3M 965AMS manual This trace shows a resistive fault at 219 feet

Models: 965AMS

1 204
Download 204 pages 1.32 Kb
Page 122
Image 122
6.This trace shows a resistive fault at 219 feet.
8.
The Auto TDR mode automatically finds potential faults and displays an icon that represents
the type of fault. Press Auto TDR to use this
function.
5.
TDR>Single Trace Mode>Operation
3. This screen shows the end of a pair at 205 feet.
Measurement Functions

3M™ Dynatel™ Advanced Modular System 965AMS

4.Use the TDR Controls section in this chapter to see all of the parameters that you can adjust.

6.This trace shows a resistive fault at 219 feet.

7.The Auto TDR is not a live trace, but you can use the Gain, Cable length, Span and Filter functions.

If you change the circuit you must capture a new trace. Press Live TDR then

press Auto TDR .

9.This trace shows an open at 322 feet.