Specifications

Specifications

 

 

 

 

 

 

 

 

 

 

Electrical Specifications

 

 

 

 

 

 

 

 

 

 

 

Functions

Range

Resolution

Accuracy

Voltage (DC)

0 to 99.9 V

0.1 V

1%

± 0.5 V

 

 

100 to 300 V

1 V

3%

 

 

Voltage (AC)

0 to 99.9 V

0.1 V

1%

± 0.5 V

Meter resistance

100 to 250 V

1 V

3%

 

 

100 k or 1 m

 

 

 

 

 

 

Current

0 to 59.9 mA

0.1 mA

1%

± 0.3 mA

 

 

60 to 110 mA

0.1 mA

2%

 

 

Shunt resistance

430 Ω

 

 

 

 

Resistance

0 to 9999 Ω

1 Ω

1%

± 5 Ω

With CO voltage

0 to 9999 Ω

1 Ω

1%

± 50 Ω

 

 

10 k to 99.9 kΩ

0.1 kΩ

1%

 

 

 

 

100 k to 999 kΩ

1 kΩ

3%

 

 

 

 

1 M to 9.9 MΩ

10 kΩ

3%

 

 

 

 

10 M to 99 MΩ

0.1 MΩ

5%

 

 

 

 

100 M to 990 MΩ

1 MΩ

10%

 

Opens (no noise)

0 to 3,000 ft

1 ft (1 m)

1%

± 3 ft (1 m)

 

 

(0 to 1,000 m)

 

 

 

 

 

 

3,000 to 10,000 ft

1 ft (1 m)

3%

 

 

 

 

(1 km to 3 km)

 

 

 

 

 

 

10,000 to 50,000 ft

10 ft (10 m)

5%

 

 

 

 

(3 km to 15 km)

 

 

 

 

 

 

50,000 to 100,000 ft (15

100 ft (100 m)

10%

 

 

 

km to 30 km)

 

 

 

 

RFL

 

 

 

 

 

 

Fault range

0 to 20 MΩ

 

 

Resistance to

0 to 99.99 Ω

RTS 0.01 Ω

0.1% of RTS ± 0.01 Ω1

Fault (no noise)

100 to 999.9 Ω

RTS 0.1 Ω

0.2% of RTS ± 0.01 Ω1

 

 

1 k to 3 kΩ

RTS 1.0 Ω

1.0% of RTS ± 0.01 Ω1

Wet section test

 

 

 

 

 

 

Loop resistance Resistive

0 to 7 kΩ

 

 

balance

0 to 3.5 kΩ

5%

 

 

Loop resistance

0 to 99.9 Ω

0.01 Ω

0.1% ± 0.01 Ω

 

 

100 to 999.9 Ω

0.1 Ω

0.2% ± 0.01 Ω

 

 

1000 to 7000 Ω

1 Ω

1.0% ± 0.01 Ω

Resistance difference

0 to 99.99 Ω

0.01 Ω

1% of loop resistance

 

 

 

 

 

± 0.01 Ω

Note: 1All resistance to fault measurement accuracies have an added factor of (2x10-8) Rf ohms (Rf =fault resistance in ohms)