Section 7 MIBs

TRACER 6000 Series Integrated System Manual

 

 

Table 3. Traps Supported by the TRACER 64x0 (Continued)

MIB

Trap

This trap indicates that....

TRACER6000.mib

adTRACERBPVoff

a change in the BiPolar Violation (BPV) state has

 

 

occurred and the BPV alarm is inactive.

 

 

 

 

adTRACERRAoff

a change in the Frame RA (Remote Alarm) state has

 

 

occurred and the RA alarm is inactive.

 

 

 

 

adTRACEROOFoff

a change in the Out Of Frame (OOF) state has

 

 

occurred and the OOF alarm is inactive.

 

adTRACERCVoff

a change in the Code Violation (CV) state has

 

 

occurred and the CV alarm is inactive.

 

 

 

 

adTRACERCRCoff

a change in the Cyclic Redundancy Check (CRC)

 

 

state has occurred and the CRC alarm is inactive.

 

 

 

 

adTRACERmfLOFoff

a change in the Loss of Multiframe (LOMF) state has

 

 

occurred and the LOMF alarm is inactive.

 

adTRACERmfLOSoff

a change in the Multiframe Loss of Signal (LOS)

 

 

state has occurred and the Multiframe LOS alarm is

 

 

inactive.

 

 

 

 

adTRACERmfAISoff

a change in the Multiframe Alarm Indication Signal

 

 

(AIS) state has occurred and the Multiframe AIS

 

 

alarm is inactive.

 

 

 

 

adTRACERmfRAoff

a change in the Multiframe Remote Alarm (RA) has

 

 

occurred and the Multiframe RA alarm is inactive.

 

adTRACERlineLoopbackOff

a change in the line loopback state has occurred and

 

 

the line loopback is inactive.

 

 

 

 

adTRACERlinkLoopbackOff

a change in the link loopback state has occurred and

 

 

the link loopback is inactive.

 

 

 

 

adTRACERLinkDown

the RF link is down.

 

 

 

 

adTRACERLinkUp

the RF link is up.

 

 

 

 

adTRACERRFCLinkDown*

the RFC link is down between the Indoor Unit (IDU)

 

 

and Outdoor Unit (ODU). This trap only applies to

 

 

TRACER split systems.

 

 

 

 

adTRACERRFCLinkUp*

the RFC link is up between the IDU and ODU. This

 

 

trap only applies to TRACER split systems.

 

adTRACERRxLow

the receive level is within 10 dB of sensitivity and the

 

 

RF Low alarm is active.

 

 

 

 

adTRACERRxLevel

a change in receive level has occurred and the

 

 

receive level is within normal range.

 

 

 

 

adTRACERcurrThrsESon

the threshold for current Errored Seconds (ES) has

 

 

been exceeded.

 

adTRACERcurrThrsESoff

the threshold for current ES has not been exceeded.

 

 

 

 

adTRACERcurrThrsSESon

the threshold for current Severely Errored Seconds

 

 

(SES) has been exceeded.

 

 

 

 

adTRACERcurrThrsSESoff

the threshold for current SES has not been

 

 

exceeded.

* Not supported in TRACER 64x0 models. Listed trap only applies to TRACER split systems.

112

Copyright © 2005 ADTRAN, Inc.

612806420L1-1F

Page 112
Image 112
ADTRAN 6000 Series system manual Copyright 2005 ADTRAN, Inc