Self-Test Board

3M™ Dynatel™ Advanced Modular System 965AMS

Self-Test Board>Check RFL Performance

1.Connect the test leads as shown. Press the key on the 965AMS tester.

3965AMS

2.Press the

3.Press the

Setup

OK

key, enter 70°F (21°C) for temperature. key to accept.

4.Select Separate Pair hookup, then continue. You should see the following readings for different wire gauges (US and Canada).

AWG

 

DTS

DTF

 

 

DSTF

Min

Max

Min

Max

Min

Max

 

19

11910

12290

1170

1230

10730

11070

(3630)

(3747)

(357)

(375)

(3271)

(3375)

 

22

5986

6171

592

613

5393

5559

(1825)

(1881)

(180)

(187)

(1644)

(1695)

 

24

3755

3871

371

385

3383

3488

(1145)

(1180)

(109)

(117)

(1031)

(1063)

 

25

2970

3063

293

305

2676

2759

(905)

(934)

(89)

(93)

(816)

(841)

 

26

2347

2420

232

240

2114

2180

(716)

(738)

(71)

(73)

(645)

(665)

 

28

1479

1526

146

152

1332

1375

(451)

(465)

(44)

(46)

(406)

(419)

 

Ohms

99.3

102.5

9.8

10.2

89.5

92.3

198

Page 198
Image 198
3M 965AMS manual Self-Test BoardCheck RFL Performance, Dstf