Bryant 581A/B ARI* Capacity Ratings 581A155,180, Heating Capacities and Efficiencies 581A155-180

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 14
Image 14

ARI* CAPACITY RATINGS — 581A155,180

LOW HEAT UNITS

UNIT

NOMINAL

NET COOLING

 

TOTAL

 

SOUND

 

CAPACITY

 

EER

RATING

IPLV

581A

TONS

 

WATTS

(Btuh)

 

 

(dB)

 

 

 

 

 

 

 

155230

13

134,000

 

12,209

10.60

88

11.4

180275

15

180,000

 

17,064

10.50

88

11.4

 

 

 

HIGH HEAT UNITS

 

 

 

 

 

 

 

 

 

 

 

UNIT

NOMINAL

NET COOLING

 

TOTAL

 

SOUND

 

CAPACITY

 

EER

RATING

IPLV

581A

TONS

 

WATTS

(Btuh)

 

 

(dB)

 

 

 

 

 

 

 

155300

13

134,000

 

12,218

10.60

88

11.4

180360

15

180,000

 

17,179

10.50

88

11.1

 

LEGEND

dB

Sound Levels (decibels)

db

Dry Bulb

EER — Energy Efficiency Ratio

IPLV

Integrated Part-Load Values

wb

Wet Bulb

*Air Conditioning and Refrigeration Institute.

NOTES:

1.Rated in accordance with ARI Standards 360 and 270.

2.ARI ratings are net values, reflecting the effects of circulating fan heat.

3.Ratings are based on:

Cooling Standard: 80 F db, 67 F wb indoor entering-air tempera- ture and 95 F db air entering outdoor unit.

IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F db outdoor entering-air temperature.

4.All 581A155, 180 units are in compliance with ASHRAE 90.1- 1999 Energy Standard for minimum EER requirements. Refer to state and local codes or visit the following website: http://sol- stice.crest.org/efficiency/bcap to determine if compliance with this standard pertains to a given geographical area of the United States.

HEATING CAPACITIES AND EFFICIENCIES — 581A155-180

 

HEATING

OUTPUT

TEMPERATURE

AGA STEADY

MINIMUM HEATING

UNIT 581A

INPUT (Btuh)

CAPACITY

STATE

RISE (F)

CFM†

 

Stage 2/Stage 1*

(Btuh)

EFFICIENCY (%)

 

 

 

155230

230,000/172,000

186,000

15-45

81.0

3750

155300

300,000/225,000

243,000

30-60

81.0

3830

180275

275,000/206,000

223,000

15-45

81.0

4580

180360

360,000/270,000

292,000

20-50

81.0

5400

*All units are 2-stage heat.

†Minimum heating cfm must be maintained to ensure proper heating operation.

NOTE: Minimum allowable temperature of mixed air entering the heat exchanger during first stage heating is 45 F. There is no minimum mixed-air limitation during second-stage heating. For entering air temperatures below 45 F, both stages of heat must be energized together to minimize conden- sation issues and ensure proper unit operation.

LOW OUTDOOR AIR TEMPERATURE

COOLING OPERATION LIMITS

 

 

TEMPERATURE LIMIT (F)

UNIT SIZE

Standard

Unit With

Unit With

581A

Motormaster®

Unit

Low Ambient Kit

 

Control

 

 

 

155, 180

40

20

–20

AIR QUANTITY LIMITS (Cooling)

UNIT 581A

MINIMUM CFM

MAXIMUM CFM

155

3900

6500

180

4500

7500

14