3M™ Dynatel™ Advanced Modular System 965AMS |
Self-Test Board>Check RFL Performance
1.Connect the test leads as shown. Press the key on the 965AMS tester.
3965AMS
2.Press the
3.Press the
Setup
OK
key, enter 70°F (21°C) for temperature. key to accept.
4.Select Separate Pair hookup, then continue. You should see the following readings for different wire gauges (US and Canada).
AWG |
| DTS | DTF |
|
| DSTF | |
Min | Max | Min | Max | Min | Max | ||
| |||||||
19 | 11910 | 12290 | 1170 | 1230 | 10730 | 11070 | |
(3630) | (3747) | (357) | (375) | (3271) | (3375) | ||
| |||||||
22 | 5986 | 6171 | 592 | 613 | 5393 | 5559 | |
(1825) | (1881) | (180) | (187) | (1644) | (1695) | ||
| |||||||
24 | 3755 | 3871 | 371 | 385 | 3383 | 3488 | |
(1145) | (1180) | (109) | (117) | (1031) | (1063) | ||
| |||||||
25 | 2970 | 3063 | 293 | 305 | 2676 | 2759 | |
(905) | (934) | (89) | (93) | (816) | (841) | ||
| |||||||
26 | 2347 | 2420 | 232 | 240 | 2114 | 2180 | |
(716) | (738) | (71) | (73) | (645) | (665) | ||
| |||||||
28 | 1479 | 1526 | 146 | 152 | 1332 | 1375 | |
(451) | (465) | (44) | (46) | (406) | (419) | ||
| |||||||
Ohms | 99.3 | 102.5 | 9.8 | 10.2 | 89.5 | 92.3 |
198