PERFORMANCE DATA (cont)

FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS

581B036 (3 TONS) — STANDARD MOTOR (BELT DRIVE)*

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

900

553

0.14

134

681

0.22

221

782

0.32

316

870

0.42

417

948

0.53

526

 

 

 

1000

582

0.16

163

707

0.26

257

807

0.36

358

894

0.47

466

971

0.58

580

 

 

 

1100

612

0.20

196

734

0.30

297

833

0.41

405

919

0.52

519

995

0.64

639

 

 

 

1200

643

0.23

234

762

0.34

343

859

0.46

458

944

0.58

579

1020

0.71

705

 

 

 

1300

675

0.28

277

790

0.40

394

886

0.52

517

969

0.65

644

1044

0.78

777

 

 

 

1400

707

0.33

326

819

0.45

452

913

0.58

581

996

0.72

716

1070

0.86

855

 

 

 

1500

740

0.38

382

849

0.52

515

941

0.66

653

1023

0.80

795

1096

0.95

941

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581B036 (3 TONS) — STANDARD MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

 

581B036

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

900

1019

0.64

640

1084

0.76

760

1146

0.89

885

1203

1.02

1016

1258

1.16

1152

 

-150

 

1000

1042

0.70

700

1107

0.83

825

1168

0.96

956

1225

1.10

1091

 

 

1100

1065

0.77

765

1130

0.90

896

1190

1.04

1032

1247

1.18

1173

 

 

1200

1089

0.84

837

1153

0.98

974

1213

1.12

1115

 

 

 

1300

1113

0.92

915

1177

1.06

1058

 

 

 

1400

1138

1.01

1000

1201

1.15

1149

 

 

 

1500

1163

1.10

1092

 

 

 

LEGEND

Bhp — Brake Horsepower

Watts — Input Watts to Motor

*Motor drive range: 680 to 1044 rpm. All other rpms require field- supplied drive.

See page 103 for general fan performance notes.

NOTES:

1.Boldface indicates field-supplied drive is required.

2.Maximum continuous bhp is 1.20.

581B036 (3 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)*

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

900

553

0.14

134

681

0.22

221

 

782

0.32

316

870

0.42

417

948

0.53

526

1000

582

0.16

163

707

0.26

257

 

807

0.36

358

894

0.47

466

971

0.58

580

1100

612

0.20

196

734

0.30

297

 

833

0.41

405

919

0.52

519

995

0.64

639

1200

643

0.23

234

762

0.34

343

 

859

0.46

458

944

0.58

579

1020

0.71

705

1300

675

0.28

277

790

0.40

394

 

886

0.52

517

969

0.65

644

1044

0.78

777

1400

707

0.33

326

819

0.45

452

 

913

0.58

581

996

0.72

716

1070

0.86

855

1500

740

0.38

382

849

0.52

515

 

941

0.66

653

1023

0.80

795

1096

0.95

941

 

 

 

 

 

 

 

 

 

 

581B036 (3 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

900

1019

0.64

640

1084

0.76

760

 

1146

0.89

885

1203

1.02

1016

1258

1.16

1152

1000

1042

0.70

700

1107

0.83

825

 

1168

0.96

956

1225

1.10

1091

1279

1.24

1232

1100

1065

0.77

765

1130

0.90

896

 

1190

1.04

1032

1247

1.18

1173

1301

1.33

1319

1200

1089

0.84

837

1153

0.98

974

 

1213

1.12

1115

1270

1.27

1262

1324

1.42

1413

1300

1113

0.92

915

1177

1.06

1058

 

1237

1.21

1205

1293

1.36

1358

1347

1.52

1514

1400

1138

1.01

1000

1201

1.15

1149

 

1261

1.31

1303

1317

1.47

1461

1370

1.63

1623

1500

1163

1.10

1092

1226

1.25

1247

 

1285

1.41

1407

1341

1.58

1571

1394

1.75

1740

LEGEND

Bhp — Brake Horsepower

Watts — Input Watts to Motor

*Motor drive range: 1075 to 1455 rpm. All other rpms require field- supplied drive.

See page 103 for general fan performance notes.

NOTES:

1.Boldface indicates field-supplied drive is required.

2.Maximum continuous bhp is 2.40.

115

Page 115
Image 115
Bryant 581A/B manual 581B036 3 Tons HIGH-STATIC Motor Belt Drive

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.