Section 3 Engineering Guidelines

TRACER 6000 Series Integrated System Manual

 

 

4xE1 Module with 120Interface

The 4xE1 network module provides four E1 interfaces (through four RJ-45 connectors) that provide the following functions:

AMI or HDB3 coding

Framed, multi-framed, and unframed framing support

Network performance monitoring and reporting

Test loopbacks (both line and link)

Table 12 provides the RJ-45 interface pinout for the 4xE1 network module.

Table 12. 4xE1 Module with 120Interface RJ-45 Connector Pinout

Pin

Name

Description

 

 

 

1

TX Tip

Transmit signal (Tip)

 

 

 

2

TX Ring

Transmit signal (Ring)

 

 

 

3

Unused

 

 

 

4

RX Tip

Receive signal (Tip)

 

 

 

5

RX Ring

Receive signal (Ring)

 

 

 

6–8

Unused

 

 

 

4xE1 Module with 75Interface

The 4xE1 network module provides four E1 interfaces (through a single DB-25 interface) that provide the following functions:

AMI or HDB3 coding

Framed, multi-framed, and unframed framing support

Network performance monitoring and reporting

Test loopbacks (both line and link)

Table 13 on page 39 provides the DB-25 interface pinout for the 4xE1 network module. A separate breakout panel is available to provide 75BNC unbalanced interfaces (see Table 14 on page 39 for the pinout of the 75cable). Figure 4 displays the E1 breakout panel.

38

Copyright © 2005 ADTRAN, Inc.

612806420L1-1F

Page 38
Image 38
ADTRAN 6000 Series system manual 4xE1 Module with 120Ω Interface, 4xE1 Module with 75Ω Interface