74-06144-000-C 2/96

D122 DUAL

BATTERY HARNESS

-

+

-

+

 

 

D8004

 

 

TRANSFORMER

16 VAC

 

ENCLOSURE

 

 

 

40 VA

 

 

ARMING STATION

 

 

60 HZ

 

 

 

TRANSFORMER

 

 

PARALLEL

PRINTER

D9131 PARALLEL

PRINTER

D9112

AS REQUIRED

D8132

BATTERY

CHARGER

D126

BATTERY 12V 7Ah

D126

BATTERY 12V 7Ah

 

 

 

 

 

D1255

 

 

 

 

 

UP TO EIGHT

D1640

 

 

D9112

17-05823-000

SUPERVISED

 

 

 

Operation Monitor

P

P

LEDs Off When Normal

Digital Alarm Communicator Transmitter

Pulses When Normal

 

 

 

 

 

Flickers When Ringing GRN

P

S

YEL

Charging Status

 

Solid When Held In Reset

 

 

 

 

P

 

 

 

 

Reset Pin

 

RED Low Battery

 

P

 

 

 

 

Disable All Except Battery

 

 

 

Reference Manual #74-06144-000 figure #19 For Wiring Diagram

Charging And Local Programming

 

 

 

Reference Document #73-06143-000 for Compatible Smoke Detectors

 

 

 

1

 

 

32

 

 

2

 

 

31

 

 

 

 

 

INTERFACE

 

 

 

 

 

 

 

UP TO 63

 

 

 

 

 

 

D8126 U/T OR

 

 

 

 

 

 

D8127 U/T

 

 

 

 

 

 

POPITS

D8125 POPEX 1

 

 

 

 

 

IN

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page

Operation &

65

Installation

D126

BATTERY 12V 7Ah

D126

BATTERY 12V 7Ah

LISTED

AUDIBLE SIGNALING DEVICES RATED AT 10.2 TO 13.8 VDC (DO NOT USE VIBRATING TYPE HORNS)

D192A

AUX PWR

ALARM TRIG

COM

SUPV IN

ALARM CKT

P +

- P

SS

J 3 P

S

D128

 

P

S

P

 

S

 

TO RJ31X FOR

PRIMARY

PHONE LINE

P

3

 

 

 

 

30

 

 

 

4

 

 

 

 

29

 

 

 

5

 

 

 

 

28

P S

 

 

6

 

 

 

 

27

P

S

 

 

 

 

 

 

 

 

7

 

 

 

 

26

P

S

 

8

 

 

 

 

25

 

P S

 

 

 

 

 

 

 

 

9

 

 

 

 

24

P

 

 

10

 

 

 

 

23

P

 

 

LINE SNIFFER SELECT

 

 

 

 

 

 

 

 

Loop Start

 

 

 

 

 

 

 

 

Ground Start

 

 

 

PROG

 

 

 

 

 

 

 

 

CONN

 

 

 

TELCO

GROUND

RED PHONE

 

 

 

 

 

 

CORD

START

LED

 

 

EXP

 

 

 

 

Requires

 

 

 

 

 

 

 

Relay

 

 

 

PORT

 

 

 

MODEL No.

#D136

ON WHEN

11

12

13 14 15 16 17 18 19 20 21 22

 

 

 

COMMUNICATING

 

 

 

D161

In J5

OFF WHEN IDLE

 

 

 

 

 

 

 

 

D105 FL

EOL DEVICE

(FOR TYPICAL BURGLAR ALARM APPLICATIONS)

 

GND AUX OUT

+

 

 

 

 

 

CONNECT UP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO EIGHT

 

 

 

 

 

 

 

 

 

 

 

 

OCTORELAYS

 

 

 

 

 

 

DATA AUX GND

 

OR D811 ARM STATUS RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UP TO 63

 

 

 

 

 

 

 

D8129

 

 

 

 

 

 

 

 

D8126 U/T OR

 

 

 

 

 

 

OCTORELAY

 

D8127 U/T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POPITS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN OUT AUX GND

-

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D8125 POPEX 2

 

 

 

 

 

 

 

CONNECT UP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO EIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OCTORELAYS

 

 

 

 

 

 

 

 

AUX GND

DATA

Manual

© 1993-1996 Radionics

ECL DEVICE 15-03130-001

TO RJ31X FOR

SECONDARY

PHONE LINE

P= POWER LIMITED

S= SUPERVISED

1 10 3 4 2 or 5

D125

P - + - + P

SS

LOOP B

6 7 5 8 9

1

2

3D129

4

10 11 12 13

L

O

O

P

A

 

TYPICAL INITIATING DEVICES ARE

D105 FL EOL

DOOR CONTACTS NO/NC, FLOOR

MATS, MOTION SENSORS, GLASS

DEVICE

BREAK DETECTORS, ETC.

 

SUITABLE FOR VALVE TAMPER

AND OTHER TYPES OF

EXTINGUISHING SYSTEM

SUPERVISION.

D129 PROVIDES OPTIONAL WATERFLOW ALARM RETARD FEATURE. NOT SUITABLE FOR 2-WIRE SMOKE DETECTORS. NOTE: USE ZERO RETARD EXCEPT FOR WATERFLOW.

D8128A OCTORELAY

OR D811 ARM STATUS RELAY

System Wiring Diagram, Issue A

Page 65
Image 65
Bosch Appliances D9112 installation manual System Wiring Diagram, Issue a