Telephone Connections

Registration

The Radionics D9112 Control/Communicator panel is registered with the Federal Communication Commission under part 68, for connection to the public telephone system using an RJ31X jack installed by your local phone company.

FCC Registration Number: AJ9USA-18808-AL-E

Ringer Equivalence: 0.1A 0.2B

Notification

Do not connect registered equipment to party lines or coin-operated telephones. You must notify the local telephone company and supply them with the following information before connecting the panel to the telephone network.

The particular line you are going to connect the panel to

Make (Radionics), model (D9112), and serial number of the panel

FCC registration number and ringer equivalence for the panel (see Registration above)

Location

To prevent jamming of signals, wire the RJ31X jack before the in-house phone system to support line seizure. See Figure 6. Install the jack on the street side of the phone switch, wired ahead of any PBX equipment. Line seizure provides for a temporary interruption of normal phone usage while the communicator transmits data. After installation, confirm that the panel seizes the line, acquires dial tone, reports correctly to the receiver, and releases the phone line to the in-house phone system.

PREMISES FULL MODULAR PHONE JACK

PHONE

R1

%

T1

1

 

 

2

 

 

3

R

 

4

INCOMING

T

5

 

TELCO LINE

6

7

8

RJ31X MODULE

Figure 6: RJ31X Wiring

 

D9112