Section 5 User Interface Guide

TRACER 6000 Series Integrated System Manual

 

 

>SYSTEM CONFIGURATION > CRAFT PORT BAUD

Specifies the baud rate of the port. Select either 9600 (default), 19200, 38400, 57600, or 115200 bps. If you are using the CRAFT port for modem access, ensure that the CRAFT port rate matches the modem baud rate.

>SYSTEM CONFIGURATION > INACTIVITY LOGOUT

This option defines the amount of time in minutes the user can stay connected without any activity on the CRAFT port before the user is automatically logged out of the system. Select one of the following: 5 MIN,

10MIN (default), 15 MIN, 30 MIN, 45 MIN, 60 MIN, or OFF.

Changes to the INACTIVITY LOGOUT setting do not apply to the current session. All changes take affect at the next login to the system menus.

>SYSTEM CONFIGURATION > PASSWORD

Sets the password for password protection of the TRACER 64x0 terminal interface. Enter up to eight alphanumeric characters. The system password is case sensitive.

The default password for the TRACER 64x0 is password.

>SYSTEM CONFIGURATION > PERFORMANCE STATS (CLEAR)

Resets all system error counters for the TRACER 64x0.

>SYSTEM CONFIGURATION > FACTORY DEFAULTS

Resets the system to the factory default settings. The configured IP ADDRESS, SUBNET MASK, and DEFAULT GATEWAY are not defaulted during a factory default. When you select this command, the following confirmation message appears:

Are you sure you want to restore factory Defaults? Y or N

Press Y to restore factory defaults or N to cancel this command.

The TOTAL ACTIVE CHANNELS parameter (on the Datapath Provisioning menu page) is reset to the factory default value (8). Performing a factory default on any system with less than eight active channels results in an RF link loss.

62

Copyright © 2005 ADTRAN, Inc.

612806420L1-1F

Page 62