3M™ Dynatel™ Advanced Modular System 965AMS

Measurement Functions

RFL>Single Pair, Multi-Section Operation

Special Requirement: Enter the cable temperature or the length, but not both. Only one parameter can be entered. There must be one unknown to solve the calculation.

For this example, we will use the cable temperature as the known value and the length will not be entered.

15. Press Manual background to enter an unknown length and move to the Temp section.

16. Use the blue keys to enter the cable temperature.

Press OK to return to the Multiple Gauge screen.