Bryant 581A/B Model Number Nomenclature 581A155, 180, 181 13 to 15 Tons, 581A E 180 230 - C B

Models: 581A/B

1 268
Download 268 pages 21.01 Kb
Page 7
Image 7

MODEL NUMBER NOMENCLATURE 581A155, 180, 181 — 13 to 15 Tons

581A E

V 180 230 – – C B

 

581A – Single Package

Fan Drive Position

 

High Efficiency Gas/Electric Unit

(Standard Motor)

 

 

B – Standard Low-Medium

 

 

Fan Drive Static

 

 

Capability

 

Voltage Designation

D – Alternate High Fan

 

Drive Static Capability

 

E – 460-3-60

 

 

 

P – 208/230-3-60

 

 

T – 575-3-60

Factory-Installed Outdoor-Air

 

 

and Other Upgrade Options

 

C – EconoMi$er IV

 

 

H – Manual Outdoor-Air Damper

Fuel and Control Type

 

 

V – Natural Gas/Electric Relight Pilot

Design Series Change

 

 

 

 

Gas Heat Input (Btuh)

 

Nominal Tons

230 – 230,000

 

275 – 275,000

a48-8194

155 – 13 Tons

300 – 300,000

180 – 15 Tons

360 – 360,000

 

181 – 15 Tons with hot gas reheat*

 

 

*See pages 213 and 214 for cooling capacity tables for 5581A181 unit. For all other data, contact application engineering.

NOTE: All indoor-fan motors 5 hp and larger meet the minimum efficiency requirements as established by the Energy Policy Act of 1992 (EPACT) effective October 24, 1997.

The example model number: 581AEV180230--CB designates a 15 ton 460-3-60 high efficiency gas/electric rooftop unit with 230,000 Btuh natural gas input, EconoMi$er IV and standard, low-medium fan drive static capability.

MODEL NUMBER NOMENCLATURE

581A210-300 — 18 to 25 Tons

5

8 1

A E A 2 1

0 2 5 0 – – A

A

 

 

 

 

 

 

 

Factory-Installed

581A – High Efficiency Rooftop

 

 

 

 

 

Options*

 

 

 

 

 

 

Units Gas Heating/

 

 

 

 

 

 

Electric Cooling

 

 

 

 

 

 

Constant Volume

 

 

 

 

 

 

Voltage Designation

 

 

 

 

Coil Protection Options*

 

 

 

 

 

 

 

E – 460-3-60

 

 

 

 

 

 

 

P – 208/230-3-60

 

 

 

 

 

 

 

T – 575-3-60

 

 

 

 

 

 

 

Indoor Fan, Orientation, Hinged Doors

Design Series Code

Return/Supply Smoke Detector Options*

 

 

 

 

 

 

Nominal Cooling Capacity

 

 

 

 

 

 

210 – 18 Tons

 

 

 

 

 

 

a48-8208

240 – 20 Tons

 

 

 

 

 

 

300 – 25 Tons

 

 

 

 

 

 

 

Gas Heat Input (Btuh)

 

 

 

 

 

 

250 – 250,000

25S-- 250,000 w/SS Heat Exchanger

 

 

 

 

 

 

365 – 365,000

36S-- 365,000 w/SS Heat Exchanger

 

 

 

 

 

 

400 – 400,000

40S-- 400,000 w/SS Heat Exchanger

 

 

 

 

 

 

SS — Stainless Steel *Refer to unit price pages.

7

Page 7
Image 7
Bryant 581A/B Model Number Nomenclature 581A155, 180, 181 13 to 15 Tons, 581A210-300 18 to 25 Tons, 581A E 180 230 - C B

581A/B specifications

The Bryant 581A/B is a sophisticated rooftop unit designed for commercial heating and cooling applications, striking a balance between performance, efficiency, and versatility. This unit is engineered to cater to various building sizes and configurations, making it an excellent choice for businesses seeking reliable climate control solutions.

One of the standout features of the Bryant 581A/B is its high efficiency. With SEER ratings reaching up to 14.5, this unit can significantly reduce energy costs while providing optimal performance throughout its operational lifespan. The design incorporates advanced compressor technology, allowing for variable speed operation that not only enhances comfort but also promotes energy savings by adjusting to the real-time demands of the environment.

The Bryant 581A/B also integrates cutting-edge refrigerant technology. Utilizing Puron refrigerant, it adheres to current environmental standards, minimizing its impact on ozone depletion while maximizing cooling performance. This commitment to sustainability is complemented by energy-efficient components, including high-efficiency coils and fan motors, which further optimize energy consumption.

In terms of construction, the Bryant 581A/B is built to withstand the rigors of outdoor installation. The unit features a rugged cabinet design with durable, corrosion-resistant materials, ensuring long-term reliability even in challenging weather conditions. Additionally, the easily accessible components simplify maintenance, reducing downtime for businesses.

The functionality of the Bryant 581A/B extends beyond mere cooling and heating. It is equipped with advanced control systems that can be interfaced with building management systems, allowing for seamless integration and enhanced control over indoor climate. This technology provides operators with the ability to monitor and adjust settings remotely, ensuring a comfortable indoor environment while optimizing energy use.

Noise reduction is another important characteristic of the Bryant 581A/B. The unit is designed with sound-dampening features, making it suitable for applications where low noise levels are a priority, such as retail spaces or office buildings.

Overall, the Bryant 581A/B is a robust solution for businesses seeking efficient, reliable, and flexible climate control. Its combination of advanced technology, durable construction, and user-friendly features make it a leading choice in the commercial HVAC market.