580F036-151

TYPICAL WIRING SCHEMATICS — 580F036-151 (cont)

a48-7910

LEGEND

NOTE:

 

ECONOMIZER NOTES:

IAQ — Indoor Air Quality

Potentiometer Defaults Settings:

1.

620 ohm, 1 watt 5% resister should be removed only when using differential

Power Exhaust

Middle

 

enthalpy or dry bulb.

LA — Low Ambient Lockout Device

 

Minimum Pos.

Fully Closed

2.

If a separate field supplied 24v transformer is used for the IAQ sensor

POT — Potentiometer

DCV Max.

Middle

 

power supply, it cannot have the secondary of the transformer grounded.

OAT — Outdoor-Air Temperature

 

DCV Set

Middle

3.

For field installed remote minimum position POT, remove black wire jumper

RAT — Return-Air Temperature

Enthalpy

C Setting

 

between P and P1 and set control minimum position POT to the minimum

 

 

position.

EconoMi$er IV Wiring — 580F036-151 Units

500OHM

RESISTOR

VIOLET

NOTE 1

PINK

RUN

NOTE 2

-

+

50HJ540573

ACTUATOR

ASSEMBLY

OPTIONAL CO2 SENSOR 4 - 20 mA

OUTPUT

DIRECT DRIVE

ACTUATOR

a48-8209

NOTES:

1.Switch on actuator must be in run position for economizer to operate.

2.50HJ540573 actuator consists of the 50HJ540567 actuator and a harness with 500-ohm resistor.

EconoMi$er2 Wiring — 580F036-151 Units

YELLOW

BLACK

4

3

5

BLUE

2

8

6

7

RED

1

10

11

9

WHITE

12

ECONOMISER2 PLUG

80

Page 80
Image 80
Bryant 581A/B manual Typical Wiring Schematics 580F036-151, EconoMi$er IV Wiring 580F036-151 Units

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.