Measurement Functions
TDR>Peak Mode
3M™ Dynatel™ Advanced Modular System 965AMS
Use Peak Mode to capture events that may be intermittent.
TDR>Peak Mode>Hook-Up
RED Ring (A)
BLK Tip (B)
TDR>Peak Mode>Operation
1.Press the blue key to enter the TDR mode. Use the up and down arrow keys to select Peak.
2.Press OK to display a trace.
3.The ‘live’ trace is displayed
continuously as a normal line. As a new maximum or minimum trace is detected, it will be displayed as a thin line along with the live trace.
130