) or 3.45 (575 v)

Watts — Input Watts to Motor

 

 

 

 

 

 

 

 

and the maximum continuous watts are 3775 (208/230 v and 460 v) or 3065

*Standard low-medium static drive range is 891 to 1179 rpm (208/230 v and

(575 v). Do not adjust motor rpm such that motor maximum bhp and/or watts is

exceeded at the maximum operating cfm.

 

 

 

 

460 v) or 1159 to 1429 (575 v). Alternate high-static drive range is 1227 to 1550

 

 

 

 

 

 

 

 

 

 

 

(208/230 v and 460 v only). Other rpms require a field-supplied drive.

579F180-300

161

Page 161
Image 161
Bryant 581A/B manual FAN Performance 579F180-300 Units

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.