TRACER 6000 Series Integrated System Manual

Section 4 Network Turnup Procedure

 

 

Instructions for Installing Network Modules

1.Remove power from the unit.

2.Remove the blank panel plate (if necessary).

3.Slide the network module into the network slot until the module is firmly seated against the front of the chassis.

4.Secure the screws at both edges of the module.

5.Install the optional hardware components (when necessary). For example, for the E1 network module, an optional BNC breakout panel is available.

6.Connect the cables to the associated device(s).

7.Restore power to the unit.

9.CONNECTING THE MODULE INTERFACES

Quad T1 Module Interfaces

The physical T1 interfaces are provided using four RJ-45 ports located on the module. Straight-through T1 interface cables can be used to interface to any standard T1 DTE device (not supplied).

T1 crossover cables are needed when connecting two TRACER 64x0 T1 ports in back-to-back operation.

Quad Ethernet Switch Module

The physical Ethernet interfaces are provided using four RJ-45 jacks. Ethernet cables are not supplied with your shipment. Connect any standard Ethernet device to one of the switch ports located on the rear of the unit.

Quad E1 (120) Module Interfaces

The physical E1 interfaces are provided using four RJ-45 ports located on the module. Straight-through E1 interface cables can be used to interface to any standard E1 DTE device (not supplied).

E1 crossover cables are needed when connecting two TRACER 64x0 E1 ports in back-to-back operation.

Quad E1 (75) Module Interfaces

The physical E1 interfaces are provided using a single DB-25 interface, an adapter cable, and a BNC breakout panel. Connect one end of the adapter cable (labeled TO RADIO) to the module’s DB-25 connector, and then attach the other end of the cable (labeled TO PANEL) to the BNC breakout panel. The 75unbalanced interfaces provided by the breakout panel are available for connection to standard E1 DTE devices (see Figure 6 on page 52).