Bryant 581A/B manual 183

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 183
Image 183

PERFORMANCE DATA (cont)

COOLING CAPACITIES (cont)

580F240 (20 TONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Entering Evaporator — Cfm/BF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Entering

 

 

6,000/0.04

 

 

 

7,000/0.05

 

 

 

 

 

8,000/0.06

 

 

 

 

9,000/0.07

 

 

 

10,000/0.08

 

 

Condenser

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air

Entering Evaporator — Ewb

(F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

 

67

 

72

 

 

62

 

67

72

 

 

62

 

 

67

 

72

 

62

 

 

 

67

 

72

 

62

 

 

67

 

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

 

237

 

258

 

282

 

242

 

264

288

 

 

247

 

 

268

 

291

 

252

 

 

271

 

295

 

258

 

 

274

 

298

 

75

 

 

SHC

 

 

204

 

171

 

138

 

221

 

184

146

 

 

237

 

 

199

 

156

 

247

 

 

210

 

164

 

257

 

 

221

 

172

 

 

 

 

kW

 

16.7

 

17.4

 

18.1

 

16.9

 

17.6

18.3

 

 

17.1

 

 

17.8

 

18.5

 

17.3

 

 

17.9

 

18.6

 

17.5

 

18.0

 

18.7

 

 

 

 

TC

 

 

229

 

249

 

272

 

234

 

254

278

 

 

239

 

 

260

 

283

 

245

 

 

262

 

286

 

250

 

 

265

 

287

 

85

 

 

SHC

 

 

201

 

167

 

135

 

216

 

180

142

 

 

231

 

 

193

 

150

 

240

 

 

203

 

157

 

250

 

 

217

 

167

 

 

 

 

kW

 

18.1

 

18.7

 

19.5

 

18.3

 

18.9

19.7

 

 

18.5

 

 

19.1

 

19.9

 

18.7

 

 

19.3

 

20.1

 

18.8

 

19.4

 

20.1

 

 

 

 

TC

 

 

220

 

239

 

261

 

225

 

245

267

 

 

230

 

 

249

 

271

 

235

 

 

251

 

275

 

241

 

 

255

 

277

 

95

 

 

SHC

 

 

195

 

163

 

130

 

211

 

176

138

 

 

224

 

 

188

 

145

 

233

 

 

199

 

152

 

241

 

 

210

 

160

 

 

 

 

kW

 

19.4

 

20.2

 

20.9

 

19.7

 

20.4

21.2

 

 

19.9

 

 

20.6

 

21.3

 

20.1

 

 

20.6

 

21.4

 

20.3

 

20.8

 

21.6

 

 

 

 

TC

 

 

209

 

228

 

249

 

216

 

234

254

 

 

220

 

 

237

 

259

 

225

 

 

240

 

262

 

230

 

 

242

 

263

105

 

 

SHC

 

 

189

 

159

 

126

 

206

 

171

134

 

 

217

 

 

183

 

140

 

225

 

 

195

 

148

 

230

 

 

205

 

154

 

 

 

 

kW

 

20.9

 

21.5

 

22.3

 

21.2

 

21.8

22.5

 

 

21.4

 

 

22.0

 

22.7

 

21.6

 

 

22.1

 

22.9

 

21.8

 

22.2

 

23.0

 

 

 

 

TC

 

 

200

 

217

 

237

 

205

 

222

241

 

 

211

 

 

225

 

244

 

216

 

 

227

 

248

 

221

 

 

229

 

249

115

 

 

SHC

 

 

185

 

154

 

122

 

199

 

166

129

 

 

209

 

 

178

 

136

 

216

 

 

189

 

143

 

221

 

 

200

 

150

 

 

 

 

kW

 

22.5

 

23.1

 

23.8

 

22.7

 

23.3

24.0

 

 

22.9

 

 

23.4

 

24.2

 

23.2

 

 

23.6

 

24.4

 

23.4

 

23.7

 

24.4

 

 

 

 

TC

 

 

194

 

211

 

230

 

199

 

216

234

 

 

205

 

 

218

 

237

 

210

 

 

220

 

240

 

214

 

 

222

 

241

120

 

 

SHC

 

 

183

 

152

 

121

 

195

 

164

126

 

 

204

 

 

175

 

134

 

210

 

 

186

 

141

 

214

 

 

196

 

148

 

 

 

 

kW

 

23.2

 

23.8

 

24.6

 

23.5

 

24.0

 

23.7

 

 

24.2

 

23.9

 

 

24.4

 

24.1

 

24.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

580F300 (25 TONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Entering Evaporator — Cfm/BF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Entering

 

 

7,000/0.05

 

 

 

 

8,000/0.06

 

 

 

 

 

9,000/0.07

 

 

 

 

 

10,000/0.08

 

 

 

 

11,250/0.09

 

Condenser

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air

Entering Evaporator — Ewb

(F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

 

62

 

 

67

 

72

57

 

62

67

72

 

57

 

62

 

67

 

72

 

57

 

62

 

67

 

72

 

57

62

 

67

 

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

256

 

271

 

299

 

327

267

 

278

305

336

 

276

 

283

 

309

 

341

 

285

 

286

 

313

 

344

 

294

294

 

316

347

75

 

 

SHC

256

 

232

 

196

 

159

267

 

249

208

166

 

276

 

265

 

220

 

173

 

285

 

281

 

232

 

182

 

294

294

 

252

198

 

 

 

 

kW

18.0

 

18.3

 

18.9

19.6

18.3

 

18.5

19.1

19.8

 

18.5

 

18.7

 

19.2

 

19.9

 

18.7

 

18.8

 

19.4

 

20.1

 

19.0

19.0

 

19.5

20.2

 

 

 

 

TC

248

 

262

 

288

 

316

259

 

267

293

322

 

267

 

273

 

298

 

328

 

276

 

276

 

302

 

331

 

284

285

 

305

336

85

 

 

SHC

248

 

228

 

192

 

154

259

 

244

204

161

 

267

 

259

 

216

 

169

 

276

 

274

 

228

 

175

 

284

284

 

244

187

 

 

 

 

kW

20.0

 

20.4

 

20.9

21.5

20.3

 

20.4

21

21.7

 

20.6

 

20.6

 

21.2

 

21.9

 

20.8

 

20.8

 

21.3

 

22

 

21

21

 

21.5

22.1

 

 

 

 

TC

241

 

252

 

277

 

303

251

 

257

281

309

 

259

 

262

 

286

 

314

 

266

 

267

 

290

 

317

 

274

275

 

293

321

95

 

 

SHC

241

 

223

 

187

 

149

251

 

239

198

157

 

259

 

254

 

210

 

164

 

266

 

265

 

222

 

171

 

274

275

 

238

180

 

 

 

 

kW

22.4

 

22.6

 

23.1

23.7

22.6

 

22.7

23.3

23.9

 

22.8

 

22.9

 

23.4

 

24

 

23

 

23

 

23.5

 

24.2

 

23.2

23.2

 

23.6

24.2

 

 

 

 

TC

233

 

243

 

266

 

289

242

 

247

270

295

 

250

 

252

 

273

 

299

 

256

 

258

 

277

 

303

 

264

265

 

280

306

105

 

 

SHC

233

 

218

 

182

 

145

242

 

233

194

152

 

250

 

248

 

206

 

159

 

256

 

257

 

217

 

166

 

264

265

 

232

176

 

 

 

 

kW

24.9

 

25.1

 

25.6

26.2

25.2

 

25.3

25.8

26.3

 

25.4

 

25.4

 

25.9

 

26.5

 

25.6

 

25.6

 

26

 

26.6

 

25.8

25.8

 

26.1

26.7

 

 

 

 

TC

225

 

232

 

254

 

277

234

 

236

258

281

 

241

 

242

 

261

 

285

 

247

 

247

 

264

 

288

 

254

255

 

267

291

115

 

 

SHC

225

 

214

 

178

 

140

234

 

228

189

148

 

241

 

241

 

201

 

155

 

247

 

247

 

211

 

162

 

253

255

 

227

171

 

 

 

 

kW

27.9

 

27.9

 

28.5

29

28

 

28.1

28.6

29.2

 

28.2

 

28.2

 

28.7

 

29.2

 

28.4

 

28.4

 

28.8

 

29.3

 

28.7

28.7

 

28.9

29.5

 

 

 

 

TC

216

 

221

 

241

 

263

224

 

225

245

267

 

231

 

231

 

248

 

269

 

237

 

236

 

251

 

273

 

243

242

 

253

276

125

 

 

SHC

216

 

208

 

173

 

136

223

 

221

184

142

 

230

 

231

 

196

 

149

 

236

 

236

 

206

 

157

 

243

242

 

221

166

 

 

 

 

kW

30.9

 

31.1

 

31.6

32

31.2

 

31.2

31.7

32.2

 

31.4

 

31.4

 

31.7

 

32.3

 

31.6

 

31.6

 

31.9

 

32.3

 

31.7

31.7

 

31.9

32.5

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BF

Bypass Factor

 

 

 

kW

Compressor Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Edb

Entering Dry Bulb

SHC

Gross Sensible Capacity (1000 Btuh)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ewb

Entering Wet Bulb

TC

Gross Cooling Capacity (1000 Btuh)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

580F180-300

183

Page 183
Image 183
Bryant 581A/B manual 183

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.