3M™ Dynatel™ Advanced Modular System 965AMS

 

Specifications

Electrical Specifications

 

 

 

 

 

 

 

 

Functions

Range

Resolution

Accuracy

Caller ID (U.S. and

Date, time,

 

 

Canada only)

number, name

 

 

 

Carrier level

-4 to –32 dBm

1 dBm

±2 dBm

Short range wideband specifications (without SA option)

Wideband loss

-50 to +2 dBm,

0.1 dB, 100 Hz

±2 dB, 1% Hz

100, 135 Ω Zin

20 kHz to 1.2 MHz

 

 

Wideband tone

0 dBm, 20 k to 2.2 MHz

1 kHz

±+1 dB

output–100,135 Ω Zout

 

 

 

 

SA wideband specifications (with SA option)

 

 

Wideband loss

-85 to +5 dBm,

0.1 dB, 100 Hz

±1 dB, 1% Hz

100, 135 Ω Zin

20 kHz to 2.2 MHz

 

 

Wideband noise metallic

 

 

 

 

100, 135 Ω Zin

E filter

10-90 dBm

1 dB

±2 dB

E, F, G & G2 filters

F filter

20-90 dBm

1 dB

±2 dB

 

G filter

30-90 dBm

1 dB

±2 dB

Wideband spectral analysis

 

 

 

 

100, 135 Ω Zin

10 kHz to 2.2 MHz

0.5% of span

1%

Dynamic range

–90 dBm to +10 dBm

1 dB

 

Wideband tone output

0 dBm, 20 kHz to

1 kHz

±1 dB

–100,135 Ω Zout

2.2 MHz

 

±0.1% frequency

 

 

 

 

±0.5 kHz

Impulse noise counting

 

 

 

 

E, F, G & G2 filters

 

 

 

 

Counting interval

1-60 minutes

1 minute

±5%

Threshold

Lower limits: 30 dBrnC

1 dB

±1 dB (typical)

 

& E

 

 

 

40dBrnF

50dBrnG

100dBrn upper limit All 30 dB higher for N to Ground

Count capacity

9999

1

Filters:

 

300 Hz – 3400 Hz

C, E, F, G, G2

E filter

1 kHz – 50 kHz

and Psophometric

F filter

4.9 kHz – 245 kHz

for OUS

G filter

20 kHz – 1.1

MHz – 3 dB points

 

G2 filter

20 kHz – 2.2

MHz

Stored results

100 results total of all

 

 

(All Results)

types maximum

 

 

201