ARI* CAPACITY RATINGS — 580F036-151

 

 

NOMINAL

STANDARD

 

NET COOLING

TOTAL

 

 

 

SEER†

 

SOUND

UNIT 580F

 

CAPACITY

 

 

 

 

 

 

 

RATING

TONS

CFM

 

 

kW

 

Belt Drive

 

Direct Drive

 

 

 

 

(Btuh)

 

 

 

 

(dB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

 

3

 

1200

 

35,000

4.0

 

10.0

 

 

9.7

 

81

048

 

4

 

1600

 

47,000

5.3

 

10.0

 

 

9.7

 

81

060

 

5

 

2000

 

57,000

6.7

 

10.0

 

 

9.7

 

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

NOMINAL

 

NET COOLING

 

TOTAL

 

 

 

 

 

SOUND

 

 

 

 

 

CAPACITY

 

 

 

EER

 

RATING

 

IPLV

580F

 

TONS

 

 

kW

 

 

 

 

 

 

(Btuh)

 

 

 

 

 

 

 

(dB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

072

 

6

 

72,000

 

 

8.0

 

 

9.0

 

81

 

**

073

 

6

 

71,000

 

 

7.0

 

 

10.1

 

80

 

**

090

 

71/2

 

85,000

 

 

9.6

 

 

8.9

 

87

 

9.40

091

 

71/2

 

88,000

 

 

8.7

 

 

10.1

 

82

 

10.5

103

 

81/2

 

100,000

 

 

9.9

 

 

10.1

 

82

 

10.4

120

 

10

 

117,000

 

 

13.0

 

 

9.0

 

88

 

9.40

121

 

10

 

114,000

 

 

11.3

 

 

10.1

 

84

 

11.0

150

 

121/2

 

144,000

 

 

16.0

 

 

9.0

 

87

 

9.20

151

 

121/2

 

136,000

 

 

14.3

 

 

9.5

 

86

 

9.70

 

 

LEGEND

dB

Sound Levels (decibels)

db

Dry Bulb

EER

Energy Efficiency Ratio

IPLV

Integrated Part-Load Values

SEER —

Seasonal Energy Efficiency Ratio

wb

Wet Bulb

*Air Conditioning and Refrigeration Institute.

†Applies only to units with capacity of 65,000 Btuh or less. **The IPLV applies only to two-stage cooling units.

NOTES:

1.Rated in accordance with ARI Standards 210/240 (for sizes 036- 120) or 360, (for size 150 and 151) and 270.

2.ARI ratings are net values, reflecting the effects of circulating fan heat.

3.Ratings are based on:

Cooling Standard: 80 F db, 67 F wb indoor entering-air tempera- ture and 95 F db air entering outdoor unit.

IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F db outdoor entering-air temperature.

4.All 580F036, 048, 060, 073, 091, 103, 121, 151 units are in com- pliance with ASHRAE 90.1-1999 Energy Standard for minimum SEER and EER requirements. Refer to state and local codes or visit the following website: http://solstice.crest.org/efficiency/bcap to determine if compliance with this standard pertains to a given geographical area of the United States.

5.All 581B036-120 units are in compliance with Energy Star high efficiency requirements.

HEATING CAPACITIES AND EFFICIENCIES (Standard-Efficiency Units) — 580F036-151

208/230-1-60SINGLE-STAGE GAS HEAT

UNIT

INPUT

OUTPUT

TEMPERATURE

MINIMUM HEATING

 

EFFICIENCY

580F

CAPACITY

CAPACITY

RISE (°F)

AIRFLOW (CFM)

AFUE (%)

 

Steady State (%)

036074

74,000

57,000

25-55

1004

80

 

80

036115

115,000

89,000

55-85

1002

80

 

80

048074

74,000

57,000

25-55

1004

80

 

80

048115

115,000

91,000

35-65

1327

80

 

80

048150

150,000

118,000

50-80

1396

80

 

80

060074

74,000

57,000

25-55

1004

80

 

80

060115

115,000

91,000

35-65

1327

80

 

80

060150

150,000

118,000

50-80

1314

80

 

80

208/230-1-60SINGLE-STAGE GAS HEAT — LOW NOx

UNIT

INPUT

OUTPUT

TEMPERATURE

MINIMUM HEATING

 

EFFICIENCY

580F

CAPACITY

CAPACITY

RISE (°F)

AIRFLOW (CFM)

AFUE (%)

 

Steady State (%)

036060N

60,000

49,000

20-50

910

80

 

80

036090N

90,000

73,000

30-60

1130

80

 

80

048060N

60,000

49,000

20-50

910

80

 

80

048090N

90,000

73,000

30-60

1130

80

 

80

048120N

120,000

98,000

40-70

1300

80

 

80

060060N

60,000

49,000

20-50

910

80

 

80

060090N

90,000

73,000

30-60

1130

80

 

80

060120N

120,000

98,000

40-70

1300

80

 

80

8

Page 8
Image 8
Bryant 581A/B manual ARI* Capacity Ratings 580F036-151

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.