ADTRAN 6000 Series system manual Quad Ethernet

Models: 6000 Series

1 132
Download 132 pages 36.21 Kb
Page 42
Image 42

 

Section 3 Engineering Guidelines

TRACER 6000 Series Integrated System Manual

 

 

 

 

 

 

Table 15. At-A-Glance Specifications (Continued)

 

 

 

 

 

Hardware

Description

Specification

 

 

 

 

Mechanical and Environmental

 

 

 

Operating Temperature

-25°C to 65°C

 

 

 

 

 

 

 

1.7 inch (4.4 cm) H

 

 

Size

17.2 inch (43.7 cm) W

 

 

 

11.4 inch (28.9 cm) D

 

 

 

 

 

 

Humidity

95 percent, noncondensing

 

 

 

 

 

 

Weight

7 lbs (3.18 kg)

 

 

 

Power

 

 

 

 

Input Voltage

21 to 60 VDC, either polarity referenced to ground

 

 

 

 

 

 

Power Consumption

< 25 W

 

 

 

 

 

 

Connector

2-pin terminal block (DC)

 

 

 

 

 

 

Fuse

2 A, 250 V slow-blo fuse (2-inch)

 

 

 

Network Modules

 

 

Quad T1 Module

Connection

Four RJ-45 interfaces

 

 

 

 

 

 

Capacity

4xT1 (ANSI T1.403, AT&T® 54016 and 62411)

 

 

Line Code

B8ZS (default), AMI

 

 

 

 

 

 

Alarms

AIS, Red, Yellow, BPVs, LOS

 

 

 

Quad Ethernet

Connection

Four RJ-45 interfaces

Switch Module

 

 

Interface Type

Four 10BaseT/100BaseTX interfaces with auto MDI/MIDX

 

 

 

 

 

crossover

 

 

 

 

 

 

Flow Control

Back-pressure flow control on half-duplex interfaces

 

 

 

Pause-frame flow control on full-duplex interfaces

 

 

 

Quad E1 Module

Connection

Four RJ-45 interfaces

(120Ω Interface)

 

 

Capacity

4xE1 (CCITT G.703)

 

 

 

 

 

 

 

 

Line Code

HDB3 (default), AMI

 

 

 

 

 

 

Alarms

LOS, LCV, AIS, RMT, OOF, CRC

 

 

 

 

 

 

Loopbacks

Local and remote line and link

 

 

 

Quad E1 Module

Connection

Single DB-25 connector on module; 75Ω unbalanced interface

(75Ω Interface)

 

available using BNC breakout panel

 

 

Capacity

4xE1 (CCITT G.703)

 

 

 

 

 

 

Line Code

HDB3 (default), AMI

 

 

 

 

 

 

Alarms

LOS, LCV, AIS, RMT, OOF, CRC

 

 

 

 

 

 

Loopbacks

Local and remote line and link

 

 

 

 

42

Copyright © 2005 ADTRAN, Inc.

612806420L1-1F

Page 42
Image 42
ADTRAN 6000 Series system manual Quad Ethernet