PERFORMANCE DATA — 579F (cont)

COOLING CAPACITIES (cont)

 

 

 

 

579F240 (20 Tons)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

Evaporator Air Quantity — Cfm

 

 

 

 

 

 

 

 

 

Air Entering

 

 

 

 

6,000

 

 

 

 

 

 

7,000

 

 

 

 

 

 

 

Condenser

 

 

 

 

 

 

Evaporator Air — Ewb (F)/BF

 

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54/0.48

58/0.31

62/0.21

67/0.19

72/0.17

76/0.22

80/0.05

54/0.54

58/0.37

62/0.25

67/0.21

72/0.19

76/0.21

80/0.04

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

217

222

232

252

274

294

316

227

231

238

254

281

297

322

 

 

 

 

75

SHC

 

217

199

189

163

136

112

90

227

217

202

172

143

115

91

 

 

 

 

 

kW

 

15.1

15.2

15.4

15.8

16.2

16.6

17.0

15.3

15.4

15.5

15.9

16.4

16.5

17.2

 

 

 

 

 

TC

 

212

217

226

244

266

285

306

222

225

231

250

272

291

312

 

 

 

 

85

SHC

 

212

194

185

159

133

109

87

222

211

198

170

140

113

88

 

 

 

 

 

kW

 

16.9

17.2

17.3

17.6

18.0

18.4

18.8

17.1

17.3

17.3

17.7

18.2

18.6

19.0

 

 

 

 

 

TC

 

206

208

217

236

257

276

295

215

216

223

241

262

281

301

 

 

 

 

95

SHC

 

206

197

181

156

129

106

84

215

213

194

166

136

110

84

 

 

 

 

 

kW

 

18.9

18.8

19.0

19.5

20.0

20.4

20.8

19.0

19.0

19.2

19.6

20.1

20.5

21.0

 

 

 

 

 

TC

 

199

202

209

227

247

265

285

208

209

215

232

252

270

 

 

 

 

105

SHC

 

199

190

177

152

126

103

80

208

209

189

163

132

107

 

 

 

 

 

kW

 

20.8

20.9

21.1

21.6

22.0

22.5

22.9

21.0

21.0

21.2

21.7

22.2

22.6

 

 

 

 

 

TC

 

192

194

200

218

237

254

202

202

207

222

242

259

 

 

 

 

115

SHC

 

192

192

173

149

122

99

202

202

183

159

129

103

 

 

 

 

 

kW

 

23.0

22.9

23.3

23.8

24.3

24.8

23.2

23.2

23.5

23.9

24.5

24.9

 

 

 

 

 

TC

 

191

191

199

216

235

252

200

200

205

220

240

257

 

 

 

 

117

SHC

 

191

191

172

148

121

99

200

200

182

158

128

102

 

 

 

 

 

kW

 

23.5

23.5

23.7

24.2

24.8

25.2

23.8

23.8

23.9

24.4

24.9

25.3

 

 

 

 

 

TC

 

189

189

196

213

232

249

197

198

203

217

236

 

 

 

 

120

SHC

 

189

189

170

147

120

98

197

198

181

156

127

 

 

 

 

 

kW

 

24.2

24.2

24.4

25.0

25.5

25.9

24.5

24.5

24.6

25.1

25.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

579F240 (20 Tons) (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

Evaporator Air Quantity — Cfm

 

 

 

 

 

 

 

 

 

Air Entering

 

 

 

 

8,000

 

 

 

 

 

 

9,000

 

 

 

 

300-

 

 

Condenser

 

 

 

 

 

 

Evaporator Air — Ewb (F)/BF

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54/0.58

58/0.43

62/0.30

67/0.23

72/0.21

76/0.22

80/0.04

54/0.62

58/0.48

62/0.35

67/0.24

72/0.23

76/0.23

80/0.04

 

 

 

 

 

 

 

 

579F180

 

 

75

TC

 

236

238

241

259

286

302

328

244

244

250

267

290

307

 

 

kW

 

17.5

17.3

17.4

17.8

18.3

18.7

17.5

17.6

17.6

18.0

18.4

18.8

 

 

 

 

SHC

 

236

232

211

181

149

119

91

244

244

222

192

155

123

 

 

 

 

 

kW

 

15.5

15.5

15.6

15.9

16.5

16.6

17.3

15.7

15.7

15.8

16.1

16.6

16.7

 

 

 

 

 

TC

 

231

230

237

254

276

296

237

238

243

258

281

300

 

 

 

 

85

SHC

 

231

230

209

179

146

117

237

238

216

189

152

121

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

223

223

229

245

267

285

231

230

235

249

270

289

 

 

 

 

95

SHC

 

223

223

203

176

142

114

231

230

209

185

148

117

 

 

 

 

 

kW

 

19.2

19.2

19.3

19.8

20.2

20.6

19.5

19.4

19.5

19.8

20.3

20.8

 

 

 

 

 

TC

 

216

216

221

236

256

274

222

223

228

239

260

278

 

 

 

 

105

SHC

 

216

216

197

172

139

110

222

223

202

181

145

114

 

 

 

 

 

kW

 

21.3

21.3

21.4

21.8

22.3

22.7

21.4

21.5

21.6

21.9

22.4

22.8

 

 

 

 

 

TC

 

208

209

213

226

246

263

214

214

220

229

249

266

 

 

 

 

115

SHC

 

208

209

190

168

135

107

214

214

193

177

141

110

 

 

 

 

 

kW

 

23.5

23.5

23.7

24.0

24.6

25.0

23.7

23.7

23.9

24.2

24.7

25.1

 

 

 

 

 

TC

 

207

207

212

224

243

260

213

213

219

227

246

263

 

 

 

 

117

SHC

 

207

207

188

167

134

106

213

213

191

176

140

109

 

 

 

 

 

kW

 

24.0

24.0

24.1

24.5

25.0

25.5

24.2

24.2

24.2

24.6

25.1

25.6

 

 

 

 

 

TC

 

204

205

209

221

240

210

210

215

224

243

 

 

 

 

120

SHC

 

204

205

185

166

133

210

210

193

175

139

 

 

 

 

 

kW

 

24.7

24.7

24.8

25.2

25.7

24.9

24.9

25.0

25.3

25.8

 

 

LEGEND

BF

Bypass Factor

Edb

Entering Dry-Bulb

Ewb

Entering Wet-Bulb

kW

Compressor Motor Power Input

ldb

Leaving Dry-Bulb

lwb

Leaving Wet-Bulb

SHC

Sensible Heat Capacity (1000 Btuh) Gross

TC

Total Capacity (1000 Btuh) Gross

NOTES:

1.Direct interpolation is permissible. Do not extrapolate.

2.The following formulas may be used:

tldb =

tedb

 

sensible capacity (Btuh)

 

 

1.10 x cfm

 

 

 

tlwb =

Wet-bulb temperature corresponding to enthalpy of air

leaving evaporator coil (hlwb)

 

hlwb =

hewb

total capacity (Btuh)

 

4.5 x cfm

 

 

 

Where: hewb = Enthalpy of air entering evaporator coil

3.The SHC is based on 80 F edb temperature of air entering evaporator coil. Below 80 F edb, subtract (corr factor x cfm) from SHC.

Above 80 F edb, add (corr factor x cfm) to SHC.

BYPASS

 

ENTERING AIR DRY-BULB TEMP (F)

79

78

77

76

75

under 75

FACTOR

81

82

83

84

85

over 85

(BF)

 

 

 

Correction Factor

 

0.05

1.04

2.07

3.11

4.14

5.18

 

0.10

0.98

1.96

2.94

3.92

4.91

 

0.20

0.87

1.74

2.62

3.49

4.36

 

0.30

0.76

1.53

2.29

3.05

3.82

Use formula

0.40

0.65

1.31

1.96

2.62

3.27

shown below.

0.50

0.55

1.09

1.64

2.18

2.73

 

0.60

0.44

0.87

1.31

1.74

2.18

 

0.70

0.33

0.65

0.98

1.31

1.64

 

Interpolation is permissible.

Correction Factor = 1.10 x (1 – BF) x (edb – 80).

156

Page 156
Image 156
Bryant 581A/B manual 156

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.