Section 6 DLP-6

TRACER 6000 Series Integrated System Manual

 

 

Perform the following steps in the order listed.

1.Connect to the TRACER 64x0 using the front panel DB-9 CRAFT interface.

If you are not already connected to the unit’s CRAFT interface (either with a VT100 compatible terminal or with a PC running VT100 emulation software), follow the procedure in DLP-1,Connecting a VT100 Terminal or PC to the CRAFT Port, on page 91. Connecting to the CRAFT interface limits the upgrade procedure to XMODEM only.

The TRACER 64x0 supports serial baud rates of up to 115200 bps. Changing the speed on the CRAFT interface will significantly reduce upgrade time. The TRACER 64x0 and the VT100 terminal (or PC with emulation software) must be configured for the same baud rate.

2.Log in to the unit (see DLP-2,Logging into the TRACER 64x0, on page 93 for details).

3.Press m to go to the Main menu page.

4.Select the MANAGEMENT/UTILITIES menu and press <Enter>.

5.Select the FIRMWARE UPGRADE UTILITY menu and press <Enter>.

6.Go to the FILE XFER METHOD menu and select XMODEM.

7.Select the UPGRADE DESTINATION. (Valid selections for XMODEM are LOCAL IDU and LOCAL ODU).

8.View CURRENT UPDATE STATUS to verify the progress of the current firmware update or to identify any errors encountered during the download.

9.Select START from the COMMAND menu to start the update.

When the TRACER 64x0 is ready to receive the XMODEM upload, the menu screen clears and displays XMODEM waiting for start....<Ctrl-X> twice to Cancel. If this does not appear, please review the steps above for possible configuration errors.

10.From the terminal emulation software, begin the XMODEM upload by using the appropriate command sequence. This may take several minutes.

If necessary, refer to the terminal emulation software documentation for help. Also, when specifying the filename, ensure that the file transferred is the one provided by ADTRAN. Otherwise, the update will not complete successfully.

Because XMODEM data is being transferred inband through the menu interface, the VT100 menus of the TRACER 64x0 will be inoperable from the CRAFT interface. You can cancel the update at any time within the terminal emulation software. (Please consult the documentation provided by the terminal emulation software to determine how to do this).

11.When the update has successfully completed, IDLE displays in the CURRENT UPDATE STATUS field and

UPGRADE FINISHED SUCCESSFULLY displays in the PREVIOUS UPDATE STATUS field.

The TRACER 64x0 will restart immediately and resume operation. During reset and initialization, the RF link between the units will not be operational.

Alternatively, if the unit is part of a management cluster connected to the local network, you may use a PC connected to the network to Telnet into the unit. By using the 10/100BaseT/TX MGMT port, the TRACER 64x0 may be quickly upgraded using TFTP, provided there is a TFTP server on the local network. (See DLP-5, Updating the Firmware Using TFTP, on page 103 for more details.)