ADTRAN 6000 Series system manual Mgmt 10/100BaseT/TX Connection RJ-48C

Models: 6000 Series

1 132
Download 132 pages 36.21 Kb
Page 34
Image 34

Section 3 Engineering Guidelines

TRACER 6000 Series Integrated System Manual

 

 

 

A

C

F

Network

DC Power

Antenna

Module Slots

Connection

Connector

B

D

E

G

Ethernet

Interface

Fuse

Alarm

Ground

 

 

Contacts

Lug

 

 

Figure 3. TRACER 64x0 Rear Panel

 

 

Table 6. Rear Panel Description1

 

Name

Connector

Description

 

 

 

 

A

Network Module

N/A

Dual network module slots for system flexibility (shown

 

Slots

 

with a single 4xT1 module and a Quad Ethernet Switch

 

 

 

module installed)

B

MGMT

RJ-45

 

C

DC Power

Terminal block

10/100BaseT/TX Ethernet interface for SNMP, TFTP, and Telnet access

21 to 60 VDC power source connection (either polarity referenced to ground)

D

Fuse

N/A

2A, 250 V, 2-inch slo-blo fuse

E

Alarm

Terminal block

External alarm monitoring system connection

F

Antenna

N-type (female)

Antenna feedline cable connection

G

Ground Lug

N/A

Earth ground connection

1 Detailed discussions (including pinouts) of rear panel components (where applicable) follow the table.

MGMT 10/100BaseT/TX Connection (RJ-48C)

The physical Ethernet interface is provided by a single RJ-48C jack (labeled MGMT) that delivers 10/100BaseT/TX for LAN connectivity. The MGMT port is used for Telnet, SNMP, and TFTP access and is not a router interface. The MGMT port has a green LINK LED to indicate a valid link and an amber ACT LED that flashes with data activity on the interface. Table 7 shows the pinout.

 

 

Table 7. MGMT 10/100BaseT/TX Interface Pinout

 

 

 

 

Pin

Name

 

Description

 

 

 

 

1

TX1

 

Transmit positive

 

 

 

 

2

TX2

 

Transmit negative

 

 

 

 

3

RX1

 

Receive positive

 

 

 

 

4,5

 

Unused

 

 

 

 

6

RX2

 

Receive negative

 

 

 

 

7, 8

 

Unused

 

 

 

 

34

Copyright © 2005 ADTRAN, Inc.

612806420L1-1F

Page 34
Image 34
ADTRAN 6000 Series system manual Mgmt 10/100BaseT/TX Connection RJ-48C