ADTRAN 6000 Series system manual XE1 Module with 75Ω Interface DB-25 Connector Pinout

Models: 6000 Series

1 132
Download 132 pages 36.21 Kb
Page 39
Image 39

TRACER 6000 Series Integrated System Manual

Section 3 Engineering Guidelines

 

 

 

 

 

 

 

 

Table 13. 4xE1 Module with 75Interface DB-25 Connector Pinout

 

 

 

 

 

 

Pin

 

Name

 

Description

 

 

 

 

 

 

 

1

 

E1D RX

Receive signal for E1 D interface

 

 

 

 

 

 

 

 

 

2

 

E1D TX

Output signal for E1 D interface

 

 

 

 

 

 

 

 

 

3

 

GND

Ground

 

 

 

 

 

 

 

 

 

4

 

E1C RX

Receive signal for E1 C interface

 

 

 

 

 

 

 

 

 

5

 

E1C TX

Output signal for E1 C interface

 

 

 

 

 

 

 

 

 

6

 

GND

Ground

 

 

 

 

 

 

 

 

 

7

 

E1B RX

Receive signal for E1 B interface

 

 

 

 

 

 

 

 

 

8

 

E1B TX

Output signal for E1 B interface

 

 

 

 

 

 

 

 

 

9

 

GND

Ground

 

 

 

 

 

 

 

 

 

10

 

E1A RX

Receive signal for E1 A interface

 

 

 

 

 

 

 

 

 

11

 

E1A TX

Output signal for E1 A interface

 

 

 

 

 

 

 

 

 

12-25

 

GND

Ground

 

 

 

 

 

 

 

 

 

 

Table 14. DB-25 to 75Unbalanced Cable Pinout

 

 

 

 

 

 

 

E1 Cable Interface

 

DB-25 Male

 

DB-25 Male

 

(TRACER Side)

 

(Breakout Panel)

 

 

 

 

 

 

Channel 1 Input

 

 

10

 

14

 

 

 

 

 

Channel 1 Output

 

11

 

3

 

 

 

 

 

 

Channel 2 Input

 

 

7

 

17

 

 

 

 

 

Channel 2 Output

 

8

 

6

 

 

 

 

 

 

Channel 3 Input

 

 

4

 

20

 

 

 

 

 

Channel 3 Output

 

5

 

9

 

 

 

 

 

 

Channel 4 Input

 

 

1

 

23

 

 

 

 

 

Channel 4 Output

 

2

 

12

 

 

 

 

 

 

Ground

 

 

All other pins

 

All other pins

 

 

 

 

 

 

 

612806420L1-1F

Copyright © 2005 ADTRAN, Inc.

39

Page 39
Image 39
ADTRAN 6000 Series system manual XE1 Module with 75Ω Interface DB-25 Connector Pinout, DB-25 to 75Ω Unbalanced Cable Pinout