3M 965AMS Auto Test>Vacant Wideband, Measurement Functions, Insertion, Single, Sweep Frequencies

Models: 965AMS

1 204
Download 204 pages 1.32 Kb
Page 174
Image 174
Auto Test>Vacant Wideband

Measurement Functions

3M™ Dynatel™ Advanced Modular System 965AMS

Auto Test>Vacant Wideband

Use Vacant Wideband to perform an automatic sequence of tests on Vacant Wideband circuits. The tests include: DC Voltage, AC Voltage, DC Resistance, Opens, % Capacitance Balance, Load Coil, Wideband Loss, Wideband Noise, Longitudinal Balance, Slope, Resistance Balance (loop) and Resistance Balance (% diff).

Note: You must use a 3MDynatelFar End Device II 1342 or 1343 to use the Vacant Wideband function.

Insertion Loss Frequencies and Sweep Frequencies by Service Type

Insertion

Single

Sweep Frequencies

Loss

Frequency*

 

Sweeps

 

 

Pots

1004 Hz

404, 804, 1004, 1204, 1404, 1604, 1804, 2004,

 

 

2804, 3004 (Hz)

56k

28 kHz

20, 28, 32, 40, 48, 82 (kHz)

64k

32 kHz

20, 28, 32, 40, 48, 82 (kHz)

ISDN

40 kHz

20, 28, 32, 40, 48, 60, 70, 82 (kHz)

HDSL

196 kHz

20, 30, 50, 70, 90, 110, 130, 196, 400 (kHz)

T1

772 kHz

200, 400, 500, 700, 772, 1024 (kHz)

E1

1024 kHz

200, 400, 500, 700, 772, 1024 (kHz)

ADSL

138 kHz

20, 30, 50, 69, 90, 110, 138, 276, 400, 600, 800,

 

 

1000, 1100 (kHz)

H2/4ACC

196 kHz

50, 80, 130, 196, 250, 300, 350 (kHz)

H4RACC**

N/A

20, 30, 50, 70, 90, 110, 130, 196, 400 (kHz)

H4NACC***

N/A

20, 30, 50, 70, 90, 110, 130, 196, 400 (kHz)

ADSL2

138 kHz

20, 30, 50, 69, 110, 138, 276, 400, 600, 800, 1100,

 

 

1500, 1800, 2200 (kHz)

*Pass/Fail provided for Single Frqeuency when measuring just Single Frequency or in Sweep Mode.

**Pass/Fail provided for 50 kHz, 90 kHz and 130 kHz

***Pass/Fail provided for 50 kHz, 90 kHz, 130 kHz and 196 kHz