POTS

3M™ Dynatel™ Advanced Modular System 965AMS

Measurement Functions

POTS

Tests available with the POTS key POTS>LossPOTS>Loss>Hook-Up include Loss, Noise, Longitudinal Balance, Load Coil Counter, Caller ID, Ringers, Level Trace, Kick Test and Voice Band Spectrum Analyzer.

POTS>Loss

Use Loss to measure the loss from the far-end of a circuit to the near-end using a precision tone between 200 Hz and 20kHz.

Note: You must use a device at the far end to generate the tone. This could be the milliwatt number in the central office or a 965AMS set to the tone mode.

POTS>Loss>Hook-Up

RED

Ring (B)

GRN

Ground (Earth)

BLK

Tip (A)