Bryant 581A/B manual 581B036-150

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 84
Image 84

581B036-150

PHYSICAL DATA — 581B036-072 (cont)

UNIT SIZE 581B

 

036

048

 

060

072

FURNACE SECTION

 

 

 

 

 

 

 

 

 

Rollout Switch Cutout Temp (F)†

 

195

195

 

195

195

Burner Orifice Diameter (in. ...drill size)**

 

 

 

 

 

 

 

 

 

Natural Gas — Std

071/072

.113...33

.113...33

 

.113...33

.113...33

 

114/115

.113...33

.113...33

 

.113...33

.113...33

 

149/150

.129...30

 

.129...30

.129...30

 

060N

.102...38

.102...38

 

.102...38

 

090N

.102...38

.102...38

 

.102...38

 

120N

.116...32

 

.116...32

Liquid Propane — Alt††

071/072

.089...43

.089...43

 

.089...43

.089...43

 

114115

.089...43

.089...43

 

.089...43

.089...43

Thermostat Heat Anticipator Setting (amps)

149/150

.102...38

 

.102...38

.102...38

 

 

 

 

 

 

 

 

 

208/230/460 v

 

 

 

 

 

 

 

 

 

First Stage

 

.14

.14

 

.14

.14

Second Stage

 

.14

.14

 

.14

.14

Gas Input (Btuh)

 

 

 

 

 

 

 

 

 

First Stage/Second Stage (3-phase units)

072

50,000/ 72,000

50,000/ 72,000

 

50,000/ 72,000

50,000/ 72,000

 

115

82,000/115,000

82,000/115,000

 

82,000/115,000

82,000/115,000

 

150

120,000/150,000

 

120,000/150,000

120,000/150,000

 

071II

—/ 72,000

—/ 72,000

 

—/ 72,000

 

114II

—/115,000

—/115,000

 

—/115,000

 

149II

—/150,000

 

—/150,000

 

060N***

—/ 60,000

—/ 60,000

 

—/ 60,000

 

090N***

—/ 90,000

—/ 90,000

 

—/ 90,000

 

120N***

—/120,000

 

—/120,000

Efficiency (Steady State) (%)

072

82

82

 

82

82

 

115

80

81

 

81

81

 

150

80

 

80

80

 

071

82

82

 

82

 

114

80

81

 

81

 

149

80

 

80

 

060N

80

80

 

80

 

090N

80

80

 

80

 

120N

80

 

80

Temperature Rise Range

072

25-55

25-55

 

25-55

25-55

 

115

55-85

35-65

 

35-65

35-65

 

150

50-80

 

50-80

50-80

 

071

25-55

25-55

 

25-55

 

114

55-85

35-65

 

35-65

 

149

50-80

 

50-80

 

060N

20-50

20-50

 

20-50

 

090N

30-60

30-60

 

30-60

Manifold Pressure (in. wg)

120N

40-70

 

40-70

 

 

 

 

 

 

 

 

 

Natural Gas — Std

 

3.5

3.5

 

3.5

3.5

Liquid Propane — Alt††

 

3.5

3.5

 

3.5

3.5

Maximum Static Pressure (in. wg)

 

1.0

1.0

 

1.0

1.0

Field Gas Connection Size (in.)

 

1/

2

1/

2

 

1/

2

1/

 

 

 

 

 

 

2

HIGH-PRESSURE SWITCH (psig)

 

 

 

 

 

 

 

 

 

Standard Compressor Internal Relief

 

 

 

 

450 ± 50

 

 

 

Cutout

 

 

 

 

428

 

 

 

Reset (Auto.)

 

 

 

 

320

 

 

 

LOSS-OF-CHARGE SWITCH/LOW-PRESSURE

 

 

 

 

 

 

 

 

 

SWITCH (Liquid LIne) (psig)

 

 

 

 

 

 

 

 

 

Cutout

 

 

 

 

7 ± 3

 

 

 

Reset (Auto.)

 

 

 

 

22 ± 5

 

 

 

FREEZE PROTECTION THERMOSTAT

 

 

 

 

 

 

 

 

 

Opens (F)

 

 

 

 

30 ± 5

 

 

 

Closes (F)

 

 

 

 

45 ± 5

 

 

 

OUTDOOR-AIR INLET SCREENS

 

 

 

 

Cleanable

 

 

Quantity...Size (in.)

 

 

 

Varies By Option Selected

 

RETURN-AIR FILTERS

 

 

 

 

Throwaway

 

 

Quantity...Size (in.)

 

 

 

2...16 x 25 x 2

 

 

4...16 x 16 x 2

LEGEND

Bhp — Brake Horsepower

*Single phase/three phase. †Indicates automatic reset.

**60,000 and 72,000 Btuh heat input units have 2 burners. 90,000 and 120,000 Btuh heat input units have 3 burners. 115,000 Btuh heat input units and 150,000 Btuh Heat input units have 3 burners.

††An LP kit is available as an accessory. In order to convert a Low NOx unit to LP gas, the baffle must be removed. Low NOx units converted to LP gas are no longer California SCAQMD compliant.

California compliant three-phase models.

***California SCAQMD compliant low NOx models have combustion products that are controlled to 40 nanograms per joule or less.

84

Page 84
Image 84
Bryant 581A/B manual 581B036-150

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.