Test Pair 1
3M™ Dynatel™ Advanced Modular System 965AMS | Measurement Functions |
Auto Test>Active POTS>Operation
11. Press to start the Active POTS tests.
Note: The volume of the test can be adjusted using the up and down arrows.
12.Certain auto test results are compared against pass/fail limits to provide a quick- look at the pair condition. The pass/fail status is indicated in the results box by an “OK” for pass, a “Yield” sign for marginal and a “Stop” sign for fail.
13.Press Val. to see the actual test results.