Make the Telephone Connections

See Telephone Connections. If you are connecting the D9112 to a ground start phone
system, you need to install D136 relay, see Install Modules and Relays on the previous
page.

Connect the On-Board Points and Command Centers

Connect the on-board point and command center wiring to the D9112. See the On-Board
Points and Arming Devices sections for instructions.

Power Up

Reconnect the battery and then plug in the transformer. Remember the buzzer sounds
for 10 seconds when you first power up the panel.
Leave the reset pin locked down for now.
Yellow Charging Status LED doesn’t go out: If the yellow charging status LED doesn’t
go out within 5 minutes of powering up the panel, the battery may be deeply discharged,
or you may have connected too many powered devices to the panel. Combined
continuous current draw for terminals 3, 8, 24, and 32, the Accessory Connector (J2),
and the Expansion Port (J4) cannot exceed 1.4A. See the Power Outputs section for
help.
Programming the Panel
If you haven’t created a program for the panel, review the D9112 Program Entry Guide
(74-06145-000). Check to be certain you have all the required accessory modules
installed for the features you want to use.
Use the D5200 Programmer or the RAM II remote programmer to load your custom
program into the panel.
Move the reset pin to the normal position. See Figure 3. The panel transmits reboot and
battery reports to the receiver.
Install the Point Chart Label
Radionics recommends you fill out the Point Chart Label (79-06660-000) provided in the
literature pack and install it inside the enclosure doors for all systems.
Point chart label required for fire systems with verification points: You must install
the point chart label for fire or combined fire/burglary systems using verification points.
Use the program record sheet to gather the information you need to fill out the point
chart. Install the label on the enclosure door as shown in figure 2. To avoid smearing your
entries on the chart, use the label's peel off backing to press the label in place.