3M™ Dynatel™ Advanced Modular System 965AMS |
|
| Specifications | ||||
Specifications |
|
|
|
| |||
|
|
|
|
|
| ||
Electrical Specifications |
|
|
| ||||
|
|
|
|
|
|
|
|
Functions | Range | Resolution | Accuracy | ||||
Voltage (DC) | 0 to 99.9 V | 0.1 V | 1% | ± 0.5 V | |||
|
| 100 to 300 V | 1 V | 3% |
|
| |
Voltage (AC) | 0 to 99.9 V | 0.1 V | 1% | ± 0.5 V | |||
Meter resistance | 100 to 250 V | 1 V | 3% |
|
| ||
100 k or 1 m |
|
|
|
|
|
| |
Current | 0 to 59.9 mA | 0.1 mA | 1% | ± 0.3 mA | |||
|
| 60 to 110 mA | 0.1 mA | 2% |
|
| |
Shunt resistance | 430 Ω |
|
|
|
| ||
Resistance | 0 to 9999 Ω | 1 Ω | 1% | ± 5 Ω | |||
With CO voltage | 0 to 9999 Ω | 1 Ω | 1% | ± 50 Ω | |||
|
| 10 k to 99.9 kΩ | 0.1 kΩ | 1% |
|
| |
|
| 100 k to 999 kΩ | 1 kΩ | 3% |
|
| |
|
| 1 M to 9.9 MΩ | 10 kΩ | 3% |
|
| |
|
| 10 M to 99 MΩ | 0.1 MΩ | 5% |
|
| |
|
| 100 M to 990 MΩ | 1 MΩ | 10% |
| ||
Opens (no noise) | 0 to 3,000 ft | 1 ft (1 m) | 1% | ± 3 ft (1 m) | |||
|
| (0 to 1,000 m) |
|
|
|
| |
|
| 3,000 to 10,000 ft | 1 ft (1 m) | 3% |
|
| |
|
| (1 km to 3 km) |
|
|
|
| |
|
| 10,000 to 50,000 ft | 10 ft (10 m) | 5% |
|
| |
|
| (3 km to 15 km) |
|
|
|
| |
|
| 50,000 to 100,000 ft (15 | 100 ft (100 m) | 10% |
| ||
|
| km to 30 km) |
|
|
|
| |
RFL |
|
|
|
|
|
| |
Fault range | 0 to 20 MΩ | — | — |
|
| ||
Resistance to | 0 to 99.99 Ω | RTS 0.01 Ω | 0.1% of RTS ± 0.01 Ω1 | ||||
Fault (no noise) | 100 to 999.9 Ω | RTS 0.1 Ω | 0.2% of RTS ± 0.01 Ω1 | ||||
|
| 1 k to 3 kΩ | RTS 1.0 Ω | 1.0% of RTS ± 0.01 Ω1 | |||
Wet section test |
|
|
|
|
|
| |
Loop resistance Resistive | 0 to 7 kΩ | — | — |
|
| ||
balance | 0 to 3.5 kΩ | — | 5% |
|
| ||
Loop resistance | 0 to 99.9 Ω | 0.01 Ω | 0.1% ± 0.01 Ω | ||||
|
| 100 to 999.9 Ω | 0.1 Ω | 0.2% ± 0.01 Ω | |||
|
| 1000 to 7000 Ω | 1 Ω | 1.0% ± 0.01 Ω | |||
Resistance difference | 0 to 99.99 Ω | 0.01 Ω | 1% of loop resistance | ||||
|
|
|
|
| ± 0.01 Ω |
Note: 1All resistance to fault measurement accuracies have an added factor of
199