Bryant 581A/B manual 219

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 219
Image 219

PERFORMANCE DATA (cont)

FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)

581A155 (12 TONS) WITH STANDARD MOTOR (High Heat Units)*

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

0.6

 

 

 

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

Bhp

 

Rpm

Watts

 

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

3750

622

888

0.89

713

1027

1.13

 

795

1234

 

 

1.37

869

1454

1.63

936

1584

1.89

4000

652

1015

1.04

738

1168

1.28

 

818

1388

 

 

1.54

890

1620

1.80

956

1756

2.07

4250

682

1151

1.20

763

1317

1.45

 

841

1550

 

 

1.72

911

1793

1.99

976

1937

2.27

4500

713

1295

1.38

790

1474

1.63

 

864

1719

 

 

1.91

934

1973

2.20

997

2126

2.49

4750

744

1448

1.58

817

1641

1.84

 

889

1896

 

 

2.12

956

2159

2.42

1019

2326

2.72

5000

776

1610

1.80

845

1817

2.06

 

914

2081

 

 

2.35

979

2353

2.66

1041

2536

2.97

5250

808

1783

2.04

874

2003

2.31

 

940

2277

 

 

2.60

1003

2556

2.91

1064

2757

3.24

5500

840

1967

2.29

903

2200

2.57

 

966

2482

 

 

2.87

1028

2768

3.19

 

 

 

1087

2991

3.52

5750

872

2163

2.57

933

2410

2.86

 

993

2699

 

 

3.16

 

 

 

1110

3237

3.83

1053

2990

3.49

6000

905

2373

2.87

963

2634

3.16

 

 

 

 

 

 

 

1078

3225

3.81

1134

3497

4.15

 

1021

2929

 

 

3.47

6250

937

2596

3.19

 

 

 

 

1049

3172

 

 

3.81

1105

3473

4.15

1159

3769

4.50

994

2872

3.49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581A155 (12 TONS) WITH STANDARD MOTOR (High Heat Units)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

 

1.6

 

 

 

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

Bhp

 

Rpm

Watts

 

Bhp

Rpm

Watts

Bhp

Rpm

Watts

Bhp

3750

999

1829

2.15

1059

2091

2.42

 

1117

2343

 

 

2.70

1174

2521

2.99

1228

2801

3.29

4000

1017

2010

2.35

1076

2279

2.63

 

1132

2540

 

 

2.91

1186

2738

3.21

 

 

 

 

1239

3023

3.51

4250

1036

2198

2.56

1093

2474

2.85

 

1148

2743

 

 

3.14

 

 

 

1253

3251

3.75

 

1201

2962

3.44

4500

1056

2395

2.78

1112

2675

3.08

 

 

 

 

 

 

 

1217

3194

3.70

1267

3487

4.01

 

1166

2951

 

 

3.39

4750

1077

2601

3.03

1132

2885

3.34

 

1184

3168

 

 

3.65

1235

3435

3.97

1284

3731

4.29

5000

1098

2816

3.29

 

 

 

 

1204

3392

 

 

3.93

1253

3683

4.26

1301

3981

4.59

1152

3104

3.61

 

 

 

5250

 

 

 

1173

3332

3.90

 

1224

3626

 

 

4.23

1273

3940

4.57

1320

4239

4.91

1120

3042

3.56

 

5500

1142

3279

3.86

1195

3570

4.20

 

1245

3870

 

 

4.55

1293

4203

4.89

1339

4501

5.24

5750

1165

3528

4.18

1217

3819

4.53

 

1266

4125

 

 

4.88

1313

4471

5.24

6000

1188

3789

4.51

1239

4080

4.88

 

1288

4389

 

 

5.24

6250

1212

4062

4.87

1262

4351

5.24

 

 

 

 

LEGEND

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

Bhp

Brake Horsepower

 

 

 

 

 

 

1.

 

 

 

Field-supplied motor required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watts

Input Watts to Motor

 

 

 

 

 

 

2. Maximum continuous bhp for the standard motor is 3.13 (for 208/230 and

*Standard low-medium static drive range is 895 to 1147 rpm. Other rpms require a

460-v units) or 3.38 (for 575-v units). The maximum continuous watts is

2700 (for 208/230 and 460-v units) or 3065 (for 575-v units). Do not adjust

field-supplied drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

motor rpm such that motor maximum bhp and/or watts is exceeded at the

Refer to page 230 for general Fan Performance Data notes.

 

 

 

 

 

 

maximum operating cfm. See Evaporator Fan Motor Data tables for more

information.

3. Fan performance is identical for horizontal discharge applications using Bryant horizontal adapter curb.

581A155 (12 TONS) WITH OPTIONAL MOTOR (High Heat Units)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

0.6

 

 

 

 

0.8

 

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

 

Bhp

Rpm

Watts

 

Bhp

Rpm

 

Watts

Bhp

Rpm

 

Watts

Bhp

3750

622

888

0.89

713

1027

 

1.13

795

1234

 

1.37

869

 

1454

1.63

936

 

1584

1.89

4000

652

1015

1.04

738

1168

 

1.28

818

1388

 

1.54

890

 

1620

1.80

956

 

1756

2.07

4250

682

1151

1.20

763

1317

 

1.45

841

1550

 

1.72

911

 

1793

1.99

976

 

1937

2.27

4500

713

1295

1.38

790

1474

 

1.63

864

1719

 

1.91

934

 

1973

2.20

997

 

2126

2.49

4750

744

1448

1.58

817

1641

 

1.84

889

1896

 

2.12

956

 

2159

2.42

1019

 

2326

2.72

5000

776

1610

1.80

845

1817

 

2.06

914

2081

 

2.35

979

 

2353

2.66

1041

 

2536

2.97

5250

808

1783

2.04

874

2003

 

2.31

940

2277

 

2.60

1003

 

2556

2.91

1064

 

2757

3.24

5500

840

1967

2.29

903

2200

 

2.57

966

2482

 

2.87

1028

 

2768

3.19

1087

 

2991

3.52

5750

872

2163

2.57

933

2410

 

2.86

993

2699

 

3.16

1053

 

2990

3.49

1110

 

3237

3.83

6000

905

2373

2.87

963

2634

 

3.16

1021

2929

 

3.47

1078

 

3225

3.81

1134

 

3497

4.15

6250

937

2596

3.19

994

2872

 

3.49

1049

3172

 

3.81

1105

 

3473

4.15

 

 

 

 

1159

 

3769

4.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581A155 (12 TONS) WITH OPTIONAL MOTOR (High Heat Units)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

Available External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

1.2

 

 

1.4

 

 

 

1.6

 

 

 

 

1.8

 

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

 

Bhp

Rpm

Watts

 

Bhp

Rpm

 

Watts

Bhp

Rpm

 

Watts

Bhp

3750

999

1829

2.15

1059

2091

 

2.42

1117

2343

 

2.70

1174

 

2521

2.99

1228

 

2801

3.29

4000

1017

2010

2.35

1076

2279

 

2.63

1132

2540

 

2.91

1186

 

2738

3.21

1239

 

3023

3.51

4250

1036

2198

2.56

1093

2474

 

2.85

1148

2743

 

3.14

1201

 

2962

3.44

1253

 

3251

3.75

4500

1056

2395

2.78

1112

2675

 

3.08

1166

2951

 

3.39

1217

 

3194

3.70

1267

 

3487

4.01

4750

1077

2601

3.03

1132

2885

 

3.34

1184

3168

 

3.65

1235

 

3435

3.97

1284

 

3731

4.29

5000

1098

2816

3.29

1152

3104

 

3.61

1204

3392

 

3.93

 

 

 

 

1301

 

3981

4.59

1253

 

3683

4.26

 

5250

1120

3042

3.56

1173

3332

 

3.90

1224

3626

 

4.23

1273

 

3940

4.57

1320

 

4239

4.91

5500

1142

3279

3.86

1195

3570

 

4.20

 

 

 

 

 

 

1293

 

4203

4.89

1339

 

4501

5.24

1245

3870

 

4.55

 

5750

1165

3528

4.18

1217

3819

 

4.53

1266

4125

 

4.88

1313

 

4471

5.24

 

6000

1188

3789

4.51

1239

4080

 

4.88

1288

4389

 

5.24

 

 

6250

1212

4062

4.87

1262

4351

 

5.24

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

Bhp

Brake Horsepower

 

 

 

 

 

 

1.

 

 

 

Field-supplied motor required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watts

Input Watts to Motor

 

 

 

 

 

 

2. Maximum continuous bhp for the optional motor is 4.26. The maximum contin-

*Alternate high-static drive range is 1040 to 1315. Other rpms require a field-

uous watts is 3610. Do not adjust motor rpm such that motor maximum bhp

and/or watts is exceeded at the maximum operating cfm. See Evaporator Fan

supplied drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor Data tables for more information.

 

 

 

 

Refer to page 230 for general Fan Performance Data notes.

 

 

 

 

 

 

 

 

3. Fan

performance is

identical for

horizontal

discharge

applications using

Bryant horizontal adapter curb.

581A155-300

219

Page 219
Image 219
Bryant 581A/B manual 219

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.