ADTRAN 6000 Series system manual Traps Supported by the Tracer, Mib, Trap This trap indicates that

Models: 6000 Series

1 132
Download 132 pages 36.21 Kb
Page 111
Image 111

TRACER 6000 Series Integrated System Manual

Section 7 MIBs

 

 

3.TRAPS SUPPORTED BY THE TRACER 64x0

The TRACER 64x0 supports the traps described in Table 3.

Table 3. Traps Supported by the TRACER 64x0

MIB

Trap

This trap indicates that....

 

 

 

TRACER6000.mib

adTRACERColdStart

the unit has powered up.

 

 

 

 

adTRACERYellow

a change in the YELLOW alarm state has occurred

 

 

and the YELLOW alarm is now active.

 

 

 

 

adTRACERAIS

a change in the Alarm Indication Signal (AIS) has

 

 

occurred and the AIS alarm is active.

 

 

 

 

adTRACERRedAlarm

a change in the RED alarm state has occurred and

 

 

the RED alarm is now active.

 

adTRACERLOS

a change in the Loss of Signal (LOS) state has

 

 

occurred and the LOS alarm is active.

 

 

 

 

adTRACERBPV

a change in the BiPolar Violation (BPV) state has

 

 

occurred and the BPV alarm is active.

 

 

 

 

adTRACERRA

a change in the Frame RA (Remote Alarm) state has

 

 

occurred and the RA alarm is active.

 

adTRACEROOF

a change in the Out Of Frame (OOF) state has

 

 

occurred and the OOF alarm is active.

 

 

 

 

adTRACERCV

a change in the Code Violation (CV) state has

 

 

occurred and the CV alarm is active.

 

 

 

 

adTRACERCRC

a change in the Cyclic Redundancy Check (CRC)

 

 

state has occurred and the CRC alarm is active.

 

adTRACERmfLOF

a change in the Loss of Multiframe (LOMF) state has

 

 

occurred and the LOMF alarm is active.

 

 

 

 

adTRACERmfLOS

a change in the Multiframe Loss of Signal (LOS)

 

 

state has occurred and the Multiframe LOS alarm is

 

 

active.

 

 

 

 

adTRACERmfAIS

a change in the Multiframe Alarm Indication Signal

 

 

(AIS) state has occurred and the Multiframe AIS

 

 

alarm is active.

 

adTRACERmfRA

a change in the Multiframe Remote Alarm (RA) has

 

 

occurred and the Multiframe RA alarm is active.

 

 

 

 

adTRACERlineLoopback

a change in the line loopback state has occurred and

 

 

the line loopback is active.

 

 

 

 

adTRACERlinkLoopback

a change in the link loopback state has occurred and

 

 

the link loopback is active.

 

adTRACERYellowOff

a change in the YELLOW alarm state has occurred

 

 

and the YELLOW alarm is now inactive.

 

 

 

 

adTRACERAISoff

a change in the Alarm Indication Signal (AIS) has

 

 

occurred and the AIS alarm is inactive.

 

 

 

 

adTRACERRedAlarmOff

a change in the RED alarm state has occurred and

 

 

the RED alarm is now inactive.

 

adTRACERLOSoff

a change in the Loss of Signal (LOS) state has

 

 

occurred and the LOS alarm is inactive.

 

 

 

612806420L1-1F

Copyright © 2005 ADTRAN, Inc.

111

Page 111
Image 111
ADTRAN 6000 Series system manual Traps Supported by the Tracer, Mib, Trap This trap indicates that