Section 6 DLP-1

TRACER 6000 Series Integrated System Manual

 

 

Perform one of the following steps:

1.Connecting a VT100 terminal to the TRACER 64x0:

Set the parameters of the VT100 terminal or PC to match the default settings on the TRACER 64x0:

9600 baud rate

8 data bits

No parity

1 stop bit

No flow control

If the terminal has a parallel setting, disable this setting and use the serial port.

Using the CRAFT Port

Plug the DB-9 male end of the data cable into the TRACER 64x0 CRAFT port on the front of the unit. Make the connection to the VT100 terminal as appropriate for your equipment.

2.Connecting a PC emulating a VT100 terminal to the TRACER 64x0:

Most PCs or laptops can run communications software that emulates a VT100 terminal. Examples include Windows programs such as Terminal® or Hyperterminal®. However, there are many other adequate, commercially available software packages which will allow your PC or laptop to emulate a VT100 terminal.

Set the parameters of the communications software to match the default settings on the TRACER 64x0:

9600 baud rate

8 data bits

No parity

1 stop bit

No flow control

Set the PC for direct connect (instead of dial up connection) on the appropriate com port.

Using the CRAFT Port

Plug the DB-9 male end of the data cable into the TRACER 64x0 CRAFT port on the front of the unit. Make connection to the PC or laptop as appropriate for your equipment.

You are now ready to log in to the TRACER 64x0 as described in DLP-2, Logging into the TRACER 64x0, on page 93.

92

Copyright © 2005 ADTRAN, Inc.

612806420L1-1F

Page 92
Image 92
ADTRAN 6000 Series system manual Perform one of the following steps, Using the Craft Port