Bryant 581A/B manual Cooling CAPACITIES, Units with HOT GAS Reheat Option

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 213
Image 213

PERFORMANCE DATA (cont)

COOLING CAPACITIES, UNITS WITH HOT GAS REHEAT OPTION

581A181 (15 TONS) UNIT WITH HOT GAS REHEAT IN COOLING MODE

Temp (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Entering Evaporator — Cfm/BF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Entering

 

 

 

4500/0.02

 

 

 

 

5250/0.03

 

 

 

 

 

6000/0.04

 

 

 

 

 

6750/0.04

 

 

 

 

7500/0.05

 

 

Condenser

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Entering Evaporator — Ewb (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

 

62

 

67

72

57

 

62

 

67

72

 

57

 

62

67

 

72

57

 

62

 

67

 

72

57

62

 

67

 

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

TC

 

166

 

179

 

193

214

175

 

186

202

221

 

183

 

191

208

 

227

190

 

195

 

212

 

232

197

199

 

216

236

 

SHC

 

165

 

152

 

129

108

175

 

166

140

115

 

183

 

178

150

 

121

190

 

189

 

159

 

127

197

196

 

168

133

 

 

kW

 

10.4

 

10.6

10.7

10.9

10.5

 

10.6

10.8

11.0

 

10.6

 

10.7

10.9

 

11.1

10.7

 

10.7

 

10.9

 

11.2

10.8

10.8

 

11.0

11.2

85

 

TC

 

162

 

174

 

189

209

171

 

180

195

216

 

179

 

185

200

 

222

186

 

189

 

205

 

226

192

194

 

208

230

 

SHC

 

162

 

150

 

127

106

171

 

163

137

113

 

179

 

175

147

 

119

186

 

185

 

156

 

125

192

192

 

164

131

 

 

kW

 

11.7

 

11.9

12.1

12.3

11.8

 

12.0

12.1

12.4

 

11.9

 

12.0

12.2

 

12.5

12.0

 

12.1

 

12.3

 

12.5

12.1

12.1

 

12.3

12.6

95

 

TC

 

158

 

169

 

182

202

166

 

174

187

209

 

174

 

179

194

 

214

181

 

183

 

198

 

218

187

188

 

201

221

 

SHC

 

158

 

148

 

126

104

166

 

160

134

110

 

174

 

172

145

 

116

181

 

180

 

154

 

122

187

187

 

163

128

 

 

kW

 

12.7

 

12.9

13.1

13.3

12.9

 

13.0

13.2

13.4

 

13.0

 

13.0

13.2

 

13.5

13.1

 

13.1

 

13.3

 

13.6

13.1

13.2

 

13.4

13.6

105

 

TC

 

153

 

163

 

178

195

162

 

168

181

201

 

169

 

172

188

 

206

175

 

177

 

191

 

209

181

181

 

194

213

 

SHC

 

153

 

145

 

123

101

162

 

157

133

107

 

169

 

167

142

 

113

175

 

175

 

151

 

119

181

181

 

160

125

 

 

kW

 

14.1

 

14.2

14.4

14.7

14.2

 

14.3

14.5

14.8

 

14.3

 

14.3

14.6

 

14.8

14.4

 

14.4

 

14.6

 

14.9

14.5

14.5

 

14.7

14.9

115

 

TC

 

148

 

156

 

171

188

157

 

161

176

193

 

163

 

165

180

 

197

169

 

170

 

183

 

201

174

175

 

185

203

 

SHC

 

148

 

141

 

120

98

157

 

153

130

104

 

163

 

162

139

 

110

169

 

169

 

148

 

116

174

174

 

156

122

 

 

kW

 

15.5

 

15.6

15.8

16.1

15.6

 

15.7

15.9

16.2

 

15.7

 

15.8

16.0

 

16.3

15.8

 

15.8

 

16.1

 

16.3

15.9

15.9

 

16.1

16.4

125

 

TC

 

143

 

149

 

163

179

151

 

153

168

184

 

157

 

158

171

 

188

163

 

163

 

174

 

190

167

167

 

176

192

 

SHC

 

143

 

138

 

117

95

151

 

149

126

101

 

157

 

156

136

 

107

163

 

163

 

144

 

112

167

167

 

153

118

 

 

kW

 

17.0

 

17.1

17.4

17.7

17.2

 

17.2

17.5

17.8

 

17.3

 

17.3

17.6

 

17.8

17.4

 

17.4

 

17.6

 

17.9

17.5

17.5

 

17.6

17.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581A181 (15 TONS) UNIT WITH HOT GAS REHEAT — A IN REHEAT, B AND C OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator Air Quantity — Cfm/BF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Entering

 

 

4500/0.12

 

 

 

 

5250/0.14

 

 

 

 

 

6000/.015

 

 

 

 

 

6750/0.18

 

 

 

 

7500/0.18

 

 

Condenser

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator Air — Relative Humidity (%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

55

60

 

50

 

 

55

60

 

 

50

 

 

55

 

60

 

50

 

 

 

55

 

60

 

50

 

 

55

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

 

55

 

57

59

 

56

 

 

58

59

 

 

56

 

 

58

 

60

 

57

 

 

 

59

 

60

 

57

 

 

59

 

61

65

 

SHC

 

 

34

 

32

30

 

36

 

 

34

32

 

37

 

 

35

 

33

 

38

 

 

 

36

 

35

 

40

 

 

38

 

36

 

 

kW

 

 

4.4

 

4.5

4.5

 

4.4

 

 

4.5

4.5

 

4.4

 

 

4.5

 

4.5

 

4.4

 

 

4.5

 

4.5

 

4.4

 

 

4.5

 

4.5

 

 

TC

 

 

42

 

44

45

 

43

 

 

44

46

 

 

43

 

 

45

 

46

 

43

 

 

 

45

 

46

 

44

 

 

45

 

47

75

 

SHC

 

 

22

 

19

17

 

23

 

 

21

18

 

25

 

 

22

 

20

 

26

 

 

 

24

 

21

 

28

 

 

25

 

23

 

 

kW

 

 

4.8

 

4.8

4.8

 

4.8

 

 

4.8

4.8

 

4.8

 

 

4.8

 

4.8

 

4.8

 

 

4.8

 

4.8

 

4.8

 

 

4.8

 

4.8

 

 

TC

 

 

29

 

30

31

 

29

 

 

31

32

 

 

30

 

 

31

 

32

 

30

 

 

 

32

 

33

 

31

 

 

32

 

33

85

 

SHC

 

 

9

 

6

3

 

11

 

 

8

5

 

13

 

 

10

 

7

 

14

 

 

 

11

 

8

 

16

 

 

12

 

9

 

 

kW

 

 

5.2

 

5.2

5.3

 

5.2

 

 

5.2

5.3

 

5.2

 

 

5.2

 

5.3

 

5.2

 

 

5.2

 

5.3

 

5.2

 

 

5.2

 

5.3

 

 

TC

 

 

15

 

16

17

 

16

 

 

17

18

 

 

16

 

 

18

 

18

 

17

 

 

 

18

 

19

 

17

 

 

18

 

19

95

 

SHC

 

 

–3

 

–7

–11

 

–1

 

 

–5

–9

 

1

 

 

 

–3

 

–7

 

2

 

 

 

–2

 

–5

 

4

 

 

0

 

–4

 

 

kW

 

 

5.6

 

5.6

5.6

 

5.6

 

 

5.6

5.6

 

5.6

 

 

5.6

 

5.6

 

5.6

 

 

5.6

 

5.6

 

5.6

 

 

5.6

 

5.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581A181 (15 TONS) UNIT WITH HOT GAS REHEAT — A AND B IN REHEAT, C OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator Air Quantity — Cfm/BF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Entering

 

 

4500/0.12

 

 

 

 

5250/0.14

 

 

 

 

 

6000/.015

 

 

 

 

 

6750/0.18

 

 

 

 

7500/0.18

 

 

Condenser

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator Air — Relative Humidity (%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

55

60

 

50

 

 

55

60

 

 

50

 

 

55

 

60

 

50

 

 

 

55

 

60

 

50

 

 

55

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

 

81

 

84

86

 

82

 

 

85

87

 

 

83

 

 

86

 

88

 

84

 

 

 

87

 

89

 

85

 

 

87

 

90

65

 

SHC

 

 

34

 

32

30

 

36

 

 

33

31

 

37

 

 

35

 

33

 

39

 

 

 

36

 

34

 

40

 

 

38

 

36

 

 

kW

 

 

7.8

 

7.9

7.9

 

7.8

 

 

7.9

7.9

 

7.8

 

 

7.9

 

7.9

 

7.8

 

 

7.9

 

7.9

 

7.8

 

 

7.9

 

7.9

 

 

TC

 

 

62

 

64

66

 

62

 

 

65

67

 

 

63

 

 

66

 

68

 

64

 

 

 

66

 

68

 

64

 

 

67

 

69

75

 

SHC

 

 

22

 

19

16

 

24

 

 

21

18

 

25

 

 

22

 

20

 

27

 

 

 

24

 

21

 

28

 

 

25

 

22

 

 

kW

 

 

8.5

 

8.5

8.5

 

8.5

 

 

8.5

8.5

 

8.5

 

 

8.5

 

8.5

 

8.5

 

 

8.5

 

8.5

 

8.5

 

 

8.5

 

8.5

 

 

TC

 

 

42

 

44

46

 

43

 

 

45

46

 

 

43

 

 

45

 

47

 

44

 

 

 

46

 

48

 

44

 

 

46

 

48

85

 

SHC

 

 

10

 

6

2

 

12

 

 

8

4

 

14

 

 

10

 

6

 

15

 

 

 

11

 

8

 

16

 

 

13

 

9

 

 

kW

 

 

9.2

 

9.2

9.3

 

9.2

 

 

9.2

9.3

 

9.2

 

 

9.2

 

9.3

 

9.2

 

 

9.2

 

9.3

 

9.2

 

 

9.2

 

9.3

 

 

TC

 

 

23

 

24

26

 

23

 

 

25

26

 

 

24

 

 

25

 

27

 

24

 

 

 

26

 

27

 

24

 

 

26

 

27

95

 

SHC

 

 

–2

 

–7

–11

 

0

 

 

–5

–9

 

2

 

 

 

–3

 

–7

 

3

 

 

 

–1

 

–6

 

5

 

 

0

 

–4

 

 

kW

 

 

9.9

 

9.9

9.9

 

9.9

 

 

9.9

9.9

 

9.9

 

 

9.9

 

9.9

 

9.9

 

 

9.9

 

9.9

 

9.9

 

 

9.9

 

9.9

 

 

LEGEND

BF

Bypass Factor

Edb

Entering Dry-Bulb

Ewb —

Entering Wet-Bulb

kW

Compressor Motor Power Input

ldb

Leaving Dry-Bulb

lwb

Leaving Wet-Bulb

SHC —

Sensible Heat Capacity (1000 Btuh) Gross

TC

Total Capacity (1000 Btuh) Gross

NOTES:

1.Direct interpolation is permissible. Do not extrapolate.

2.The following formulas may be used:

sensible capacity (Btuh)

tldb = tedb 1.10 x cfm

tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving evapo- rator coil (hlwb)

3.The SHC is based on 80 F edb temperature of air entering evaporator coil. Below 80 F edb, subtract (corr factor x cfm) from SHC.

Above 80 F edb, add (corr factor x cfm) to SHC.

 

 

 

Correction Factor

 

 

581A155

BYPASS

 

ENTERING AIR DRY-BULB TEMP (F)

 

 

FACTOR

79

78

77

76

75

under 75

 

(BF)

81

82

83

84

85

over 85

 

 

 

 

 

 

 

 

-300

.05

1.04

2.07

3.11

4.14

5.18

Use for-

.10

.98

1.96

2.94

3.92

4.90

mula

.20

.87

1.74

2.62

3.49

4.36

shown

 

.30

.76

1.53

2.29

3.05

3.82

below.

 

Interpolation is permissible.

Correction Factor = 1.10 x (1 – BF) x (edb – 80).

total capacity (Btuh)

hlwb = hewb 4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil

213

Page 213
Image 213
Bryant 581A/B manual Cooling CAPACITIES, Units with HOT GAS Reheat Option

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.